We developed a Bayesian spline model for real-time mass concentrations of particulate matter (PM10, PM2.5, PM1, and PM0.3) measured simultaneously in the personal breathing zone of Parisian subway workers. The measurements were performed by GRIMM, a gravimetric method, and DiSCmini during the workers’ work shifts over two consecutive weeks. The measured PM concentrations were analyzed with respect to the working environment, the underground station, and any specific events that occurred during the work shift. Overall, PM0.3 concentrations were more than an order of magnitude lower compared to the other PM concentrations and showed the highest temporal variation. The PM2.5 levels raised the highest exposure concern: 15 stations out of 37 had higher mass concentrations compared to the reference. Station PM levels were not correlated with the annual number of passengers entering the station, the year of station opening or renovation, or the number of platforms and tracks. The correlation with the number of station entrances was consistently negative for all PM sizes, whereas the number of correspondence concourses was negatively correlated with PM0.3 and PM10 levels and positively correlated with PM1 and PM2.5 levels. The highest PM10 exposure was observed for the station platform, followed by the subway cabin and train, while ticket counters had the highest PM0.3, PM1, and PM2.5 mass concentrations. We further found that compared to gravimetric and DiSCmini measurements, GRIMM results showed some discrepancies, with an underestimation of exposure levels. Therefore, we suggest using GRIMM, calibrated by gravimetric methods, for PM sizes above 1μm, and DiSCmini for sizes below 700 nm.Keywords
Funding Information
- Swiss National Science Foundation (IZCOZ0_177067 “ROBoCoP”)
This publication has 40 references indexed in Scilit:
- Inter-comparison of personal monitors for nanoparticles exposure at workplaces and in the environmentScience of The Total Environment, 2017
- Review of measurement techniques and methods for assessing personal exposure to airborne nanomaterials in workplacesScience of The Total Environment, 2017
- Factors controlling particle number concentration and size at metro stationsAtmospheric Environment, 2017
- Preliminary investigation of PM1, PM2.5, PM10 and its metal elemental composition in tunnels at a subway station in Shanghai, ChinaTransportation Research Part D: Transport and Environment, 2015
- Exposure to airborne particulate matter in the subway systemScience of The Total Environment, 2015
- Physicochemical Characterization of Airborne Particulate Matter at a Mainline Underground Railway StationEnvironmental Science & Technology, 2013
- Comparison of the DiSCmini Aerosol Monitor to a Handheld Condensation Particle Counter and a Scanning Mobility Particle Sizer for Submicrometer Sodium Chloride and Metal AerosolsJournal of Occupational and Environmental Hygiene, 2013
- Characterizing the performance of two optical particle counters (Grimm OPC1.108 and OPC1.109) under urban aerosol conditionsJournal of Aerosol Science, 2010
- Measurement of Particle Mass Concentrations and Size Distributions in an Underground StationAerosol and Air Quality Research, 2010
- Comparison of the TSI Model 8520 and Grimm Series 1.108 Portable Aerosol Instruments Used to Monitor Particulate Matter in an Iron FoundryJournal of Occupational and Environmental Hygiene, 2008