Urban Eriksson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Urban Eriksson has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Albert Alm
Department of Ophthalmology, University Hospital, Uppsala, Sweden
2 shared publicationsA Alm
1 shared publicationEva Larsson
Department of Ophthalmology, University Hospital, Uppsala, Sweden
1 shared publication
Latest Publications
- Open Access
- 4 March 2011
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (7) , 620-627
Is quantitative spectral‐domain superior to time‐domain optical coherence tomography (OCT) in eyes with age‐related macular degeneration?
: Purpose: The aim of this study was to determine the variability of macular map measurements, for two generations of optical coherence tomography (OCT) instruments, in eyes with wet age related macular degeneration (AMD) and low visual acuity.Methods: Patients were examined with Stratus OCT and Cirrus HD‐OCT. The macular thickness was assessed with the ‘macular thickness map scan’ and ‘fast protocol’ in Stratus and with the 512 × 128 and 200 × 200 cube protocols in Cirrus OCT. Two measurements were taken one directly after the other, at the first visit to analyse repeatability. Approximately 1 week later, a third measurement was taken to analyse reproducibility. In Cirrus OCT, a manual correction of foveal location was also performed. Repeatability and reproducibility were calculated as a coefficient of variance (CoV) and a coefficient of repeatability/reproducibility.Results: Repeatability for central macular thickness (expressed as CoV) was about three per cent for all protocols, and the coefficient of repeatability between 34 and 54 μm. Reproducibility (also expressed as CoV) was between four to seven per cent and coefficient of repeatability between 64 and 89 μm. After manual adjustment of foveal location in Cirrus OCT, the coefficient of repeatability improved to 12–18 μm, and the coefficient of reproducibility to 44–47 μm.Conclusions: In eyes affected by wet AMD, there were small differences in repeatability and reproducibility when comparing quantitative maps in Stratus and Cirrus OCT. However, when the software for manual correction of foveal position in Cirrus OCT was used, the variability decreased markedly, and the repeatability was close to what had been reported in normal eyes, demonstrating a significant, potential advantage of spectral‐domain over time‐domain OCT.
- 4 March 2011
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (7) , 620-627
Open AccessIs quantitative spectral‐domain superior to time‐domain optical coherence tomography (OCT) in eyes with age‐related macular degeneration?
: Purpose: The aim of this study was to determine the variability of macular map measurements, for two generations of optical coherence tomography (OCT) instruments, in eyes with wet age related macular degeneration (AMD) and low visual acuity.Methods: Patients were examined with Stratus OCT and Cirrus HD‐OCT. The macular thickness was assessed with the ‘macular thickness map scan’ and ‘fast protocol’ in Stratus and with the 512 × 128 and 200 × 200 cube protocols in Cirrus OCT. Two measurements were taken one directly after the other, at the first visit to analyse repeatability. Approximately 1 week later, a third measurement was taken to analyse reproducibility. In Cirrus OCT, a manual correction of foveal location was also performed. Repeatability and reproducibility were calculated as a coefficient of variance (CoV) and a coefficient of repeatability/reproducibility.Results: Repeatability for central macular thickness (expressed as CoV) was about three per cent for all protocols, and the coefficient of repeatability between 34 and 54 μm. Reproducibility (also expressed as CoV) was between four to seven per cent and coefficient of repeatability between 64 and 89 μm. After manual adjustment of foveal location in Cirrus OCT, the coefficient of repeatability improved to 12–18 μm, and the coefficient of reproducibility to 44–47 μm.Conclusions: In eyes affected by wet AMD, there were small differences in repeatability and reproducibility when comparing quantitative maps in Stratus and Cirrus OCT. However, when the software for manual correction of foveal position in Cirrus OCT was used, the variability decreased markedly, and the repeatability was close to what had been reported in normal eyes, demonstrating a significant, potential advantage of spectral‐domain over time‐domain OCT.
- Open Access
- 20 October 2009
- Published by Wiley in Acta Ophthalmologica
- Vol. 87 (7) , 725-730
Repeatability in and interchangeability between the macular and the fast macular thickness map protocols: a study on normal eyes with Stratus optical coherence tomography
: Purpose: To collect a normal material and to compare the macular and the fast macular thickness map protocols regarding normal values and repeatability.Methods: Sixty‐seven individuals underwent three repeated scans with the macular thickness protocol; 45 of them also had three scans with the fast thickness protocol in Stratus optical coherence tomography (OCT). The maps were divided into nine ETDRS fields, where thickness values were presented. The repeatability was calculated as intraclass correlation coefficient (ICC), coefficient of variance (CV) and coefficient of repeatability (CR). For comparison between the two protocols, limits of agreement were determined according to Bland–Altman.Results: Normal values for the two protocols were very close. Repeatability was high. ICC for all areas was 0.92–0.98. CV was less than 1% and CR was 6–8 μm for both protocols, with the exception of the fovea in the fast protocol (where CV was 1.44% and CR 12.4 μm). Limits of agreement between the two protocols were less than 10 μm as a rule.Conclusion: Normal values for the protocols are equal and they both have excellent repeatability. The fast macular map is a good alternative with the possible exception of the fovea, where variation is twice that of the macular thickness map.
