Influence of Acquisition Time on MR Image Quality Estimated with Nonparametric Measures Based on Texture Features
Open Access
- 20 November 2019
- journal article
- research article
- Published by Wiley in BioMed Research International
- Vol. 2019, 1-10
Abstract
Correlation of parametrized image texture features (ITF) analyses conducted in different regions of interest (ROIs) overcomes limitations and reliably reflects image quality. The aim of this study is to propose a nonparametrical method and classify the quality of a magnetic resonance (MR) image that has undergone controlled degradation by using textural features in the image. Images of 41 patients, 17 women and 24 men, aged between 23 and 56 years were analyzed. T2-weighted sagittal sequences of the lumbar spine, cervical spine, and knee and T2-weighted coronal sequences of the shoulder and wrist were generated. The implementation of parallel imaging with the use of GRAPPA2, GRAPPA3, and GRAPPA4 led to a substantial reduction in the scanning time but also degraded image quality. The number of degraded image textural features was correlated with the scanning time. Longer scan times correlated with markedly higher ITF image persistence in comparison with images computed with reduced scan times. Higher ITF preservation was observed in images of bones in the spine and femur as compared to images of soft tissues, i.e., tendons and muscles. Finally, a nonparametrized image quality assessment based on an analysis of the ITF, computed for different tissues, correlating with the changes in acquisition time of the MR images, was successfully developed. The correlation between acquisition time and the number of reproducible features present in an MR image was found to yield the necessary assumptions to calculate the quality index.Keywords
Funding Information
- Akademia Górniczo-Hutnicza im. Stanislawa Staszica (16.16.120.773)
This publication has 52 references indexed in Scilit:
- Computerised analysis of osteoporotic bone patterns using texture parameters characterising bone architectureBritish Journal of Radiology, 2013
- Texture analysis of MR images of patients with Mild Traumatic Brain InjuryBMC Medical Imaging, 2010
- Automatic quality assessment in structural brain magnetic resonance imagingMagnetic Resonance in Medicine, 2009
- The impact of image dynamic range on texture classification of brain white matterBMC Medical Imaging, 2008
- Automated quality control of brain MR imagesJournal of Magnetic Resonance Imaging, 2008
- Application of reinforcement learning for segmentation of transrectal ultrasound imagesBMC Medical Imaging, 2008
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- A distortion measure for blocking artifacts in images based on human visual sensitivityIEEE Transactions on Image Processing, 1995
- Analysis of the eddy-current induced artifacts and the temporal compensation in nuclear magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991
- Estimation and choice of neighbors in spatial-interaction models of imagesIEEE Transactions on Information Theory, 1983