A highly selective and sensitive chemosensor forl-tryptophan by employing a Schiff based Cu(ii) complex
- 18 January 2018
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 42 (5) , 3509-3518
Abstract
A new Cu(II) complex C40H38N4CuO2 (1) was synthesized and characterized by elemental analysis, mass spectrometry and also authenticated by single crystal X-ray studies. Structural analysis of 1 reveals the distorted square planar geometry around the Cu(II) centre and the presence of C–H⋯O and N–H⋯π hydrogen bonding interactions. The sensing behaviour of 1 towards L-tryptophan (L-Trp) was identified by UV-vis spectroscopic and cyclic voltammetry experiments. In the UV titration of 1 with L-Trp, four distinct isosbestic points were observed. Furthermore, on modifying the surface of the glassy carbon electrode (GCE) by 1 (1-GCE) the oxidation potential of L-Trp at +0.32 V is revealed, which is considerably lower than the values previously reported for other electrodes. Additionally, the 1-GCE can detect L-Trp with a noteworthy detection limit (185 nM), sensitivity (3.156 μA μM−1 cm−2) and with distinguished selectivity in the presence of various other amino acids. The 1-GCE also displays excellent reproducibility, repeatability and long term stability. Finally, electrochemical impedance spectroscopy (EIS) investigations were carried out to gauge the effects of modification with 1 on the characteristics of the GCE. Moreover, the molecular docking study of 1 with various proteins reveals the π–π stacking interaction with L-Trp.Keywords
Funding Information
- Anusandhan National Research Foundation (EMR/2016/001113)
- University Grants Commission
- Ministry of Human Resource Development
This publication has 66 references indexed in Scilit:
- Electrochemical determination of L-Tryptophan based on a multiwall carbon nanotube/Mg–Al layered double hydroxide modified carbon paste electrode as a sensorJournal of Electroanalytical Chemistry, 2013
- A sensitive sensor for determination of l-tryptophan based on gold nanoparticles/poly(alizarin red S)-modified glassy carbon electrodeJournal of Solid State Electrochemistry, 2013
- Biomimetic sensor for certain catecholamines employing copper(II) complex and silver nanoparticle modified glassy carbon paste electrodeBiosensors and Bioelectronics, 2013
- Phosphorescent Sensor for Robust Quantification of Copper(II) IonJournal of the American Chemical Society, 2011
- A rapid and highly selective colorimetric method for direct detection of tryptophan in proteins via DMSO accelerationChemical Communications, 2011
- Simultaneous determination of levodopa, NADH, and tryptophan using carbon paste electrode modified with carbon nanotubes and ferrocenedicarboxylic acidJournal of Solid State Electrochemistry, 2010
- Effects of tryptophan loading on human cognition, mood, and sleepNeuroscience & Biobehavioral Reviews, 2010
- Crystal structure of the polymerase PAC–PB1N complex from an avian influenza H5N1 virusNature, 2008
- Relationship between grain‐boundary capacitance and bulk shallow donors in SnO2 polycrystalline semiconductorPhysica Status Solidi (a), 2008
- A short history of SHELXActa Crystallographica Section A Foundations of Crystallography, 2007