Implantable Intracranial Pressure Sensor with Continuous Bluetooth Transmission via Mobile Application
Open Access
- 28 August 2023
- journal article
- research article
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 13 (9) , 1318
Abstract
Hydrocephalus is a clinical disorder caused by excessive cerebrospinal fluid (CSF) buildup in the ventricles of the brain, often requiring permanent CSF diversion via an implanted shunt system. Such shunts are prone to failure over time; an ambulatory intracranial pressure (ICP) monitoring device may assist in the detection of shunt failure without an invasive diagnostic workup. Additionally, high resolution, noninvasive intracranial pressure monitoring will help in the study of diseases such as normal pressure hydrocephalus (NPH) and idiopathic intracranial hypertension (IIH). We propose an implantable, continuous, rechargeable ICP monitoring device that communicates via Bluetooth with mobile applications. The design requirements were met at the lower ICP ranges; the obtained error fell within the idealized ±2 mmHg margin when obtaining pressure values at or below 20 mmHg. The error was slightly above the specified range at higher ICPs (±10% from 20–100 mmHg). The system successfully simulates occlusions and disconnections of the proximal and distal catheters, valve failure, and simulation of A and B ICP waves. The mobile application accurately detects the ICP fluctuations that occur in these physiologic states. The presented macro-scale prototype is an ex-vivo model of an implantable, rechargeable ICP monitoring system that has the potential to measure clinically relevant ICPs and wirelessly provide accessible and continuous data to aid in the workup of shunt failure.Keywords
This publication has 28 references indexed in Scilit:
- B-waves revisitedInterdisciplinary Neurosurgery, 2016
- Telemetric Intracranial Pressure Monitoring with the Raumedic Neurovent P-telWorld Neurosurgery, 2016
- Shunt Devices for the Treatment of Adult Hydrocephalus: Recent Progress and CharacteristicsNeurologia medico-chirurgica, 2016
- Advances in Intracranial Pressure Monitoring and Its Significance in Managing Traumatic Brain InjuryInternational Journal of Molecular Sciences, 2015
- A Bluetooth-based Low-Energy Qi-compliant battery charger for implantable medical devices2014
- Overview and Evaluation of Bluetooth Low Energy: An Emerging Low-Power Wireless TechnologySensors, 2012
- Review: Semiconductor Piezoresistance for MicrosystemsProceedings of the IEEE, 2009
- Monitoring and interpretation of intracranial pressureJournal of Neurology, Neurosurgery & Psychiatry, 2004
- RAISED INTRACRANIAL PRESSUREJournal of Neurology, Neurosurgery & Psychiatry, 2002
- A New Ventriculoperitoneal Shunt with a Telemetric Intracranial Pressure Sensor: Clinical Experience in 94 Patients with HydrocephalusNeurosurgery, 1997