Nanophthalmos: quantitative analysis of anterior chamber angle configuration before and after cataract surgery
Authors:
- Masaaki SekiMSMasaaki Seki
- Takeo FukuchiTFTakeo Fukuchi
- Jun UedaJUJun Ueda
- Kieko SudaKSKieko Suda
- Tomoko NakatsueTNTomoko Nakatsue
- Yoko TanakaYTYoko Tanaka
- Tetsuya ToganoTTTetsuya Togano
- Susumu YamamotoSYSusumu Yamamoto
- Hiroaki HaraHHHiroaki Hara
- Haruki AbeHAHaruki Abe
- 2 June 2012
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 96 (8) , 1108-1116
Abstract
To analyse quantitatively the anterior segment configuration in eyes with nanophthalmos before and after cataract surgery. This was a retrospective, non-comparative, interventional case series. Eleven eyes in eight patients with nanophthalmos who underwent phacoemulsification and intraocular lens implantation were identified from the department's surgical log, and their clinical records were retrospectively reviewed. Main outcome measures were as follows: visual acuity, intraocular pressure (IOP), axial length and the following ultrasound biomicroscopy parameters: angle opening distance at 500 μm anterior to the scleral spur (AOD500), trabecular-iris angle (TIA) and trabecular ciliary process distance. The mean axial length of the eyes was 17.3 ± 1.7 mm. AOD500 and TIA increased after cataract surgery (p<0.005). Smaller axial length, AOD500 and TIA before cataract surgery were observed in eyes with preoperative IOP elevation than those without preoperative IOP elevation (p<0.05). Lower postoperative IOP was correlated with greater AOD500 and TIA before cataract surgery (p<0.05). Cataract surgery deepened the anterior chamber and widened the anterior chamber angle in nanophthalmic eyes. Cataract surgery may have beneficial effects on IOP in eyes with nanophthalmos.Keywords
This publication has 10 references indexed in Scilit:
- Phacoemulsification in patients with nanophthalmosCanadian Journal of Ophthalmology, 2009
- Prospective comparison of ultrasound biomicroscopy and anterior segment optical coherence tomography for evaluation of anterior chamber dimensions in European eyes with primary angle closureEye, 2009
- A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology following laser iridotomy in European eyesEye, 2009
- Nanophthalmos: Ultrasound biomicroscopy and Pentacam assessment of angle structures before and after cataract surgeryJournal of Cataract & Refractive Surgery, 2006
- Comparison of ultrasound biomicroscopic parameters after laser iridotomy in eyes with primary angle closure and primary angle closure glaucomaEye, 2006
- Cataract Surgery in the Small Adult EyeSurvey of Ophthalmology, 2006
- Angle Widening and Alteration of Ciliary Process Configuration after Cataract Surgery for Primary Angle ClosureOphthalmology, 2006
- Cataract surgery in patients with nanophthalmosJournal of Cataract & Refractive Surgery, 2004
- Angle closure in younger patientsOphthalmology, 2003
- NANOPHTHALMOS - A PERSPECTIVE ON IDENTIFICATION AND THERAPY1982