Computer-Simulation Technique for Low Dose Computed Tomographic Screening
Authors:
- Kouzou HanaiKHKouzou Hanai
- Tetsuya HoriuchiTHTetsuya Horiuchi
- Junko SekiguchiJSJunko Sekiguchi
- Yoshihisa MuramatsuYMYoshihisa Muramatsu
- Ryutaro KakinumaRKRyutaro Kakinuma
- Noriyuki MoriyamaNMNoriyuki Moriyama
- Ryosuke TuchiiyaRTRyosuke Tuchiiya
- Noboru NikiNNNoboru Niki
- 1 November 2006
- journal article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 30 (6) , 955-961
Abstract
The purpose of this study is to assess the relative influence of noise and artifact in detecting lung nodules on low dose computed tomographic (CT) screening. We develop the computer-simulation technique that allows tube current simulation and virtual nodule insertion in any CT images. The tube current simulation uses a reduction model that adds random Gaussian noise distribution to existing projection data. The virtual nodules are generated using a dedicated CT simulation tool with same scanner geometry. The coefficient of the correlations between the contrast-to-noise ratio of the actual scan and simulated tube current images was 0.98. There was no difference in CT number between virtual nodules and actual nodules [t test results = 0.60, t50(0.01) = 2.70 at 10 mA] and the coefficient of the correlations of the image noise was 0.99. Our technique is useful for systematic evaluation of radiation dose reduction and structure visibility in low-dose CT screening.Keywords
This publication has 14 references indexed in Scilit:
- Progression of Focal Pure Ground-Glass Opacity Detected by Low-Dose Helical Computed Tomography Screening for Lung CancerJournal of Computer Assisted Tomography, 2004
- Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countriesThe Lancet, 2004
- CT Screening for Lung CancerAmerican Journal of Roentgenology, 2002
- Computed tomography screening for lung carcinoma in JapanCancer, 2000
- Adaptive streak artifact reduction in computed tomography resulting from excessive x‐ray photon noiseMedical Physics, 1998
- Mass screening for lung cancer with mobile spiral computed tomography scannerThe Lancet, 1998
- Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography.Radiology, 1996
- Small adenocarcinoma of the lung. Histologic characteristics and prognosisCancer, 1995
- Performance of evaluation of computed tomography scanners using a phantom modelAmerican Journal of Roentgenology, 1979
- Anthropomorphic Phantoms for Computed Tomography Scanner Performance EvaluationJournal of Computer Assisted Tomography, 1978