Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio
Top Cited Papers
- 22 September 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 63 (5) , 964-972
Abstract
Pulse transit time (PTT) has attracted much interest for cuffless blood pressure (BP) measurement. However, its limited accuracy is one of the main problems preventing its widespread acceptance. Arterial BP oscillates mainly at high frequency (HF) because of respiratory activity, and at low frequency (LF) because of vasomotor tone. Prior studies suggested that PTT can track BP variation in HF range, but was inadequate to follow the LF variation, which is probably the main reason for its unsatisfactory accuracy. This paper presents a new indicator, the photoplethysmogram intensity ratio (PIR), which can be affected by changes in the arterial diameter, and, thus, trace the LF variation of BP. Spectral analysis of BP, PTT, PIR, and respiratory signal confirmed that PTT was related to BP in HF at the respiratory frequency, while PIR was associated with BP in LF range. We, therefore, develop a novel BP estimation algorithm by using both PTT and PIR. The proposed algorithm was validated on 27 healthy subjects with continuous Finapres BP as reference. The results showed that the mean ± standard deviation (SD) for the estimated systolic, diastolic, and mean BP with the proposed method against reference were -0.37 ± 5.21, -0.08 ± 4.06, -0.18 ± 4.13 mmHg, and mean absolute difference (MAD) were 4.09, 3.18, 3.18 mmHg, respectively. Furthermore, the proposed method outperformed the two most cited PTT algorithms for about 2 mmHg in SD and MAD. These results demonstrated that the proposed BP model using PIR and PTT can estimate continuous BP with improved accuracy.Keywords
Funding Information
- Guangdong Innovation Research Team Fund for Low-cost Healthcare Technologies in China
- Chinese Academy of Sciences (GJHZ1212)
This publication has 44 references indexed in Scilit:
- Assessment and management of blood-pressure variabilityNature Reviews Cardiology, 2013
- Short- and Long-Term Blood Pressure VariabilityHypertension, 2012
- Time–frequency analysis of variabilities of heart rate, systolic blood pressure and pulse transit time before and after exercise using the recursive autoregressive modelBiomedical Signal Processing and Control, 2011
- Continuous and Noninvasive Blood Pressure Measurement: A Novel Modeling Methodology of the Relationship Between Blood Pressure and Pulse Wave VelocityAnnals of Biomedical Engineering, 2009
- Spectral Analysis of Blood Pressure and Heart Rate Variability in Evaluating Cardiovascular RegulationHypertension, 1995
- Physiology and clinical implications of variability of cardiovascular parameters with focus on heart rate and blood pressureThe American Journal of Cardiology, 1994
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Measurements of Young's modulus of elasticity of the canine aorta with ultrasoundUltrasonic Imaging, 1979
- Regulation of Blood VesselsCirculation, 1960
- Respiratory Variations in Blood PressureCirculation, 1952