- 20 October 2009
- Published by Wiley in Acta Ophthalmologica
- Vol. 87 (7) , 725-730
Open AccessRepeatability in and interchangeability between the macular and the fast macular thickness map protocols: a study on normal eyes with Stratus optical coherence tomography
: Purpose: To collect a normal material and to compare the macular and the fast macular thickness map protocols regarding normal values and repeatability.Methods: Sixty‐seven individuals underwent three repeated scans with the macular thickness protocol; 45 of them also had three scans with the fast thickness protocol in Stratus optical coherence tomography (OCT). The maps were divided into nine ETDRS fields, where thickness values were presented. The repeatability was calculated as intraclass correlation coefficient (ICC), coefficient of variance (CV) and coefficient of repeatability (CR). For comparison between the two protocols, limits of agreement were determined according to Bland–Altman.Results: Normal values for the two protocols were very close. Repeatability was high. ICC for all areas was 0.92–0.98. CV was less than 1% and CR was 6–8 μm for both protocols, with the exception of the fovea in the fast protocol (where CV was 1.44% and CR 12.4 μm). Limits of agreement between the two protocols were less than 10 μm as a rule.Conclusion: Normal values for the protocols are equal and they both have excellent repeatability. The fast macular map is a good alternative with the possible exception of the fovea, where variation is twice that of the macular thickness map.
- 1 November 2008
- Published by BMJ in British Journal of Ophthalmology
- Vol. 93 (11) , 1448-1452
Macular thickness decreases with age in normal eyes: a study on the macular thickness map protocol in the Stratus OCT
Background/aim: Retinal and retinal nerve fibre layer (RNFL) thinning with age have been described in histological studies. In vivo techniques like optical coherence tomography (OCT) have shown thinning of optic nerve RNFL and the retina in specific areas. One would expect thinning of the total macula, but so far, no correlation with the quantitative OCT macular map tool and age has been found. Methods: Sixty-seven healthy individuals underwent three repeated scans in both eyes with the macular thickness map protocol in the Stratus OCT. That protocol divides the macula area into nine ETDRS fields. The RNFL was measured in one specific location close to the optic disc. Correlations between retinal, RNFL thickness, macular volume and age were determined. Results: We found a statistically significant negative relationship between retinal thickness and age for all ETDRS areas, total macular volume and RNFL thickness. Retinal thickness decreased by 0.26–0.46 μm, macula volume 0.01 mm3 and RNFL 0.09 μm per year. Conclusion: Retinal thickness within the area covered by the macular map significantly decreases with age. In the area examined in the papillomacular bundle, 20% of the retinal thinning is due to the RNFL, and 80% is due to thinning of other layers of the retina.
- 1 November 2008
- Published by BMJ in British Journal of Ophthalmology
- Vol. 93 (11) , 1448-1452
Macular thickness decreases with age in normal eyes: a study on the macular thickness map protocol in the Stratus OCT
Background/aim: Retinal and retinal nerve fibre layer (RNFL) thinning with age have been described in histological studies. In vivo techniques like optical coherence tomography (OCT) have shown thinning of optic nerve RNFL and the retina in specific areas. One would expect thinning of the total macula, but so far, no correlation with the quantitative OCT macular map tool and age has been found. Methods: Sixty-seven healthy individuals underwent three repeated scans in both eyes with the macular thickness map protocol in the Stratus OCT. That protocol divides the macula area into nine ETDRS fields. The RNFL was measured in one specific location close to the optic disc. Correlations between retinal, RNFL thickness, macular volume and age were determined. Results: We found a statistically significant negative relationship between retinal thickness and age for all ETDRS areas, total macular volume and RNFL thickness. Retinal thickness decreased by 0.26–0.46 μm, macula volume 0.01 mm3 and RNFL 0.09 μm per year. Conclusion: Retinal thickness within the area covered by the macular map significantly decreases with age. In the area examined in the papillomacular bundle, 20% of the retinal thinning is due to the RNFL, and 80% is due to thinning of other layers of the retina.