Abstract
Biomechanical and clinical studies have shown that syndesmosis screws may be indicated in repairing Weber C ankle fractures. This study sought to determine the effect of the number of cortices of screw purchase and ankle position on syndesmosis width and tibiotalar rotation in Weber C ankle fracture fixation. Nine pairs of human cadaver legs were mechanically tested to determine syndesmosis width and tibiotalar rotation. This was done for intact specimens and after a Weber C injury was created and repaired with 3 and 4 cortices of purchase. Tests were performed for no axial load and for axial loads of 700 N with and without external torques of 1 and 5 Nm on the ankle. Torque-to-failure tests were also done for 4 cortices of fixation. In comparison to baseline, the syndesmosis width was significantly decreased when the syndesmosis screw was inserted in plantarflexion with either 0 or 1 Nm of torque. Syndesmosis width significantly increased when the screw was inserted in dorsiflexion for 5 Nm of torque. For tibiotalar rotation, no statistical differences were detected for either plantarflexion or dorsiflexion when compared to baseline, except with axial load. Syndesmosis width was not affected by the number of cortices purchased by the syndesmosis screw. Failure torque and failure angle were also measured. Because no difference was seen between 3 or 4 cortices, it is the surgeon's choice in determining how many cortices of fixation are achieved.Keywords
This publication has 16 references indexed in Scilit:
- Tricortical Versus Quadricortical Syndesmosis Fixation in Ankle FracturesJournal of Orthopaedic Trauma, 2004
- Overtightening of the Ankle Syndesmosis: Is It Really Possible?Journal of Bone and Joint Surgery, 2001
- Biomechanical Comparison of Syndesmosis Fixation with 3.5- and 4.5-millimeter Stainless Steel ScrewsFoot & Ankle International, 2000
- Comparison of Tricortical Screw Fixation Versus a Modified Suture Construct for Fixation of Ankle Syndesmosis Injury: A Biomechanical StudyJournal of Orthopaedic Trauma, 1999
- Syndesmotic Screw Placement: A Biomechanical AnalysisFoot & Ankle International, 1997
- An Axially Loaded Model of the Ankle After Pronation External Rotation InjuryClinical Orthopaedics and Related Research, 1996
- The tibiofibular syndesmosis. Evaluation of the ligamentous structures, methods of fixation, and radiographic assessment.Journal of Bone and Joint Surgery, 1995
- Operative Treatment of Syndesmotic Disruptions Without Use of a Syndesmotic Screw: A Prospective Clinical StudyFoot & Ankle International, 1994
- Tibiotalar Joint Dynamics: Indications for the Syndesmotic Screw—A Cadaver StudyFoot & Ankle, 1993
- The effect of the syndesmotic screw on the extension capacity of the ankle jointArchives of orthopaedic and trauma surgery, 1985