Deep‐learning synthesized pseudo‐CT for MR high‐resolution pediatric cranial bone imaging (MR‐HiPCB)
- 17 June 2022
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (5) , 2285-2297
Abstract
Purpose: CT is routinely used to detect cranial abnormalities in pediatric patients with head trauma or craniosynostosis. This study aimed to develop a deep learning method to synthesize pseudo‐CT (pCT) images for MR high‐resolution pediatric cranial bone imaging to eliminating ionizing radiation from CT.Methods: 3D golden‐angle stack‐of‐stars MRI were obtained from 44 pediatric participants. Two patch‐based residual UNets were trained using paired MR and CT patches randomly selected from the whole head (NetWH) or in the vicinity of bone, fractures/sutures, or air (NetBA) to synthesize pCT. A third residual UNet was trained to generate a binary brain mask using only MRI. The pCT images from NetWH (pCTNetWH) in the brain area and NetBA (pCTNetBA) in the nonbrain area were combined to generate pCTCom. A manual processing method using inverted MR images was also employed for comparison.Results: pCTCom (68.01 ± 14.83 HU) had significantly smaller mean absolute errors (MAEs) than pCTNetWH (82.58 ± 16.98 HU, P < 0.0001) and pCTNetBA (91.32 ± 17.2 HU, P < 0.0001) in the whole head. Within cranial bone, the MAE of pCTCom (227.92 ± 46.88 HU) was significantly lower than pCTNetWH (287.85 ± 59.46 HU, P < 0.0001) but similar to pCTNetBA (230.20 ± 46.17 HU). Dice similarity coefficient of the segmented bone was significantly higher in pCTCom (0.90 ± 0.02) than in pCTNetWH (0.86 ± 0.04, P < 0.0001), pCTNetBA (0.88 ± 0.03, P < 0.0001), and inverted MR (0.71 ± 0.09, P < 0.0001). Dice similarity coefficient from pCTCom demonstrated significantly reduced age dependence than inverted MRI. Furthermore, pCTCom provided excellent suture and fracture visibility comparable to CT.Conclusion: MR high‐resolution pediatric cranial bone imaging may facilitate the clinical translation of a radiation‐free MR cranial bone imaging method for pediatric patients.Keywords
Funding Information
- National Center for Advancing Translational Sciences (UL1TR002345)
- National Institute of Biomedical Imaging and Bioengineering
- National Institutes of Health
- National Center for Advancing Translational Sciences
- Institute of Clinical and Translational Sciences
This publication has 54 references indexed in Scilit:
- Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT imagesMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort studyThe Lancet, 2012
- “Black bone” MRI: a partial flip angle technique for radiation reduction in craniofacial imagingBritish Journal of Radiology, 2012
- Normal Sagittal and Coronal Suture Widths by Using CT ImagingAmerican Journal of Neuroradiology, 2011
- Use of Medical Imaging Procedures With Ionizing Radiation in ChildrenArchives of Pediatrics & Adolescent Medicine, 2011
- Intracranial Volumes in a Large Series of Healthy ChildrenPlastic and Reconstructive Surgery, 2009
- MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas RegistrationJournal of Nuclear Medicine, 2008
- COMPUTED TOMOGRAPHY SCANNING IN CHILDREN: Radiation RisksPediatric Hematology and Oncology, 2001
- A population-based study of craniosynostosisJournal of Clinical Epidemiology, 1990
- Reducing motion artifacts in two-dimensional Fourier transform imagingMagnetic Resonance Imaging, 1986