Jurek Duszczyk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jurek Duszczyk has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Laurens Katgerman
Delft University of Technology
2 shared publications - Lidy Elena Fratila-Apachitei
Department of Biomechanical Engineering Faculty of Mechanical Engineering Delft University of Technology (TU Delft) Mekelweg 2 Delft 2628 CD The Netherlands
2 shared publications - H. J. Brinkman
Laboratory of Materials Science, Delft University of Technology, Delft, The Netherlands
1 shared publication - Iulian Apachitei
Department of Biomechanical Engineering, Faculty of Mechanical Engineering, Delft University of Technology
1 shared publication - L E Fratila-Apachitei
Department of Materials Science and Engineering, Delft University of Technology, Delft, The Netherlands
1 shared publication L. Katgerman
1 shared publication
Latest Publications
- 9 January 2014
- Published by IOP Publishing in Nanotechnology
- Vol. 25 (5) , 055602
Synthesis and characterization of hybrid micro/nano-structured NiTi surfaces by a combination of etching and anodizing
The purpose of this study was to generate hybrid micro/nano-structures on biomedical nickel-titanium alloy (NiTi). To achieve this, NiTi surfaces were firstly electrochemically etched and then anodized in fluoride-containing electrolyte. With the etching process, the NiTi surface was micro-roughened through the formation of micropits uniformly distributed over the entire surface. Following the subsequent anodizing process, self-organized nanotube structures enriched in TiO2 could be superimposed on the etched surface under specific conditions. Furthermore, the anodizing treatment significantly reduced water contact angles and increased the surface free energy compared to the surfaces prior to anodizing. The results of this study show for the first time that it is possible to create hybrid micro/nano-structures on biomedical NiTi alloys by combining electrochemical etching and anodizing under controlled conditions. These novel structures are expected to significantly enhance the surface biofunctionality of the material when compared to conventional implant devices with either micro- or nano-structured surfaces.
- 9 January 2014
- Published by IOP Publishing in Nanotechnology
- Vol. 25 (5) , 055602
Synthesis and characterization of hybrid micro/nano-structured NiTi surfaces by a combination of etching and anodizing
The purpose of this study was to generate hybrid micro/nano-structures on biomedical nickel-titanium alloy (NiTi). To achieve this, NiTi surfaces were firstly electrochemically etched and then anodized in fluoride-containing electrolyte. With the etching process, the NiTi surface was micro-roughened through the formation of micropits uniformly distributed over the entire surface. Following the subsequent anodizing process, self-organized nanotube structures enriched in TiO2 could be superimposed on the etched surface under specific conditions. Furthermore, the anodizing treatment significantly reduced water contact angles and increased the surface free energy compared to the surfaces prior to anodizing. The results of this study show for the first time that it is possible to create hybrid micro/nano-structures on biomedical NiTi alloys by combining electrochemical etching and anodizing under controlled conditions. These novel structures are expected to significantly enhance the surface biofunctionality of the material when compared to conventional implant devices with either micro- or nano-structured surfaces.
- Open Access
- 11 May 2012
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 3 (2) , 349-360
Characterization of Porous TiO2 Surfaces Formed on 316L Stainless Steel by Plasma Electrolytic Oxidation for Stent Applications
In this study, a porous oxide layer was formed on the surface of 316L stainless steel (SS) by combining Ti magnetron sputtering and plasma electrolytic oxidation (PEO) with the aim to produce a polymer-free drug carrier for drug eluting stent (DES) applications. The oxidation was performed galvanostatically in Na3PO4 electrolyte. The surface porosity, average pore size and roughness varied with PEO treatment duration, and under optimum conditions, the surface showed a porosity of 7.43%, an average pore size of 0.44 µm and a roughness (Ra) of 0.34 µm. The EDS analyses revealed that the porous layer consisted of Ti, O and P. The cross-sectional morphology evidenced a double-layer structure, with a porous titania surface and an un-oxidized dense Ti film towards the interface with 316L SS. After the PEO treatment, wettability and surface free energy increased significantly. The results of the present study confirm the feasibility of forming a porous TiO2 layer on stainless steel by combining sputtering technology and PEO. Further, the resultant porous oxide layer has the potential to be used as a drug carrier for DES, thus avoiding the complications associated with the polymer based carriers.
