Hans Van Remoortel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hans Van Remoortel has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Thierry Troosters
Affiliations: KU Leuven-University of Leuven, Department of Rehabilitation Sciences, B-3000 Leuven, Belgium, University Hospitals Leuven, Department of Respiratory Diseases, B-3000 Leuven, Belgium
4 shared publications - Chris Burtin
Department of Rehabilitation Sciences, Katholieke Universiteit Leuven, Leuven, Belgium
3 shared publications - Daniel Langer
Research Group for Rehabilitation in Internal Disorders, Department of Rehabilitation Sciences, KU Leuven, Leuven, Belgium
3 shared publications - Marc Decramer
Respiratory Rehabilitation and Respiratory Division, University Hospital Gasthuisberg, Leuven, Belgium
2 shared publications - Rik Gosselink
R. Gosselink, PT, PhD, Rehabilitation Sciences, KU Leuven, Tervuursevest 101, 3001 Leuven, Belgium
2 shared publications - An Lehouck
Respiratory Division and Rehabilitation, Laboratory of Pneumology, University Hospital Gasthuisberg, KULeuven, Herestraat 49, Leuven, 3000, Belgium
1 shared publication
Latest Publications
- Open Access
- 25 May 2013
- Published by Springer Nature in Respiratory Research
- Vol. 14 (1) , 1-8
The minimal important difference of the pulmonary functional status and dyspnea questionnaire in patients with severe chronic obstructive pulmonary disease
Background: The modified version of the Pulmonary Functional Status and Dyspnea Questionnaire (PFSDQ-M) is used in patients with COPD to obtain information about their functional status. It consists of 3 components (change in activities, dyspnea and fatigue) ranging from 0 to 100 and has been shown to be responsive following pulmonary rehabilitation (PR). The interpretation of changes in PFSDQ-M score after an intervention is difficult in the absence of the minimal important difference (MID) of the PFSDQ-M. This study aims at investigating the MID of the PFSDQ-M. Methods: We enrolled 301 patients with COPD (FEV1 42 ± 15%pred) that completed the PFSDQ-M before and after a 3-month PR program (∆Chronic Respiratory Disease Questionnaire (CRDQ) +16 ± 12 points, ∆Six-minute walking distance (6MWD) +47 ± 89 m, both p < 0.001). An anchor-based approach consisted of calculating the correlation between the ∆PFSDQ-M and anchors with an established MID (∆CRDQ and ∆6MWD). Linear regression analyses were performed to predict the MID from these anchors. Secondly several distribution-based approaches (Cohen’s effect size, empirical rule effect size and standard error of measurement method) were used. Results: Anchor-based estimates for the different PFSDQ-M-components were between −3 and −5 points based on CRDQ score and −6 (only calculated for change in activities) based on 6MWD. Using the distribution-based methods, the estimates of MID ranged from −3 to −5 points for the different components. Conclusions: We concluded that the estimate of MID of the PFSDQ-M after pulmonary rehabilitation corresponds to a change of 5 points (range - 3 to −6) in each component in patients with severe COPD.
- 25 May 2013
- Published by Springer Nature in Respiratory Research
- Vol. 14 (1) , 1-8
Open AccessThe minimal important difference of the pulmonary functional status and dyspnea questionnaire in patients with severe chronic obstructive pulmonary disease
Background: The modified version of the Pulmonary Functional Status and Dyspnea Questionnaire (PFSDQ-M) is used in patients with COPD to obtain information about their functional status. It consists of 3 components (change in activities, dyspnea and fatigue) ranging from 0 to 100 and has been shown to be responsive following pulmonary rehabilitation (PR). The interpretation of changes in PFSDQ-M score after an intervention is difficult in the absence of the minimal important difference (MID) of the PFSDQ-M. This study aims at investigating the MID of the PFSDQ-M. Methods: We enrolled 301 patients with COPD (FEV1 42 ± 15%pred) that completed the PFSDQ-M before and after a 3-month PR program (∆Chronic Respiratory Disease Questionnaire (CRDQ) +16 ± 12 points, ∆Six-minute walking distance (6MWD) +47 ± 89 m, both p < 0.001). An anchor-based approach consisted of calculating the correlation between the ∆PFSDQ-M and anchors with an established MID (∆CRDQ and ∆6MWD). Linear regression analyses were performed to predict the MID from these anchors. Secondly several distribution-based approaches (Cohen’s effect size, empirical rule effect size and standard error of measurement method) were used. Results: Anchor-based estimates for the different PFSDQ-M-components were between −3 and −5 points based on CRDQ score and −6 (only calculated for change in activities) based on 6MWD. Using the distribution-based methods, the estimates of MID ranged from −3 to −5 points for the different components. Conclusions: We concluded that the estimate of MID of the PFSDQ-M after pulmonary rehabilitation corresponds to a change of 5 points (range - 3 to −6) in each component in patients with severe COPD.
