Long‐term retrospective study of narrow implants for fixed dental prostheses
- 2 April 2012
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 24 (8) , 847-852
Abstract
Objective: The objectives of this study were to analyze retrospectively the long‐term survival and success rates of Narrow implants (NIs) placed with various implant systems, and the association with biological and technical complications.Material and methods: In total, 338 patients (men = 45.6%, women = 54.4%) who received 541 NIs (≤3.5 mm in diameter) for fixed prostheses were enrolled in this retrospective study. The mean marginal bone level (MMBL) change was calculated. Life table analysis with the cumulative survival rate and success rate was calculated, and biological and technical complications were evaluated.Results: The annual MMBL change was 0.07 ± 0.20 mm. The 12‐year cumulative survival (success) rates of NIs were 98.1% (91.8%) and 98.5% (93.8%) for the implant‐ and subject‐based analysis, respectively. During the observation period up to 12 years (mean 4.9 years), six implants were lost in the maxilla, whereas three implants were lost in the mandible. Technical complications were more frequent than biological complications. Infection was the most common underlying cause of biological complications and the most frequent technical complication was decementation.Conclusion: In conclusion, the findings of this study suggest that NIs could be used safely for narrow alveolar ridges or narrow mesiodistal spaces on the basis of their high survival rate.Keywords
This publication has 26 references indexed in Scilit:
- Alveolar Distraction Osteogenesis of the Severely Atrophic Anterior Maxilla: Surgical and Prosthetic ChallengesJournal of Prosthodontics, 2011
- Iliac Crest Autogenous Bone Graft versus Alloplastic Graft and Guided Bone Regeneration in the Reconstruction of Atrophic Maxillae: A 5-Year Retrospective Study on Cost-Effectiveness and Clinical OutcomeClinical Implant Dentistry and Related Research, 2010
- Evaluation of 316 narrow diameter implants followed for 5–10 years: a clinical and radiographic retrospective studyClinical Oral Implants Research, 2010
- Prospective Evaluation of Immediate and Delayed Provisional Single Tooth RestorationsJournal of Oral and Maxillofacial Surgery, 2009
- Clinical outcomes of GBR procedures to correct peri‐implant dehiscences and fenestrations: a systematic reviewClinical Oral Implants Research, 2009
- The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: A three-dimensional finite element analysisThe Journal of Prosthetic Dentistry, 2008
- Dimensional ridge alterations following tooth extraction. An experimental study in the dogJournal of Clinical Periodontology, 2005
- The use of reduced healing times on ITI® implants with a sandblasted and acid‐etched (SLA) surface:Clinical Oral Implants Research, 2002
- Basic surgical principles with ITI implants NoteClinical Oral Implants Research, 2000
- Tissue integration of non‐submerged implants. l‐year results of a prospective study with 100 ITI hollow‐cylinder and hollow‐screw implants.Clinical Oral Implants Research, 1990