Evaluation of the Bio-Rad BioPlex 2200 Syphilis Multiplex Flow Immunoassay for the Detection of IgM- and IgG-Class Antitreponemal Antibodies
Authors:
- 1 June 2010
- journal article
- research article
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 17 (6) , 966-968
Abstract
The laboratory diagnosis of syphilis is based primarily upon serologic findings. Historically, serologic testing for syphilis has relied on assays such as rapid plasma reagin, fluorescent treponemal antibody absorption, Treponema pallidum particle agglutination (TP-PA), and more recently, enzyme immunoassay (EIA). In this study, we evaluated the performance of a novel multiplex flow immunoassay (BioPlex 2200 Syphilis; Bio-Rad Laboratories, Hercules, CA) for the detection of antitreponemal IgG- and IgM-class antibodies. Serum specimens ( n = 1,008) submitted for routine treponema-specific antibody testing by syphilis IgM and IgG EIA (Trep-Chek; Phoenix-Biotech, Mississauga, Ontario, Canada) were also analyzed by the BioPlex Syphilis multiplex assay. Specimens showing discordant results were repeat tested, with further discrepancies being arbitrated by TP-PA. Compared directly to the results of EIA, the BioPlex IgG assay demonstrated 98.7% (77/78) sensitivity and 99.4% (916/930) specificity. Compared to the Trep-Chek IgM EIA, the BioPlex IgM assay showed 80% (4/5) sensitivity and 97.9% (652/666) specificity. These results indicate that the BioPlex Syphilis multiplex assay shows similar serological agreement with EIA while allowing for a fully automated random-access platform that provides faster (1.7 h for 100 samples versus 4.5 h by EIA) and higher-throughput (800 samples per 9 h versus 200 samples by EIA) analysis of the syphilis serologic response.Keywords
This publication has 20 references indexed in Scilit:
- Evaluation of Three Multiplex Flow Immunoassays Compared to an Enzyme Immunoassay for the Detection and Differentiation of IgG Class Antibodies to Herpes Simplex Virus Types 1 and 2Clinical and Vaccine Immunology, 2010
- The Architect Syphilis assay for antibodies to Treponema pallidum: an automated screening assay with high sensitivity in primary syphilisSexually Transmitted Infections, 2009
- Evaluation of a Multiplex Flow Immunoassay for Detection of Epstein-Barr Virus-Specific AntibodiesClinical and Vaccine Immunology, 2008
- Comparative evaluation of 15 serological assays for the detection of syphilis infectionEuropean Journal of Clinical Microbiology & Infectious Diseases, 2007
- Cytometric bead array: a multiplexed assay platform with applications in various areas of biologyClinical Immunology, 2004
- Evaluation of a Treponema pallidum-Specific IgM Enzyme Immunoassay and Treponema pallidum Western Blot Antibody Detection in the Diagnosis of Maternal and Congenital SyphilisSexually Transmitted Diseases, 2004
- Evaluation of an Enzyme Immunoassay Technique for Detection of Antibodies against Treponema pallidumJournal of Clinical Microbiology, 2003
- Evaluation of an enzyme immunoassay for IgM antibodies to Treponema pallidum in syphilis in man.Sexually Transmitted Infections, 1984
- The pattern of immunological responses at various stages of syphilis.Sexually Transmitted Infections, 1977
- IgM class antitreponemal antibody in treated and untreated syphilis.Sexually Transmitted Infections, 1972