Matrix Effect Elimination During LC–MS/MS Bioanalytical Method Development
Authors:
- 21 October 2009
- journal article
- research article
- Published by Taylor & Francis in Bioanalysis
- Vol. 1 (7) , 1243-1257
Abstract
Due to the presence of endogenous components in biofluids, ionization suppression or enhancement may occur for bioanalytical assays using LC-MS or LC-MS/MS technologies. The matrix effect may affect the precision and accuracy of a bioanalytical method and, therefore, compromise the quality of the results. Protein precipitation sample preparation along with LC-MS/MS is a high-throughput method most commonly used in bioanalysis and is largely affected by the matrix effect. In order to eliminate the matrix effect during the method development, some considerations may be used: cleaner sample preparations, more sensitive instruments, which allow less material to be injected, different chromatographic separations and much more must be investigated. More than giving tools to adequately assess the matrix effect during the method development, this review gives scientists numerous ways to eliminate or reduce the matrix effect based on novel sample-preparation techniques, new chromatographic optimization methods and new technologies.Keywords
This publication has 51 references indexed in Scilit:
- A novel strategy for reducing phospholipids-based matrix effect in LC–ESI-MS bioanalysis by means of HybridSPEJournal of Pharmaceutical and Biomedical Analysis, 2009
- State-of-the-art in atmospheric pressure photoionization for LC/MSAnalytica Chimica Acta, 2008
- Recent advances in high-throughput quantitative bioanalysis by LC–MS/MSJournal of Pharmaceutical and Biomedical Analysis, 2007
- Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analysesJournal of Chromatography B, 2007
- Comparison of Atmospheric Pressure Photoionization and Atmospheric Pressure Chemical Ionization for Normal-Phase LC/MS Chiral Analysis of PharmaceuticalsAnalytical Chemistry, 2007
- Does a stable isotopically labeled internal standard always correct analyte response?Journal of Pharmaceutical and Biomedical Analysis, 2007
- A study of matrix effects on an LC/MS/MS assay for olanzapine and desmethyl olanzapineJournal of Pharmaceutical and Biomedical Analysis, 2004
- Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standardRapid Communications in Mass Spectrometry, 2003
- Investigations of the electrospray interface for liquid chromatography/mass spectrometryAnalytical Chemistry, 1990
- Ion spray interface for combined liquid chromatography/atmospheric pressure ionization mass spectrometryAnalytical Chemistry, 1987