K. Passler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
K. Passler has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Guenther Paltauf
Department of Physics, University of Graz, Universitaetsplatz 5, 8010 Graz, Austria
3 shared publications - Peter Burgholzer
Research Center for Non-Destructive Testing GmbH, Linz, Austria
3 shared publications - Robert Nuster
Department of Physics, University of Graz, Universitaetsplatz 5, Graz, 8010, Austria
3 shared publications S. Gratt
Department of physics, Karl-Franzens-Universitaet Graz, Graz, Austria
3 shared publications- Thomas Berer
Research Center for Non-Destructive Testing GmbH, Altenberger Strasse 69, 4040 Linz, Austria
1 shared publication
Latest Publications
- Open Access
- 22 August 2011
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 2 (9) , 2655-2664
Piezoelectric annular array for large depth of field photoacoustic imaging
A piezoelectric detection system consisting of an annular array is investigated for large depth of field photoacoustic imaging. In comparison to a single ring detection system, X-shaped imaging artifacts are suppressed. Sensitivity and image resolution studies are performed in simulations and in experiments and compared to a simulated spherical detector. In experiment an eight ring detection systems offers an extended depth of field over a range of 16 mm with almost constant lateral resolution.
- 22 August 2011
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 2 (9) , 2655-2664
Open AccessPiezoelectric annular array for large depth of field photoacoustic imaging
A piezoelectric detection system consisting of an annular array is investigated for large depth of field photoacoustic imaging. In comparison to a single ring detection system, X-shaped imaging artifacts are suppressed. Sensitivity and image resolution studies are performed in simulations and in experiments and compared to a simulated spherical detector. In experiment an eight ring detection systems offers an extended depth of field over a range of 16 mm with almost constant lateral resolution.
- Open Access
- 27 July 2010
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 1 (1) , 318-323
Scanning acoustic-photoacoustic microscopy using axicon transducers
A dual mode scanning acoustic microscope is investigated, yielding simultaneously images with optical and acoustical contrast. Short laser pulses are used to excite acoustic waves in a sample for the photoacoustic imaging mode. At the same time the pulses irradiate a conical target generating limited diffraction acoustic waves (X-waves) for large depth of field ultrasound imaging. For photoacoustic as well as for ultrasound imaging a focusing, ring shaped detector is applied. First phantom experiments demonstrate the possibility to acquire data for both imaging modes in a single scan, by separating images due to their different time of flight.
- 27 July 2010
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 1 (1) , 318-323
Open AccessScanning acoustic-photoacoustic microscopy using axicon transducers
A dual mode scanning acoustic microscope is investigated, yielding simultaneously images with optical and acoustical contrast. Short laser pulses are used to excite acoustic waves in a sample for the photoacoustic imaging mode. At the same time the pulses irradiate a conical target generating limited diffraction acoustic waves (X-waves) for large depth of field ultrasound imaging. For photoacoustic as well as for ultrasound imaging a focusing, ring shaped detector is applied. First phantom experiments demonstrate the possibility to acquire data for both imaging modes in a single scan, by separating images due to their different time of flight.
- 9 February 2009
- Published by AIP Publishing in Applied Physics Letters
- Vol. 94 (6) , 064108
Laser-generation of ultrasonic X-waves using axicon transducers
Photoacoustic and classical ultrasound imaging are both based upon ultrasonic waves but use different contrast mechanisms. For the development of a scanning acoustic microscope that uses both contrasts, an axicon transducer generating nondiffracting ultrasound, also called X-waves, by illumination with short laser pulses is investigated. Such a transducer provides simultaneously high depth of field and high lateral resolution. In this work, the spatial and temporal characteristics of the laser-generated X-waves are investigated using experiments and theoretical simulations. The experimental results reveal a characteristic spatial pulse width of 50 μm and a focal depth that complies well with the theoretical predictions.
- 9 February 2009
- Published by AIP Publishing in Applied Physics Letters
- Vol. 94 (6) , 064108
Laser-generation of ultrasonic X-waves using axicon transducers
Photoacoustic and classical ultrasound imaging are both based upon ultrasonic waves but use different contrast mechanisms. For the development of a scanning acoustic microscope that uses both contrasts, an axicon transducer generating nondiffracting ultrasound, also called X-waves, by illumination with short laser pulses is investigated. Such a transducer provides simultaneously high depth of field and high lateral resolution. In this work, the spatial and temporal characteristics of the laser-generated X-waves are investigated using experiments and theoretical simulations. The experimental results reveal a characteristic spatial pulse width of 50 μm and a focal depth that complies well with the theoretical predictions.