Giuseppe De Roberto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Giuseppe De Roberto has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
G. Fiori
12 shared publicationsD. Ravizza
11 shared publications- Cristiano Crosta
European Institute of Oncology, Division of Endoscopy, Via Ripamonti 435, 20141 Milan, Italy
9 shared publications D. Tamayo
9 shared publications- Cristina Trovato
Division of Endoscopy, European Institute of Oncology, Milan, Italy
8 shared publications I. Bravi
4 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by Wolters Kluwer Health in ACG Case Reports Journal
- Vol. 13 (7)
Breaking the Size Barrier: Endoscopic Submucosal Dissection of a Massive Flat Gastric Neuroendocrine Tumor
Type I gastric neuroendocrine tumors, arising in chronic atrophic gastritis, are usually small, mucosal, or submucosal elevated lesions. Current guidelines recommend endoscopic resection of lesions ≤20 mm and surgical treatment for those >20 mm. We report an unusual case of a 56-year-old woman with a completely flat (Paris 0-IIb) gastric body neuroendocrine tumor (NET) measuring 140 × 35 mm, detected by virtual chromoendoscopy and successfully resected by endoscopic submucosal dissection without complications. Histology revealed about 40 well-differentiated low-grade NET foci. After 6 months, no recurrence occurred, confirming endoscopic submucosal dissections curative potential in this exceptional giant but flat NET case.
- 1 July 2026
- Published by Wolters Kluwer Health in ACG Case Reports Journal
- Vol. 13 (7)
Open AccessBreaking the Size Barrier: Endoscopic Submucosal Dissection of a Massive Flat Gastric Neuroendocrine Tumor
Type I gastric neuroendocrine tumors, arising in chronic atrophic gastritis, are usually small, mucosal, or submucosal elevated lesions. Current guidelines recommend endoscopic resection of lesions ≤20 mm and surgical treatment for those >20 mm. We report an unusual case of a 56-year-old woman with a completely flat (Paris 0-IIb) gastric body neuroendocrine tumor (NET) measuring 140 × 35 mm, detected by virtual chromoendoscopy and successfully resected by endoscopic submucosal dissection without complications. Histology revealed about 40 well-differentiated low-grade NET foci. After 6 months, no recurrence occurred, confirming endoscopic submucosal dissections curative potential in this exceptional giant but flat NET case.
- 1 February 2016
- Published by Elsevier in Digestive and Liver Disease
- Vol. 48, e173-e174
P.09.6 LONG TERM FOLLOW-UP OF RECURRENT/RESIDUAL COLORECTAL ADENOMAS AFTER ENDOSCOPIC SUBMUCOSAL DISSECTION: A SINGLE CENTER EXPERIENCE
- 1 February 2016
- Published by Elsevier in Digestive and Liver Disease
- Vol. 48, e173-e174
P.09.6 LONG TERM FOLLOW-UP OF RECURRENT/RESIDUAL COLORECTAL ADENOMAS AFTER ENDOSCOPIC SUBMUCOSAL DISSECTION: A SINGLE CENTER EXPERIENCE
- 1 March 2014
- Published by Elsevier in Digestive and Liver Disease
- Vol. 46, S135
P.21.1 ENDOSCOPIC ELECTROCAUTERY DILATION OF POST-SURGICAL BENIGN ANASTOMOTIC COLONIC STRICTURES: A SINGLE CENTER EXPERIENCE
- 1 March 2014
- Published by Elsevier in Digestive and Liver Disease
- Vol. 46, S135
P.21.1 ENDOSCOPIC ELECTROCAUTERY DILATION OF POST-SURGICAL BENIGN ANASTOMOTIC COLONIC STRICTURES: A SINGLE CENTER EXPERIENCE
- 1 March 2014
- Published by Elsevier in Digestive and Liver Disease
- Vol. 46, S106
P.13.16 HIGH DEFINITION PLUS COLONOSCOPY WITH I-SCAN VS STANDARD COLONOSCOPY: A SINGLE CENTRE EXPERIENCE
- 1 March 2014
- Published by Elsevier in Digestive and Liver Disease
- Vol. 46, S106
P.13.16 HIGH DEFINITION PLUS COLONOSCOPY WITH I-SCAN VS STANDARD COLONOSCOPY: A SINGLE CENTRE EXPERIENCE
- 1 March 2014
- Published by Elsevier in Digestive and Liver Disease
- Vol. 46, S49
V.01.9 ENDOSCOPIC SUBMUCOSAL DISSECTION FOR ANASTOMOTIC GASTRIC CANCER: A CASE REPORT
- 1 March 2014
- Published by Elsevier in Digestive and Liver Disease
- Vol. 46, S49
V.01.9 ENDOSCOPIC SUBMUCOSAL DISSECTION FOR ANASTOMOTIC GASTRIC CANCER: A CASE REPORT
