Radiographic, Histologic, and Chemical Evaluation of Bioresorbable 70/30 Poly-L-lactide-CO-D, L-lactide Interbody Fusion Cages in a Goat Model
- 15 June 2006
- journal article
- basic science
- Published by Wolters Kluwer Health in Spine
- Vol. 31 (14) , 1559-1567
Abstract
Study Design. A study of lumbar interbody fusion using polylactic acid-based bioresorbable fusion cages in a goat model. Objective. To evaluate the effect of polylactic acid polymer composition, and internal stabilization on the rate and quality of interbody fusion. Summary of Background Data. A spinal cage should provide an appropriate biomechanical environment to facilitate interbody fusion. Previous studies have shown that bioresorbable polylactic acid-based cages can provide adequate stability for spinal fusion. However, at present and to our knowledge, the best bioresorbable materials, optimal cage stiffness, and desired period over which the cage should biodegrade are unknown. Methods. Interbody fusions were performed at L3–L4 level in 35 skeletally mature Dutch milk goats. Titanium and poly-L-lactide-CO-D,L-lactide (PLDLLA) cages were implanted at random as stand-alone cages. In addition, PLDLLA cages were implanted with anterior fixation. The goats were euthanized at 3, 6, or 12 months. Radiographic, magnetic resonance imaging, histologic, and histomorphometric analyses were performed on retrieved segments. Chemical analysis was used to assess degradation of the retrieved PLDLLA cages. Beforehand, chemical and mechanical degradation of the PLDLLA cages were assessed in vitro. Results. At 3 months, bone graft was almost completely remodeled. Endochondral bone formation was observed in all specimens. At 6 months, 50% of the PLDLLA stand-alone cages and 83% of the PLDLLA anterior fixation cages were fused. At 12 months, 38% of the PLDLLA stand-alone and 83% of the titanium cages realized fusion. A very mild and dispersed foreign body reaction was seen in all PLDLLA specimens. E-beam sterilized PLDLLA cages degraded more rapidly in vivo as compared to both, PLDLLA cages in vitro, and ethylene oxide sterilized poly-L-lactic acid cages in vivo. Conclusions. Within the 3—6-month period, PLDLLA stand-alone cages provided insufficient mechanical stability, which manifested as cracking and deformation of the cages and lower fusion rates. This result implies that within this time, additional stabilization is required; supplemental internal fixation proved sufficient to obtain successful fusion. In all cases, only a mild host response was seen, indicating good biocompatibility.Keywords
This publication has 45 references indexed in Scilit:
- Strength retention of 70:30 poly(L‐lactide‐co‐D,L‐lactide) following real‐time agingJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005
- A biomechanical and histological evaluation of a bioresorbable lumbar interbody fusion cageBiomaterials, 2005
- Spinal-Fusion Surgery — Advances and ConcernsNew England Journal of Medicine, 2004
- Changes in Bone Architecture During Spinal Fusion: Three Years Follow-up and the Role of Cage StiffnessSpine, 2003
- Lumbar Interbody Fusion Using the Brantigan I/F Cage for Posterior Lumbar Interbody Fusion and the Variable Pedicle Screw Placement SystemSpine, 2000
- The Effects of Dynamic Compressive Loading on Biodegradable Implants of 50–50% Polylactic Acid–Polyglycolic AcidTissue Engineering, 1996
- A new saw technique improves preparation of bone sections for light and electron microscopyJournal of Applied Biomaterials, 1994
- Mechanisms of biodegradation of implantable polymersClinical Materials, 1992
- A Simple Method for Preparing Thin (10 μm) Histological Sections of Undecalcified Plastic Embedded Bone with ImplantsStain Technology, 1988
- Bone histomorphometry: Standardization of nomenclature, symbols, and units: Report of the asbmr histomorphometry nomenclature committeeJournal of Bone and Mineral Research, 1987