- Open Access
- 19 April 2013
- Published by Springer Nature in Respiratory Research
- Vol. 14 (1) , 1-8
Impact of exacerbations of cystic fibrosis on muscle strength
Adult patients with cystic fibrosis have peripheral muscle weakness, which is related to exercise intolerance and poor prognosis. The influence of acute exacerbations on muscle strength has been poorly studied. This study aimed to investigate whether quadriceps force (QF), as assessed with an involuntary technique, changes during intravenous antibiotics therapy (IVAT) for an exacerbation. QF was measured in 20 patients using twitch stimulation of the femoral nerve at the day of hospitalization (day 1) and at termination (day 14) of the IVAT. Physical activity was monitored during IVAT using a SenseWear armband. Ten stable patients served as control subjects. QF did not change during exacerbation (potentiated twitch force at day 1: 140 ± 42 N, at day 14: 140 ± 47 N), but a decrease was observed in individual patients. Changes in twitch force during exacerbation were correlated with time spent in activities of at least moderate intensity (r = 0.61, p = 0.007). QF does not systematically decrease during exacerbations of cystic fibrosis. Individual changes in QF are well correlated with daily time spent in activities of at least moderate intensity.
- 19 April 2013
- Published by Springer Nature in Respiratory Research
- Vol. 14 (1) , 1-8
Open AccessImpact of exacerbations of cystic fibrosis on muscle strength
Adult patients with cystic fibrosis have peripheral muscle weakness, which is related to exercise intolerance and poor prognosis. The influence of acute exacerbations on muscle strength has been poorly studied. This study aimed to investigate whether quadriceps force (QF), as assessed with an involuntary technique, changes during intravenous antibiotics therapy (IVAT) for an exacerbation. QF was measured in 20 patients using twitch stimulation of the femoral nerve at the day of hospitalization (day 1) and at termination (day 14) of the IVAT. Physical activity was monitored during IVAT using a SenseWear armband. Ten stable patients served as control subjects. QF did not change during exacerbation (potentiated twitch force at day 1: 140 ± 42 N, at day 14: 140 ± 47 N), but a decrease was observed in individual patients. Changes in twitch force during exacerbation were correlated with time spent in activities of at least moderate intensity (r = 0.61, p = 0.007). QF does not systematically decrease during exacerbations of cystic fibrosis. Individual changes in QF are well correlated with daily time spent in activities of at least moderate intensity.
- Open Access
- 25 September 2012
- Published by Springer Nature in Respiratory Research
- Vol. 13 (1) , 84
Vitamin D supplementation during rehabilitation in COPD: a secondary analysis of a randomized trial
Rationale: Pulmonary rehabilitation is an important treatment for patients with Chronic Obstructive Pulmonary Disease, who are often vitamin D deficient. As vitamin D status is linked to skeletal muscle function, we aimed to explore if high dose vitamin D supplementation can improve the outcomes of rehabilitation in Chronic Obstructive Pulmonary Disease. Material and methods: This study is a post-hoc subgroup analysis of a larger randomized trial comparing a monthly dose of 100.000 IU of vitamin D with placebo to reduce exacerbations. 50 Subjects who followed a rehabilitation program during the trial are included in this analysis. We report changes from baseline in muscle strength and exercise performance between both study arms after 3 months of rehabilitation. Results: Vitamin D intervention resulted in significantly higher median vitamin D levels compared to placebo (51 [44-62] ng/ml vs 15 [13-30] ng/ml; p < 0.001). Patients receiving vitamin D had significantly larger improvements in inspiratory muscle strength (-11±12 cmH2O vs 0±14 cmH2O; p = 0.004) and maximal oxygen uptake (110±211 ml/min vs -20±187 ml/min; p = 0.029). Improvements in quadriceps strength (15±16 Nm) or six minutes walking distance (40±55 meter) were not significantly different from the effects in the placebo group (7±19 Nm and 11±74 meter; p>0.050). Conclusion: High dose vitamin D supplementation during rehabilitation may have mild additional benefits to training.
- 25 September 2012
- Published by Springer Nature in Respiratory Research
- Vol. 13 (1) , 84
Open AccessVitamin D supplementation during rehabilitation in COPD: a secondary analysis of a randomized trial
Rationale: Pulmonary rehabilitation is an important treatment for patients with Chronic Obstructive Pulmonary Disease, who are often vitamin D deficient. As vitamin D status is linked to skeletal muscle function, we aimed to explore if high dose vitamin D supplementation can improve the outcomes of rehabilitation in Chronic Obstructive Pulmonary Disease. Material and methods: This study is a post-hoc subgroup analysis of a larger randomized trial comparing a monthly dose of 100.000 IU of vitamin D with placebo to reduce exacerbations. 50 Subjects who followed a rehabilitation program during the trial are included in this analysis. We report changes from baseline in muscle strength and exercise performance between both study arms after 3 months of rehabilitation. Results: Vitamin D intervention resulted in significantly higher median vitamin D levels compared to placebo (51 [44-62] ng/ml vs 15 [13-30] ng/ml; p < 0.001). Patients receiving vitamin D had significantly larger improvements in inspiratory muscle strength (-11±12 cmH2O vs 0±14 cmH2O; p = 0.004) and maximal oxygen uptake (110±211 ml/min vs -20±187 ml/min; p = 0.029). Improvements in quadriceps strength (15±16 Nm) or six minutes walking distance (40±55 meter) were not significantly different from the effects in the placebo group (7±19 Nm and 11±74 meter; p>0.050). Conclusion: High dose vitamin D supplementation during rehabilitation may have mild additional benefits to training.