- 10 February 2012
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 44 (S 02) , E51-E52
Stent migration after stent-in-stent technique using a biodegradable stent
Self-expanding metal stents (SEMS) seem to be the optimal choice for benign esophageal disorders, especially those not associated with a stricture, such as anastomotic leaks, iatrogenic perforations, and fistulas. On the other hand stent embedding can be an important limitation of SEMS placement, because this precludes safe stent removal [1]. In fact, in the literature there are only a few case series reporting the stent-in-stent technique using SEMS to remove embedded stents (14 – 189 days from the placement of the first stent) [2] [3]. We report a case of a 65-year-old woman who underwent total gastrectomy for adenocarcinoma and, 3 months later, dilation of an anastomotic fibrotic stricture complicated by a visceral tear and sepsis. This was treated by placement of an Ultraflex stent (Boston Scientific, Natick, Massachusetts, USA). After 6 months, the patient complained of dysphagia, and a second longer Ultraflex stent was placed inside the first one ([Fig. 1]). Because of the worsening of the patient’s dysphagia in the preceding 6 months, the patient was referred to our division. Over a 2-month period, the patient underwent two treatments of argon plasma coagulation to reduce the reactive tissue and granulomatosis involving the not-covered esophageal proximal end of the stent, with partial reduction of her dysphagia ([Fig. 2] and [Fig. 3]). We decided to remove the internal stent and place a biodegradable SX-ELLA BD stent (ELLA-CS, Milady Horakove, Czech Republic), overlapping the proximal segment of the first stent, in order to improve the patient’s quality of life ([Fig. 4]). The endoscopic checks at 15 and 45 days from stenting showed correct positioning and integrity of both the biodegradable and Ultraflex stents. At the third endoscopic check, after 3 months, neither stent was in place and the esophageal mucosa was completely re-epithelizated. It appeared that the biodegradable stent had been entirely absorbed, while the Ultraflex stent had migrated and been expelled with the stool because of pressure necrosis, arising from the biodegradable stent, of the overlying mucosa ([Fig. 5]). Two abdominal X-rays performed over 2 months confirmed the absence of radiopaque images relating to the first Ultraflex stent ([Fig. 6]). The patient’s dysphagia disappeared, allowing her to follow an unrestricted diet and gain 15 kg in weight. To our knowledge this is the first case reporting the stent-in-stent technique using a biodegradable stent with the unexpected result of spontaneous and late migration of a metal stent (600 days after placement). Endoscopy_UCTN_Code_CPL_1AH_2AD
- 10 February 2012
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 44 (S 02) , E51-E52
Stent migration after stent-in-stent technique using a biodegradable stent
Self-expanding metal stents (SEMS) seem to be the optimal choice for benign esophageal disorders, especially those not associated with a stricture, such as anastomotic leaks, iatrogenic perforations, and fistulas. On the other hand stent embedding can be an important limitation of SEMS placement, because this precludes safe stent removal [1]. In fact, in the literature there are only a few case series reporting the stent-in-stent technique using SEMS to remove embedded stents (14 – 189 days from the placement of the first stent) [2] [3]. We report a case of a 65-year-old woman who underwent total gastrectomy for adenocarcinoma and, 3 months later, dilation of an anastomotic fibrotic stricture complicated by a visceral tear and sepsis. This was treated by placement of an Ultraflex stent (Boston Scientific, Natick, Massachusetts, USA). After 6 months, the patient complained of dysphagia, and a second longer Ultraflex stent was placed inside the first one ([Fig. 1]). Because of the worsening of the patient’s dysphagia in the