John Napier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Latest Publications
- Open Access
Climate Based Façade Design for Business Buildings with Examples from Central London
There is a disconnection between commercial architecture and environmental thinking, where green features can be included as part of a strategy for gaining approvals and marketing projects, but those features are not reviewed after completion and occupation of the building and knowledge is not shared. High levels of air conditioning are still considered unavoidable. Elaborate double skin façades and complex motorized shading systems are adopted; often masking an underlying lack of basic environmental thinking. This article returns (in principle) to the physics of comfort in buildings and the passive strategies which can help achieve this with a low energy and carbon footprint. Passive and active façade design strategies are outlined as the basis of a critical tool and a design methodology for new projects. A new architectural sensibility can arise based on modeling the inputs of sunlight, daylight and air temperature in time and space at the early stages of design. Early but sound strategies can be tested and refined using advanced environmental modeling techniques. Architecture and environmental thinking can proceed hand in hand through the design process.
Open AccessClimate Based Façade Design for Business Buildings with Examples from Central London
There is a disconnection between commercial architecture and environmental thinking, where green features can be included as part of a strategy for gaining approvals and marketing projects, but those features are not reviewed after completion and occupation of the building and knowledge is not shared. High levels of air conditioning are still considered unavoidable. Elaborate double skin façades and complex motorized shading systems are adopted; often masking an underlying lack of basic environmental thinking. This article returns (in principle) to the physics of comfort in buildings and the passive strategies which can help achieve this with a low energy and carbon footprint. Passive and active façade design strategies are outlined as the basis of a critical tool and a design methodology for new projects. A new architectural sensibility can arise based on modeling the inputs of sunlight, daylight and air temperature in time and space at the early stages of design. Early but sound strategies can be tested and refined using advanced environmental modeling techniques. Architecture and environmental thinking can proceed hand in hand through the design process.
- Open Access
Manchester Civil Justice Centre: Procuring and Managing an Institutional Building with a Mixed Mode Ventilation System—A Case for Post-Occupancy Evaluation
Manchester Civil Justice Centre is a striking contemporary 14 storey court building which has won awards for many different aspects of its design, construction and sustainability. From November 2002 to July 2005, the author was a key member of Denton Corker Marshall’s London project team having responsibility for key areas of design development, integration of technology and sustainable design including the East elevation’s “environmental veil”. This paper tracks the procurement of the building, describing its low energy features and their performance in practice. The paper reviews the low carbon elements of the design (daylight and natural ventilation systems) in the context of similar buildings and the buildings operational performance. The building has a mixed mode ventilation system which is managed centrally; the paper describes the ongoing relationship between the Facilities Management and the building’s users and their expectations of comfort and offers an explanation as to why the building’s energy performance is not as good as predicted at design stage. A case is made that this building is a significant example of low energy design and would form a good example for a detailed Post Occupancy Evaluation. The energy performance of the building could be studied in more detail to encourage the users (judges, staff and the public) to improve the building’s energy performance and to share knowledge within the construction industry. Institutional and commercial barriers to the more mainstream adoption of Post Occupancy Evaluation are discussed with respect to the Manchester Civil Justice Centre.
Open AccessManchester Civil Justice Centre: Procuring and Managing an Institutional Building with a Mixed Mode Ventilation System—A Case for Post-Occupancy Evaluation
Manchester Civil Justice Centre is a striking contemporary 14 storey court building which has won awards for many different aspects of its design, construction and sustainability. From November 2002 to July 2005, the author was a key member of Denton Corker Marshall’s London project team having responsibility for key areas of design development, integration of technology and sustainable design including the East elevation’s “environmental veil”. This paper tracks the procurement of the building, describing its low energy features and their performance in practice. The paper reviews the low carbon elements of the design (daylight and natural ventilation systems) in the context of similar buildings and the buildings operational performance. The building has a mixed mode ventilation system which is managed centrally; the paper describes the ongoing relationship between the Facilities Management and the building’s users and their expectations of comfort and offers an explanation as to why the building’s energy performance is not as good as predicted at design stage. A case is made that this building is a significant example of low energy design and would form a good example for a detailed Post Occupancy Evaluation. The energy performance of the building could be studied in more detail to encourage the users (judges, staff and the public) to improve the building’s energy performance and to share knowledge within the construction industry. Institutional and commercial barriers to the more mainstream adoption of Post Occupancy Evaluation are discussed with respect to the Manchester Civil Justice Centre.