RNRikke Norling

Rikke Norling

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rikke Norling has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of Transoral and Transcervical Ultrasonography with MRI for the Diagnostic Work-Up of Oropharynx Tumors: A Protocol for a Multicenter Clinical Trial (SPOTUS)

    by Martin Garset-Zamani, Gitte Bjørn Hvilsom, Thomas Kjærgaard, Christina Caroline Plaschke, Christoffer Holst Hahn, Mikkel Kaltoft, Padraig O’leary, Natalie Lassen Frid, Rikke Norling, Danijela Dejanovic, et al.

    This study protocol for a prospective, multicenter, diagnostic, clinical trial describes the integration of transoral and transcervical ultrasonography (US) in the initial clinical work-up of patients referred to tertiary head and neck cancer centers with suspected oropharyngeal cancer. The study evaluates the blinded detection rate of oropharyngeal tumors and their US-estimated size and T-stage before histopathology and cross-sectional imaging are available. Magnetic resonance imaging (MRI) scans will be prospectively rated while blinded to T-site histopathology and US. The primary outcome measures of diagnostic accuracy, including sensitivity, specificity, positive and negative predictive values, and overall accuracy, will be reported for both US and MRI. A sub-analysis of prospectively rated 18F-Fluorodeoxyglucose (FDG) positron emission tomography/computerized tomography (PET/CT) scans in patients with clinically suspected unknown primary tumors will also be compared to US and MRI. Secondary outcome measures, including a comparison of tumor size estimation between US, MRI, and CT, will also be reported. This prospective multicenter study will provide clinically impactful information regarding the use of transoral and transcervical US for the diagnostic work-up of oropharyngeal cancer.


  • Open Access

    Transoral Ultrasound in the Outpatient Clinic for the Diagnostic Work-Up of Oropharyngeal Cancer: A Feasibility Study

    by Martin Garset-Zamani, Rikke Norling, Christoffer Holst Hahn, Tina Klitmøller Agander, Christian von Buchwald, Tobias Todsen

    Magnetic resonance imaging (MRI) is the preferred imaging modality for oropharyngeal cancers (OPCs), but it has difficulties distinguishing between small OPCs and unilateral tonsil hypertrophy. We hypothesized that surgeon-performed transoral ultrasound (US) could be used to accurately detect T-stage OPCs. We performed a single-center prospective diagnostic accuracy study including patients with suspected or biopsy-verified OPCs during outpatient appointments. All patients were offered transoral US and MRI. If transoral US could not be tolerated by the patient, transcervical US was performed. The primary outcome was the diagnostic accuracy of detecting OPCs with US compared to MRI, using histopathology as the reference standard. The secondary outcome was comparing the primary tumor diameters between US and MRI blinded to each other. Out of the 26 patients included in the study, 21 (81%) had OPCs. Transoral US could be performed in 21/21 and 1/5 patients with suspected palatine and lingual tonsil OPCs, respectively. Overall, US diagnostic accuracy was 92%, compared to 81% with MRI (p = 0.37). US and MRI had a high correlation between tumor diameters in the anteroposterior diameter (R = 0.80, p < 0.001), corresponding to the depth axis on US. In conclusion, this small study showed the promise and feasibility of transoral US to improve the initial clinical evaluations of patients with suspected OPCs.


  • Open Access

    3D Ultrasound and MRI in Assessing Resection Margins during Tongue Cancer Surgery: A Research Protocol for a Clinical Diagnostic Accuracy Study

    by Fatemeh Makouei, Tina Klitmøller Agander, Caroline Ewertsen, Morten Bo Søndergaard Svendsen, Rikke Norling, Mikkel Kaltoft, Adam Espe Hansen, Jacob Høygaard Rasmussen, Irene Wessel, Tobias Todsen

    Surgery is the primary treatment for tongue cancer. The goal is a complete resection of the tumor with an adequate margin of healthy tissue around the tumor.Inadequate margins lead to a high risk of local cancer recurrence and the need for adjuvant therapies. Ex vivo imaging of the resected surgical specimen has been suggested for margin assessment and improved surgical results. Therefore, we have developed a novel three-dimensional (3D) ultrasound imaging technique to improve the assessment of resection margins during surgery. In this research protocol, we describe a study comparing the accuracy of 3D ultrasound, magnetic resonance imaging (MRI), and clinical examination of the surgical specimen to assess the resection margins during cancer surgery. Tumor segmentation and margin measurement will be performed using 3D ultrasound and MRI of the ex vivo specimen. We will determine the accuracy of each method by comparing the margin measurements and the proportion of correctly classified margins (positive, close, and free) obtained by each technique with respect to the gold standard histopathology.


  • Nodal yield in selective neck dissection

    by Rikke Norling, Marianne H. Therkildsen, Patrick J. Bradley, Michael B. Nielsen, Christian von Buchwald

    Conclusion: The total lymph node yield in neck dissection is highly variable and depends on anatomical, surgical and pathological parameters. A minimum yield of six lymph nodes for a selective neck dissection (SND) as recommended in guidelines lies in the lower range of the reported clinical nodal yields. A future application of a lymph node ratio may improve the risk stratification of head and neck cancer patients. However, this will require a higher number of retrieved lymph nodes. Objectives: To compare the clinical guideline recommendations for nodal yield in SND with the number of lymph nodes obtained from cadavers and the clinical nodal yield reported in the literature. Methods: Lymph nodes retrieved from SND specimens from nine fresh cadavers were quantified histopathologically. The literature on nodal yields reportedly obtained by clinicians performing neck dissections was reviewed. Finally, the discussion makes reference to the six lymph nodes currently recommended in international clinical guidelines. Results: For clinical SNDs (I–III) the lowest mean nodal yield was 19.4, for SNDs (II–IV) it was 26.4. The cadaver SNDs (I–III and II–IV) yielded 8.8 (range 1–15) and 10.4 nodes (range 1–19), respectively.


  • Open Access

    Computed Tomography (CT) Perfusion in Abdominal Cancer: Technical Aspects

    by Martin Lundsgaard Hansen, Rikke Norling, Carsten Lauridsen, Eva Fallentin, Lene Bæksgaard, Klaus Fuglsang Kofoed, Lars Bo Svendsen, Michael Bachmann Nielsen

    Computed Tomography (CT) Perfusion is an evolving method to visualize perfusion in organs and tissue. With the introduction of multidetector CT scanners, it is now possible to cover up to 16 cm in one rotation, and thereby making it possible to scan entire organs such as the liver with a fixed table position. Advances in reconstruction algorithms make it possible to reduce the radiation dose for each examination to acceptable levels. Regarding abdominal imaging, CT perfusion is still considered a research tool, but several studies have proven it as a reliable non-invasive technique for assessment of vascularity. CT perfusion has also been used for tumor characterization, staging of disease, response evaluation of newer drugs targeted towards angiogenesis and as a method for early detection of recurrence after radiation and embolization. There are several software solutions available on the market today based on different perfusion algorithms. However, there is no consensus on which protocol and algorithm to use for specific organs. In this article, the authors give an introduction to CT perfusion in abdominal imaging introducing technical aspects for calculation of perfusion parameters, and considerations on patient preparation. This article also contains clinical cases to illustrate the use of CT perfusion in abdominal imaging.