preceding 6 months, the patient was referred to our division. Over a 2-month period, the patient underwent two treatments of argon plasma coagulation to reduce the reactive tissue and granulomatosis involving the not-covered esophageal proximal end of the stent, with partial reduction of her dysphagia ([Fig. 2] and [Fig. 3]). We decided to remove the internal stent and place a biodegradable SX-ELLA BD stent (ELLA-CS, Milady Horakove, Czech Republic), overlapping the proximal segment of the first stent, in order to improve the patient’s quality of life ([Fig. 4]). The endoscopic checks at 15 and 45 days from stenting showed correct positioning and integrity of both the biodegradable and Ultraflex stents. At the third endoscopic check, after 3 months, neither stent was in place and the esophageal mucosa was completely re-epithelizated. It appeared that the biodegradable stent had been entirely absorbed, while the Ultraflex stent had migrated and been expelled with the stool because of pressure necrosis, arising from the biodegradable stent, of the overlying mucosa ([Fig. 5]). Two abdominal X-rays performed over 2 months confirmed the absence of radiopaque images relating to the first Ultraflex stent ([Fig. 6]). The patient’s dysphagia disappeared, allowing her to follow an unrestricted diet and gain 15 kg in weight. To our knowledge this is the first case reporting the stent-in-stent technique using a biodegradable stent with the unexpected result of spontaneous and late migration of a metal stent (600 days after placement). Endoscopy_UCTN_Code_CPL_1AH_2AD
- 31 March 2011
- Published by Elsevier in Digestive and Liver Disease
- Vol. 43, S197
P.1.150: DIAGNOSTIC ACCURACY OF ENDORECTAL LINEAR ARRAY ULTRASONOGRAPHY IN THE STAGING OF RECTAL NEOPLASIAS SUITABLE FOR LOCAL TREATMENT
- 31 March 2011
- Published by Elsevier in Digestive and Liver Disease
- Vol. 43, S197
P.1.150: DIAGNOSTIC ACCURACY OF ENDORECTAL LINEAR ARRAY ULTRASONOGRAPHY IN THE STAGING OF RECTAL NEOPLASIAS SUITABLE FOR LOCAL TREATMENT
- 31 March 2011
- Published by Elsevier in Digestive and Liver Disease
- Vol. 43, S261
P.1.342: BIODEGRADABLE STENTS FOR REFRACTORY BENIGN COLORECTAL POST-SURGICAL STRICTURES: FIRST EXPERIENCE
- 31 March 2011
- Published by Elsevier in Digestive and Liver Disease
- Vol. 43, S261
P.1.342: BIODEGRADABLE STENTS FOR REFRACTORY BENIGN COLORECTAL POST-SURGICAL STRICTURES: FIRST EXPERIENCE
- 31 March 2011
- Published by Elsevier in Digestive and Liver Disease
- Vol. 43, S155
P.1.21: EVALUATION OF A NEW REDUCED VOLUME BOWEL PREPARATION BEFORE COLONOSCOPY
- 31 March 2011
- Published by Elsevier in Digestive and Liver Disease
- Vol. 43, S155
P.1.21: EVALUATION OF A NEW REDUCED VOLUME BOWEL PREPARATION BEFORE COLONOSCOPY
- 7 October 2010
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 42 (S 02) , E267
Massive pneumoperitoneum after argon plasma coagulation
Argon plasma coagulation (APC) is a noncontact electrocoagulation technique widely used in the gastrointestinal tract. The rate of complications after APC is low even though colonic perforation has been reported after development of submucosal emphysema [ 1 ] [ 2 ]. We report the case of a 68-year old man who underwent endoscopic resection of a 3-cm nonpolypoid (IIa – IIc) lesion of the transverse colon ([ Fig. 1 ]). Fig. 1 Nonpolypoid (IIa – IIc) lesion in the transverse colon. His previous medical history was unremarkable, blood chemistry was normal, and he was not receiving any medications. The endoscopic procedure lasted approximately 2 hours and after a piecemeal mucosal resection using the “lift and cut” technique, APC was applied to the resection margins. Submucosal emphysema was not observed ([ Fig. 2 ]). Fig. 2 Post-mucosal resection ulcer after argon plasma coagulation (APC) treatment. Immediately after the procedure, the patient’s abdomen was distended without tenderness or any signs of peritonitis. After another 20 hours, because of the persisting abdominal distension, but no complaints