Determination of Ammonium Ion Using a Reagentless Amperometric Biosensor Based on Immobilized Alanine Dehydrogenase
Open Access
- 29 September 2011
- Vol. 11 (10) , 9344-9360
Abstract
The use of the enzyme alanine dehydrogenase (AlaDH) for the determination of ammonium ion (NH4+) usually requires the addition of pyruvate substrate and reduced nicotinamide adenine dinucleotide (NADH) simultaneously to effect the reaction. This addition of reagents is inconvenient when an enzyme biosensor based on AlaDH is used. To resolve the problem, a novel reagentless amperometric biosensor using a stacked methacrylic membrane system coated onto a screen-printed carbon paste electrode (SPE) for NH4+ ion determination is described. A mixture of pyruvate and NADH was immobilized in low molecular weight poly(2-hydroxyethyl methacrylate) (pHEMA) membrane, which was then deposited over a photocured pHEMA membrane (photoHEMA) containing alanine dehydrogenase (AlaDH) enzyme. Due to the enzymatic reaction of AlaDH and the pyruvate substrate, NH4+ was consumed in the process and thus the signal from the electrocatalytic oxidation of NADH at an applied potential of +0.55 V was proportional to the NH4+ ion concentration under optimal conditions. The stacked methacrylate membranes responded rapidly and linearly to changes in NH4+ ion concentrations between 10–100 mM, with a detection limit of 0.18 mM NH4+ ion. The reproducibility of the amperometrical NH4+ biosensor yielded low relative standard deviations between 1.4–4.9%. The stacked membrane biosensor has been successfully applied to the determination of NH4+ ion in spiked river water samples without pretreatment. A good correlation was found between the analytical results for NH4+ obtained from the biosensor and the Nessler spectrophotometric method.Keywords
This publication has 30 references indexed in Scilit:
- A multi-commuted flow injection system with a multi-channel propulsion unit placed before detection: Spectrophotometric determination of ammoniumAnalytica Chimica Acta, 2007
- Potentiometric determination of activity coefficients for NH4Cl in the ternary NH4Cl/LiCl/H2O mixed electrolyte systemJournal of Electroanalytical Chemistry, 2005
- Fluorometric determination of ammonium ion by ion chromatography using postcolumn derivatization with o-phthaldialdehydeJournal of Chromatography A, 2005
- Improved detection limit for ammonium/ammonia achieved by Berthelot's reaction by use of solid-phase extraction coupled to diffuse reflectance spectroscopyAnalytica Chimica Acta, 2005
- Sequential flow injection analysis of ammonium and nitrate using gas phase molecular absorption spectrometryTalanta, 2004
- Determination of inorganic cations and ammonium in environmental waters by ion chromatography with a high-capacity cation-exchange columnJournal of Chromatography A, 2002
- A flow injection-fluorometric method for the determination of ammonium in fresh and saline waters with a view to in situ analysesWater Research, 2001
- Novel solid-state ammonium ion potentiometric sensor based on zirconium titanium phosphate ion exchangerAnalytica Chimica Acta, 2001
- Fluorometric determination of ammonia in sea and estuarine waters by direct segmented flow analysisMarine Chemistry, 1997
- On-line flow injection monitoring of ammonia in industrial liquid effluentsAnalytica Chimica Acta, 1995