Reducing analytical variation between point-of-care and laboratory HbA1c testing (减少HbA1c的床边检验与实验室检验之间的分析变异)
Authors:
- 4 October 2012
- journal article
- research article
- Published by Wiley in Journal of Diabetes
- Vol. 5 (2) , 192-196
Abstract
Background Point-of-care (POC) HbA1c testing allows for timely treatment changes, improved glycemic control, and patient and provider satisfaction. Substantial variation between POC and laboratory HbA1c results has been reported. At our university hospital diabetes clinic, we observed significant negative bias in HbA1c with the DCA Vantage™ (Siemens Healthcare Diagnostics, Tarrytown, NY, USA) compared with the Tosoh G8 HPLC laboratory analyzer (Tosoh Bioscience, San Francisco, CA, USA). This led us to systematically analyze the bias with the goal of recalibrating the DCA to minimize bias. Methods We analyzed 45 patient samples, with HbA1c ranging between 5% and 10.8%, concurrently on two DCA analyzers and on the Tosoh G8 machine. The bias for each sample was the difference between the value on the DCA and the Tosoh G8 analyzer. Based on regression equations derived from the data, a correction factor for each DCA analyzer was calculated. The analyzers were recalibrated and retested for bias. Results At baseline, the mean bias (range) was −0.5229 (+0.1 to −1.3) for Analyzer 1 and −0.5348 (0.0 to −1.6) for Analyzer 2. After recalibration, the mean bias (range) was 0.000 (+0.6 to −0.6) and 0.0003 (+0.5 to −0.5) for Analyzers 1 and 2, respectively, and the systematic negative bias seen prior to the calibration was almost eliminated. Conclusions We recommend periodic recalibration of POC analyzers to eliminate systematic unidirectional bias and to harmonize results between the POC and central laboratory analyzers within a healthcare system. Calibration may need to be repeated with any change in the reagent lot.Keywords
This publication has 19 references indexed in Scilit:
- Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes MellitusClinical Chemistry, 2011
- Evaluation of two HbA1c point-of-care analyzersClinical Chemistry and Laboratory Medicine (CCLM), 2011
- Hemoglobin A1c: Assessment of three POC analyzers relative to a central laboratory methodClinica Chimica Acta, 2010
- Utility of immediate hemoglobin A1c in children with type I diabetes mellitusPediatric Diabetes, 2010
- Six of Eight Hemoglobin A1c Point-of-Care Instruments Do Not Meet the General Accepted Analytical Performance CriteriaClinical Chemistry, 2010
- Few Point-of-Care Hemoglobin A1c Assay Methods Meet Clinical NeedsClinical Chemistry, 2010
- Point of care testing to improve glycemic controlInternational Journal of Health Care Quality Assurance, 2008
- Analytic Bias Among Certified Methods for the Measurement of Hemoglobin A1cAmerican Journal of Clinical Pathology, 2008
- Effect of Point-of-Care on Maintenance of Glycemic Control as Measured by A1CDiabetes Care, 2007
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusThe New England journal of medicine, 1993