on the part of the patient, an abdominal X-ray was taken, which demonstrated massive subdiaphragmatic free air ([ Fig. 3 a ]). Fig. 3 Massive presence of subdiaphragmatic air and its gradual resolution to complete disappearance on the radiographs: a 20 hours, b 1 month, and c 3 months after the procedure. After an uneventful period of waiting and watching for 2 days, the radiological picture was unchanged. The patient was discharged and 1 month later he underwent radiological follow-up, which showed marked reduction in the volume of the abdominal air ([ Fig. 3 b ]), and 3 months after the endoscopic procedure the air had completely disappeared ([ Fig. 3 c ]). The patient was asymptomatic throughout. In the literature, a few cases of pneumoperitoneum after APC application have been reported, and one patient underwent laparotomy [ 3 ]. Despite the massive abdominal distension, lasting at least 1 month, our patient did not report any symptoms and did not undergo any treatment except cautious observation. In this setting, it is mandatory to distinguish between the presence of abdominal free air caused by bowel perforation from that due to the passage of gas through the gut wall. The latter, even if longlasting, does not trigger any complaint in our experience and can be managed conservatively. Competing interests: None Endoscopy_UCTN_Code_CPL_1AJ_2AI
- 7 October 2010
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 42 (S 02) , E267
Massive pneumoperitoneum after argon plasma coagulation
Argon plasma coagulation (APC) is a noncontact electrocoagulation technique widely used in the gastrointestinal tract. The rate of complications after APC is low even though colonic perforation has been reported after development of submucosal emphysema [ 1 ] [ 2 ]. We report the case of a 68-year old man who underwent endoscopic resection of a 3-cm nonpolypoid (IIa – IIc) lesion of the transverse colon ([ Fig. 1 ]). Fig. 1 Nonpolypoid (IIa – IIc) lesion in the transverse colon. His previous medical history was unremarkable, blood chemistry was normal, and he was not receiving any medications. The endoscopic procedure lasted approximately 2 hours and after a piecemeal mucosal resection using the “lift and cut” technique, APC was applied to the resection margins. Submucosal emphysema was not observed ([ Fig. 2 ]). Fig. 2 Post-mucosal resection ulcer after argon plasma coagulation (APC) treatment. Immediately after the procedure, the patient’s abdomen was distended without tenderness or any signs of peritonitis. After another 20 hours, because of the persisting abdominal distension, but no complaints on the part of the patient, an abdominal X-ray was taken, which demonstrated massive subdiaphragmatic free air ([ Fig. 3 a ]). Fig. 3 Massive presence of subdiaphragmatic air and its gradual resolution to complete disappearance on the radiographs: a 20 hours, b 1 month, and c 3 months after the procedure. After an uneventful period of waiting and watching for 2 days, the radiological picture was unchanged. The patient was discharged and 1 month later he underwent radiological follow-up, which showed marked reduction in the volume of the abdominal air ([ Fig. 3 b ]), and 3 months after the endoscopic procedure the air had completely disappeared ([ Fig. 3 c ]). The patient was asymptomatic throughout. In the literature, a few cases of pneumoperitoneum after APC application have been reported, and one patient underwent laparotomy [ 3 ]. Despite the massive abdominal distension, lasting at least 1 month, our patient did not report any symptoms and did not undergo any treatment except cautious observation. In this setting, it is mandatory to distinguish between the presence of abdominal free air caused by bowel perforation from that due to the passage of gas through the gut wall. The latter, even if longlasting, does not trigger any complaint in our experience and can be managed conservatively. Competing interests: None Endoscopy_UCTN_Code_CPL_1AJ_2AI