- 11 May 2012
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 3 (2) , 349-360
Open AccessCharacterization of Porous TiO2 Surfaces Formed on 316L Stainless Steel by Plasma Electrolytic Oxidation for Stent Applications
In this study, a porous oxide layer was formed on the surface of 316L stainless steel (SS) by combining Ti magnetron sputtering and plasma electrolytic oxidation (PEO) with the aim to produce a polymer-free drug carrier for drug eluting stent (DES) applications. The oxidation was performed galvanostatically in Na3PO4 electrolyte. The surface porosity, average pore size and roughness varied with PEO treatment duration, and under optimum conditions, the surface showed a porosity of 7.43%, an average pore size of 0.44 µm and a roughness (Ra) of 0.34 µm. The EDS analyses revealed that the porous layer consisted of Ti, O and P. The cross-sectional morphology evidenced a double-layer structure, with a porous titania surface and an un-oxidized dense Ti film towards the interface with 316L SS. After the PEO treatment, wettability and surface free energy increased significantly. The results of the present study confirm the feasibility of forming a porous TiO2 layer on stainless steel by combining sputtering technology and PEO. Further, the resultant porous oxide layer has the potential to be used as a drug carrier for DES, thus avoiding the complications associated with the polymer based carriers.
- 1 September 2006
- Published by Elsevier in Journal of Materials Processing Technology
- Vol. 178 (1-3) , 194-199
The effect of constitutive description of PIM feedstock viscosity in numerical analysis of the powder injection moulding process
- 1 September 2006
- Published by Elsevier in Journal of Materials Processing Technology
- Vol. 178 (1-3) , 194-199
The effect of constitutive description of PIM feedstock viscosity in numerical analysis of the powder injection moulding process
- 1 July 2000
- Published by Taylor & Francis in International Journal of Cast Metals Research
- Vol. 13 (1) , 59-65
Casting characteristics of high silicon added F3S.20S Duralcan composites
Fluidity and castability studies were carried out for F3S.20S (Al-20SiCp) Duralcan composites with additional amounts of silicon. The fluidity measurements were carried out using the gravity casting method and the castability studies using Low Pressure Casting (LPC) as well as gravity pouring methods. It was observed that with both the gravity and LPC methods, the fluidity and castability were found to increase, with the increasing silicon levels (up to 20 wt%) present in the composites. The castability of the composite was increased with each increase in temperature for the range of temperatures studied (1003,1013 and 1033 K).
- 1 July 2000
- Published by Taylor & Francis in International Journal of Cast Metals Research
- Vol. 13 (1) , 59-65
Casting characteristics of high silicon added F3S.20S Duralcan composites
Fluidity and castability studies were carried out for F3S.20S (Al-20SiCp) Duralcan composites with additional amounts of silicon. The fluidity measurements were carried out using the gravity casting method and the castability studies using Low Pressure Casting (LPC) as well as gravity pouring methods. It was observed that with both the gravity and LPC methods, the fluidity and castability were found to increase, with the increasing silicon levels (up to 20 wt%) present in the composites. The castability of the composite was increased with each increase in temperature for the range of temperatures studied (1003,1013 and 1033 K).
- 1 September 1998
- Published by Maney Publishing in Materials Science and Technology
- Vol. 14 (9) , 873-876
Influence of matrix alloying elements on reactive synthesis of 2124 aluminium alloy metal matrix composites
- 1 September 1998
- Published by Maney Publishing in Materials Science and Technology
- Vol. 14 (9) , 873-876
Influence of matrix alloying elements on reactive synthesis of 2124 aluminium alloy metal matrix composites