The accuracy of implantation is an accepted prognostic factor for the long‐term survival of unicompartmental knee prostheses (UKP). We developed a non‐image‐guided navigation system for UKP implantation without any extramedullary or intramedullary guiding device. The 30 patients operated on with the navigation system (group A) were matched to 30 patients operated on with the conventional technique (group B) using age, sex, body mass index, preoperative coronal mechanical femorotibial angle, and severity of the preoperative degenerative changes. All patients had a complete radiological examination in the first 3 months after the index procedure, with anteroposterior and lateral plain knee radiographs and anteroposterior and lateral long leg radiographs. Coronal femorotibial mechanical angle and both coronal and sagittal orientations of the femoral and tibial components were measured. There were no significant differences in the mean numerical values of all measured angles except for the sagittal orientation of the tibial component, with a significant excessive posterior tibial slope in group B. There was a significant increase in the rate of prostheses implanted in the desired angular range for all criteria except the coronal mechanical femorotibial angle in group A. An optimal implantation with all optimal items was obtained by 18 cases in group A and 6 cases in group B. Navigated implantation of a UKP with the used, non‐image‐based system improved the accuracy of the radiological implantation without any significant inconvenience and with little change in the conventional operative technique. The only inconvenience was a 20‐min longer operative time. This improvement could be related to a longer survival of such implanted prostheses.Keywords
This publication has 19 references indexed in Scilit:
- [Computer-assisted implantation of a total knee arthroplasty: a case-controlled study in comparison with classical instrumentation].2001
- Patient satisfaction after knee arthroplasty: A report on 27,372 knees operated on between 1981 and 1995 in SwedenActa Orthopaedica, 2000
- Unicompartmental Knee ReplacementClinical Orthopaedics and Related Research, 1999
- Computer Assisted Knee ReplacementClinical Orthopaedics and Related Research, 1998
- Unicompartmental or total knee replacement?The Journal of Bone and Joint Surgery. British volume, 1998
- Unicompartmental arthroplastyThe Journal of Arthroplasty, 1998
- Unicompartmental knee arthroplasty in middle-aged patientsThe Journal of Arthroplasty, 1998
- Unicompartmental knee arthroplasty surgeryThe Journal of Arthroplasty, 1996
- Miller—Galante unicompartmental knee arthroplasty at 2- to 5-year follow-up evaluationsThe Journal of Arthroplasty, 1995
- Early failure of the femoral component in unicompartmental knee arthroplastyThe Journal of Arthroplasty, 1995