JHJustin L. Hodgins

Justin L. Hodgins

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Justin L. Hodgins has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Knee Arthroscopy Learning Curve: Quantitative Assessment of Surgical Skills

    by Justin L. Hodgins, Christian Veillette, David Biau, Ranil Sonnadara

    Purpose: To assess orthopaedic trainees performing diagnostic knee arthroscopies and evaluate procedural competence using a novel statistical method, the Cumulative Summation Test for Learning Curve (LC‐CUSUM). Methods: Twenty orthopaedic trainees in postgraduate year (PGY) 1 through 5 performed diagnostic knee arthroscopy and were evaluated intraoperatively with a validated 10‐point knee task‐specific checklist (TSCL) and 50‐point global rating scale (GRS). A score of 40 points or greater (of 50 points) for the GRS and 8 points or greater (of 10 points) for the knee TSCL was considered to indicate a successful procedure. For the LC‐CUSUM analysis, adequate performance was defined as a 10% failure rate, inadequate performance was defined as a 30% failure rate, and an acceptable deviation from adequate performance was defined as 10%. A limit h equal to 1.6 was selected to give a true‐discovery rate of 90% and a false‐discovery rate of 10% over 50 procedures. Results: A total of 340 consecutive procedures were performed by 20 trainees during the 12‐month study period. The cumulative number of arthroscopic procedures performed by trainees before study start increased with increasing PGY. The median number of arthroscopic procedures performed per trainee was 16.5 (interquartile range, 14 to 21.75). Competency in knee arthroscopy for the TSCL was achieved by 8 trainees (40%), after a median of 16 procedures (interquartile range, 13 to 20), and for the GRS by only a single trainee (5%), after 14 procedures. Threshold‐adjusted curves stratified by PGY level enabled multiple trainees to achieve competency for both the TSCL and GRS. Conclusions: The LC‐CUSUM can be successfully applied to knee arthroscopy to provide an individualized assessment of performance and quantitatively demonstrate competency for basic arthroscopic tasks. Clinical Relevance: The LC‐CUSUM is an effective method to evaluate procedure competence in arthroscopic training and can provide objective feedback and benchmarks in the learning phase.


  • Open Access

    Arthroscopic proficiency: methods in evaluating competency

    by Justin L Hodgins, Christian Veillette

    The current paradigm of arthroscopic training lacks objective evaluation oftechnical ability and its adequacy is concerning given the acceleratingcomplexity of the field. To combat insufficiencies, emphasis is shiftingtowards skill acquisition outside the operating room and sophisticatedassessment tools. We reviewed (1) the validity of cadaver and surgicalsimulation in arthroscopic training, (2) the role of psychomotor analysisand arthroscopic technical ability, (3) what validated assessment tools areavailable to evaluate technical competency, and (4) the quantification ofarthroscopic proficiency. The Medline and Embase databases were searched for published articles in theEnglish literature pertaining to arthroscopic competence, arthroscopicassessment and evaluation and objective measures of arthroscopic technicalskill. Abstracts were independently evaluated and exclusion criteriaincluded articles outside the scope of knee and shoulder arthroscopy as wellas original articles about specific therapies, outcomes and diagnosesleaving 52 articles citied in this review. Simulated arthroscopic environments exhibit high levels of internal validityand consistency for simple arthroscopic tasks, however the ability totransfer complex skills to the operating room has not yet been established.Instrument and force trajectory data can discriminate between technicalability for basic arthroscopic parameters and may serve as useful adjunctsto more comprehensive techniques. There is a need for arthroscopicassessment tools for standardized evaluation and objective feedback oftechnical skills, yet few comprehensive instruments exist, especially forthe shoulder. Opinion on the required arthroscopic experience to obtainproficiency remains guarded and few governing bodies specify absolutequantities. Further validation is required to demonstrate the transfer of complexarthroscopic skills from simulated environments to the operating room andprovide objective parameters to base evaluation. There is a deficiency ofvalidated assessment tools for technical competencies and little consensusof what constitutes a sufficient case volume within the arthroscopycommunity.