Implementation and Clinical Application of 24-Hour Intraocular Pressure Monitoring in China: A Nationwide Survey
Authors:
- Mengyuan HuMHMengyuan Hu
- Tong LiuTLTong Liu
- Ke YaoKYKe Yao
- Zongrong WangZWZongrong Wang
- Min ChenMCMin Chen
- Kaijun WangKWKaijun Wang
Open Access
- 1 February 2026
- journal article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-11
Abstract
To evaluate the nationwide implementation and clinical application of 24-hour intraocular pressure (IOP) monitoring in China. A nationwide descriptive cross-sectional study was conducted from September 2024 to March 2025. Two structured questionnaires were distributed to 467 hospitals across China (400 valid responses) and 170 patients recruited from our institution who were undergoing 24-hour IOP monitoring for the first time. Collected data included implementation rates, tonometer types, measurement protocols, examiner consistency, and patient-reported perceptions. Among the 400 responding hospitals, 261 (65.3%) had implemented 24-hour IOP monitoring; however, 85.1% managed fewer than 20 patients per month. The most common measurement frequencies within a 24-hour period were 12 (37.2%), 6 (32.6%), and 7 times (27.2%), respectively. Non-contact tonometer (NCT) was the predominant device for both daytime (67.8%) and nighttime (64.6%) measurements. Among the 175 hospitals performing nocturnal measurements, only 7.4% employed supine positioning. In 65.5% of institutions, 24-hour IOP measurements for individual patients were performed by multiple nurses. Regarding patient perceptions, 95.8% considered 24-hour IOP monitoring important, yet 52.9% expressed reluctance to undergo the repeated procedure, citing hospitalization inconvenience (80%), sleep disruption (28.9%), concerns about measurement accuracy (4.4%), and cost (4.4%). Although over half of the surveyed hospitals had implemented 24-hour IOP monitoring, overall clinical utilization remained suboptimal, with highly heterogeneous local protocols and considerable patient reluctance toward the current inpatient-based, nurse-dependent monitoring paradigm. Standardized implementation of national guidelines, enhanced patient education, and development of patient-centric, wearable IOP monitoring technologies are essential to optimize accessibility and support glaucoma management.Keywords
This publication has 29 references indexed in Scilit:
- Ptosis Crutches: An Eye Opening SolutionOphthalmology, 2024
- Relative corneal refractive power shift and inter-eye differential axial growth in children with myopic anisometropia treated with bilateral orthokeratologyGraefe's Archive for Clinical and Experimental Ophthalmology, 2023
- Effect of Different Postures on Intraocular Pressure in Open-Angle GlaucomaOphthalmology and Therapy, 2023
- Glaucoma: now and beyondThe Lancet, 2023
- Role of ocular blood flow in normal tension glaucomaAdvances in Ophthalmology Practice and Research, 2022
- Questionnaire survey on complications during 24-h measurement of intraocular pressure-related patterns with a contact lens sensorInternational Ophthalmology, 2020
- Review of the measurement and management of 24-hour intraocular pressure in patients with glaucomaSurvey of Ophthalmology, 2020
- Diurnal and 24-h Intraocular Pressures in Glaucoma: Monitoring Strategies and Impact on Prognosis and TreatmentAdvances in Therapy, 2018
- GlaucomaThe Lancet, 2017
- Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040Ophthalmology, 2014