Autograft versus sterilized allograft for lateral calcaneal lengthening osteotomies
Authors:
- Sebastian A. MüllerSMSebastian A. Müller
- Alexej BargABAlexej Barg
- Patrick VavkenPVPatrick Vavken
- Victor ValderrabanoVVVictor Valderrabano
- Andreas M. MüllerAMAndreas M. Müller
Open Access
- 1 July 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 95 (30) , e4343
Abstract
Sterilized allografts may be less resistant to collapse and prone to nonunion leading to loss of correction in open wedge osteotomies. These adverse events usually occur at early time points (i.e., < 9 months postoperatively). The goal of this study was to compare sterilized allografts to autologous grafts in respect to secondary loss of hindfoot alignment and graft incorporation after lateral calcaneal lengthening osteotomies. Fifty patients (22 F/ 28 M, age: 16–69 years) who had undergone 50 lateral calcaneal lengthening osteotomies for adult flatfoot deformity were included in this retrospective study. Cortical sterilized allografts were used in 25 patients, autologous grafts in the remaining 25. Patients’ preoperative, 6 and 12 weeks, and 6 to 9 months follow-up weight-bearing radiographs of the affected foot were analyzed by 2 blinded radiologists: on each radiograph, graft incorporation, the talo-first metatarsal angle (TFMA), the talo-navicular coverage angle (TNCA), and the calcaneal pitch angle (CPA) were assessed. Loss of hindfoot alignment was defined as an increase of the TFMA or the TNCA or a decrease of the CPA, each by 5°. Inter- and intraclass correlation coefficients for TFMA, TNCA, and CPA measurements ranged from 0.93 to 0.99. At all follow-up visits, the ratio of patients with loss of hindfoot alignment and graft incorporation was not significantly different between the allograft and autograft group. However, loss of correction was associated with failure of graft incorporation. Compared with autografts, sterilized allografts do not increase the risk for loss of hindfoot alignment in lateral column lengthening of the calcaneus. With respect to mechanical resistance, allografts thus mean an equal and valid alternative without risk of donor site morbidities.Keywords
This publication has 39 references indexed in Scilit:
- Substitutes of structural and non-structural autologous bone grafts in hindfoot arthrodeses and osteotomies: a systematic reviewBMC Musculoskeletal Disorders, 2013
- A protocol for classifying normal‐ and flat‐arched foot posture for research studies using clinical and radiographic measurementsJournal of Foot and Ankle Research, 2009
- Impact of MHC mismatch and freezing on bone graft incorporation: An experimental study in ratsJournal of Orthopaedic Research, 2008
- Use of Allograft in Skeletally Immature Patients for Calcaneal Neck Lengthening OsteotomyYonsei Medical Journal, 2008
- Sterilization of allograft bone: effects of gamma irradiation on allograft biology and biomechanicsCell and Tissue Banking, 2006
- The Clinical Use of Allografts, Demineralized Bone Matrices, Synthetic Bone Graft Substitutes and Osteoinductive Growth Factors: A Survey StudyHSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery, 2005
- A review of osteoinductive testing methods and sterilization processes for demineralized boneCell and Tissue Banking, 2005
- Wert der peripheren quantitativen Computertomographie (pQCT) in der OsteoporosediagnostikZeitschrift für Orthopädie und ihre Grenzgebiete, 2003
- Validation of the Sterilization Procedure of Allogeneic Avital Bone Transplants Using Peracetic Acid–EthanolBiologicals, 2001
- Complications of Iliac Crest Bone Graft HarvestingClinical Orthopaedics and Related Research, 1996