- Open Access
- 9 July 2012
- Published by Springer Nature in International Journal of Behavioral Nutrition and Physical Activity
- Vol. 9 (1) , 84
Validity of activity monitors in health and chronic disease: a systematic review
The assessment of physical activity in healthy populations and in those with chronic diseases is challenging. The aim of this systematic review was to identify whether available activity monitors (AM) have been appropriately validated for use in assessing physical activity in these groups. Following a systematic literature search we found 134 papers meeting the inclusion criteria; 40 conducted in a field setting (validation against doubly labelled water), 86 in a laboratory setting (validation against a metabolic cart, metabolic chamber) and 8 in a field and laboratory setting. Correlation coefficients between AM outcomes and energy expenditure (EE) by the criterion method (doubly labelled water and metabolic cart/chamber) and percentage mean differences between EE estimation from the monitor and EE measurement by the criterion method were extracted. Random-effects meta-analyses were performed to pool the results across studies where possible. Types of devices were compared using meta-regression analyses. Most validation studies had been performed in healthy adults (n = 118), with few carried out in patients with chronic diseases (n = 16). For total EE, correlation coefficients were statistically significantly lower in uniaxial compared to multisensor devices. For active EE, correlations were slightly but not significantly lower in uniaxial compared to triaxial and multisensor devices. Uniaxial devices tended to underestimate TEE (−12.07 (95%CI; -18.28 to −5.85) %) compared to triaxial (−6.85 (95%CI; -18.20 to 4.49) %, p = 0.37) and were statistically significantly less accurate than multisensor devices (−3.64 (95%CI; -8.97 to 1.70) %, p<0.001). TEE was underestimated during slow walking speeds in 69% of the lab validation studies compared to 37%, 30% and 37% of the studies during intermediate, fast walking speed and running, respectively. The high level of heterogeneity in the validation studies is only partly explained by the type of activity monitor and the activity monitor outcome. Triaxial and multisensor devices tend to be more valid monitors. Since activity monitors are less accurate at slow walking speeds and information about validated activity monitors in chronic disease populations is lacking, proper validation studies in these populations are needed prior to their inclusion in clinical trials.
- 9 July 2012
- Published by Springer Nature in International Journal of Behavioral Nutrition and Physical Activity
- Vol. 9 (1) , 84
Open AccessValidity of activity monitors in health and chronic disease: a systematic review
The assessment of physical activity in healthy populations and in those with chronic diseases is challenging. The aim of this systematic review was to identify whether available activity monitors (AM) have been appropriately validated for use in assessing physical activity in these groups. Following a systematic literature search we found 134 papers meeting the inclusion criteria; 40 conducted in a field setting (validation against doubly labelled water), 86 in a laboratory setting (validation against a metabolic cart, metabolic chamber) and 8 in a field and laboratory setting. Correlation coefficients between AM outcomes and energy expenditure (EE) by the criterion method (doubly labelled water and metabolic cart/chamber) and percentage mean differences between EE estimation from the monitor and EE measurement by the criterion method were extracted. Random-effects meta-analyses were performed to pool the results across studies where possible. Types of devices were compared using meta-regression analyses. Most validation studies had been performed in healthy adults (n = 118), with few carried out in patients with chronic diseases (n = 16). For total EE, correlation coefficients were statistically significantly lower in uniaxial compared to multisensor devices. For active EE, correlations were slightly but not significantly lower in uniaxial compared to triaxial and multisensor devices. Uniaxial devices tended to underestimate TEE (−12.07 (95%CI; -18.28 to −5.85) %) compared to triaxial (−6.85 (95%CI; -18.20 to 4.49) %, p = 0.37) and were statistically significantly less accurate than multisensor devices (−3.64 (95%CI; -8.97 to 1.70) %, p<0.001). TEE was underestimated during slow walking speeds in 69% of the lab validation studies compared to 37%, 30% and 37% of the studies during intermediate, fast walking speed and running, respectively. The high level of heterogeneity in the validation studies is only partly explained by the type of activity monitor and the activity monitor outcome. Triaxial and multisensor devices tend to be more valid monitors. Since activity monitors are less accurate at slow walking speeds and information about validated activity monitors in chronic disease populations is lacking, proper validation studies in these populations are needed prior to their inclusion in clinical trials.