Comparison of Four Refractometers for the Investigation of the Passive Transfer in Beef Calves
Authors:
- 1 November 2011
- journal article
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 25 (6) , 1465-1469
Abstract
Background: Failure of passive transfer (FPT) in beef calves can be detected by refractometry. Nevertheless, different models of refractometers are available, and few studies compare them for the detection of FPT. Objectives: To compare the accuracy of 4 different refractometers for measuring serum total protein concentrations in comparison with results obtained by the biuret method and, based on the serum IgG threshold of 1,600 mg/mL, to determine, for each refractometer, the optimal serum protein concentration's lowest threshold for successful passive transfer. Animals: One hundred and eight healthy beef calves, 3–8 days of age. Methods: Observational study. The concentrations of serum total proteins were determined with 4 different models of refractometers and compared with the biuret method by a Bland–Altman statistical method. The optimal serum protein concentration's lowest threshold for successful passive transfer was determined for each refractometer by receiver operating characteristic (ROC) analysis. In addition, the serum immunoglobulin G (IgG) concentration was compared with the serum gamma-glutamyl transferase (γ-GT) activity and with the total immunoglobulin concentration. Results: The refractometric measurements were highly correlated with those obtained by the biuret method. Serum total protein concentration threshold values of 56, 58, 54, and 56 g/L were found respectively for the Atago, Atago ATC, Wolf ATC, and digital ATC refractometers. Immunoglobulins were highly correlated with IgG, whereas γ-GT only reflected colostrum uptake by the calf. Conclusions and clinical importance: All refractometers could be used for the assessment of passive transfer using their individual serum protein concentration threshold.Keywords
This publication has 12 references indexed in Scilit:
- Estimation of diagnostic-test sensitivity and specificity through Bayesian modelingPreventive Veterinary Medicine, 2005
- Comparison of refractometers and test endpoints in the measurement of serum protein concentration to assess passive transfer status in calvesJournal of the American Veterinary Medical Association, 2002
- The Usefulness and Limitations of Hand‐held Refractometers in Veterinary Laboratory Medicine: An Historical and Technical ReviewVeterinary Clinical Pathology, 2001
- Prediction of Serum IgG1 Concentration in Beef Calves Based on Age and Serum Gamma-Glutamyl-Transferase ActivityJournal of Veterinary Internal Medicine, 1999
- Model to Predict Septicemia in Diarrheic CalvesJournal of Veterinary Internal Medicine, 1999
- Prediction of Serum IgG1 Concentration in Holstein Calves Using Serum Gamma Glutamyltransferase ActivityJournal of Veterinary Internal Medicine, 1997
- Factors associated with mortality to 21 days of life in dairy heifers in the United StatesPreventive Veterinary Medicine, 1996
- Septicemic Colibacillosis and Failure of Passive Transfer of Colostral Immunoglobulin in CalvesVeterinary Clinics of North America: Food Animal Practice, 1985
- Early Variations of Blood Plasma Gamma-Glutamyl Transferase in Newborn Calves — A Test of Colostrum IntakeJournal of Dairy Science, 1982
- COMPARISON OF TOTAL SERUM PROTEIN DETERMINED BY T/S METER AND BIURET TECHNIQUE:Veterinary Clinical Pathology, 1976