Effect of eyelid manipulation and manual jugular compression on intraocular pressure measurement in dogs
Authors:
- Sheryl G. KrohneSKSheryl G. Krohne
- George E. MooreGMGeorge E. Moore
- Ahmed S. MohamedAMAhmed S. Mohamed
- Jean StilesJSJean Stiles
- 15 May 2011
- journal article
- research article
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 238 (10) , 1292-1295
Abstract
Objective—To determine the effect of eyelid manipulation and manual jugular compression on intraocular pressure (IOP) measurement in clinically normal dogs. Design—Randomized clinical trial. Animals—30 dogs (57 eyes) without diseases or medications that affect IOP. Procedures—An applanation tonometer was used to measure IOP during eyelid manipulation or jugular compression. Six manipulations were used in each eye, including minimal eyelid manipulation, maximal dorsoventral extension of the eyelids, lateral eyelid extension, manual compression of the ipsilateral jugular vein, manual compression of both jugular veins, and lateral eyelid extension with manual compression of both jugular veins. Skull type and position of globe in the orbit were recorded. Results—The 2 manipulations that caused the greatest significant increase in mean IOP were lateral eyelid extension with compression of both jugular veins (difference from baseline IOP, 17.6 mm Hg; 95% confidence interval [CI], 15.7 to 19.5 mm Hg) and lateral eyelid extension alone (16.5 mm Hg; 95% CI, 14.6 to 18.4 mm Hg). Dorsoventral eyelid extension (6.42 mm Hg; 95% CI, 4.5 to 8.3 mm Hg) and compression of both jugular veins alone (3.0 mm Hg; 95% CI, 1.1 to 5.0 mm Hg) significantly increased mean IOP, compared with baseline. Compression of the ipsilateral jugular vein increased mean IOP (0.3 mm Hg; 95% CI, −1.6 to 2.2 mm Hg) from baseline, but not significantly. Conclusions and Clinical Relevance—Traction on the eyelids or pressure on both jugular veins can significantly increase IOP values as measured by use of applanation tonometry in clinically normal dogs.Keywords
This publication has 12 references indexed in Scilit:
- Effect of body position on intraocular pressure in dogs without glaucomaAmerican Journal of Veterinary Research, 2008
- Effects of the Application of Neck Pressure by a Collar or Harness on Intraocular Pressure in DogsJournal of the American Animal Hospital Association, 2006
- Evaluation of a rebound tonometer for measuring intraocular pressure in dogs and horsesJournal of the American Veterinary Medical Association, 2005
- Duration of effect and effect of multiple doses of topical ophthalmic 0.5% proparacaine hydrochloride in clinically normal dogsAmerican Journal of Veterinary Research, 2005
- Impact factors on intraocular pressure measurements in healthy subjectsBritish Journal of Ophthalmology, 2004
- Effect of a tight necktie on intraocular pressureBritish Journal of Ophthalmology, 2003
- Attempted eyelid closure affects intraocular pressure measurementAmerican Journal of Ophthalmology, 2001
- Increased intraocular pressure and visual field defects in high resistance wind instrument playersOphthalmology, 2000
- Distribution of intraocular pressure in dogsVeterinary Ophthalmology, 1998
- Glaucoma With Elevated Episcleral Venous PressureSouthern Medical Journal, 1975