Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints
Authors:
- J. FisherJFJ. Fisher
- D. DowsonDDD. Dowson
- C. HardakerCHC. Hardaker
- K. BrummittKBK. Brummitt
- 1 May 1994
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 16 (3) , 229-236
Abstract
The wear of ultra high molecular weight polyethylene (UHMWPE) when sliding against zirconia ceramic and stainless steel counterfaces has been compared in a pin-on-plate reciprocator and in a hip joint simulator. A lower wear factor was found for the UHMWPE when sliding on the zirconia ceramic counterfaces in the pin-on-plate tests. In the hip joint simulator test, the acetabular cups articulating on zirconia heads showed consistently lower volume changes than the cups articulating on stainless steel heads. The higher volume changes found with the stainless steel heads were associated with an increased roughness of the femoral heads during the tests. This roughening was caused by the adherence of a rough polymer transfer film.Keywords
This publication has 15 references indexed in Scilit:
- Observations of residual sub-surface shear strain in the ultrahigh molecular weight polyethylene acetabular cups of hip prosthesesJournal of Materials Science: Materials in Medicine, 1994
- An evaluation of the penetration of ceramic femoral heads into polyethylene acetabular cupsWear, 1993
- Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethyleneWear, 1993
- The effect of transfer film and surface roughness on the wear of lubricated ultra-high molecular weight polyethyleneClinical Materials, 1993
- Wear of the polyethylene acetabular cup: Metallic and ceramic heads compared in a hip simulatorActa Orthopaedica, 1993
- Low wear rate of UHMWPE against zirconia ceramic (Y‐PSZ) in comparison to alumina ceramic and SUS 316L alloyJournal of Biomedical Materials Research, 1991
- Ceramic bearing surfaces in total artificial joints: Resistance to third body wear damage from bone cement particlesJournal of Medical Engineering & Technology, 1991
- The role of counterface imperfections in the wear of polyethyleneWear, 1987
- The Role of Cement in the Long Term Performance and Premature Failure of Charnley Low Friction ArthroplastiesEngineering in Medicine, 1986
- The effect of the surface finish of alumina and stainless steel on the wear rate of UHMW polyethyleneBiomaterials, 1986