Abstract
The sound produced by an organ pipe results from a strong coupling between the pipe and its wind supply system, which governs both steady-state characteristics and transient behaviour. While detailed models of organ wind systems exist, their complexity and large number of parameters hinder their practical use and obscure the link between these parameters and the observed behaviours. This study investigates to what extent a simplified one-dimensional model can reproduce and explain the evolution of supply pressure in a real pipe organ, and how far such a model can be reduced while preserving the essential dynamics. Pressure measurements were carried out at several locations in an organ wind system, using a robotic key-actuation device to maximise repeatability. These measurements were compared with simulations of a reduced lumped-parameter model based on interconnected cavities and channels. A “three cavity – three channel” formulation is proposed, characterised by a small set of physically interpretable time constants. The model successfully reproduces the measured steady pressures and transient rising times for all pipes, highlighting its ability to interpret experimental data and make the link between model parameters and observed behaviour. Some limitations are discussed: the assumption that the pressure is homogeneous in cavities and the lack of link between effective and geometric parameters.
Funding Information
  • Sorbonne Université (ISCD, FED 3-2019/7/2)
  • Joint Programming Initiative on Cultural Heritage (The Past Has Ears, Grant No. 20-JPIC-0002- FS)
  • Agence Nationale de la Recherche (ANR- 20 20-CE38-0014)

This publication has 11 references indexed in Scilit: