Markus Thommes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Markus Thommes has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Christian Muehlenfeld
Institute of Pharmaceutics and Biopharmaceutics, Heinrich-Heine-University, Duesseldorf, Germany
3 shared publicationsMartin Koester
Institute of Pharmaceutics and Biopharmaceutics, Heinrich Heine University, Duesseldorf, Germany
3 shared publicationsPeter Kleinebudde
Institute of Pharmaceutics and Biopharmaceutics, Heinrich-Heine-University, Duesseldorf, Germany
2 shared publications- Birthe Kann
Saarland University, Department of Biopharmaceutics and Pharmaceutical Technology, Campus A4.1, 66123 Saarbruecken, Germany
1 shared publication Chris Vervaet
Laboratory of Pharmaceutical Technology, Ghent University, Ghent, Belgium
1 shared publicationCornelia Krueger
Institute of Pharmaceutics and Biopharmaceutics, Heinrich-Heine-University, Duesseldorf, Germany
1 shared publication
Latest Publications
- 1 December 2014
- Published by Oxford University Press (OUP) in Journal of Pharmacy and Pharmacology
- Vol. 66 (12) , 1667-1676
Small-scale twin-screw extrusion – evaluation of continuous split feeding
Objectives: The aim of this work was to evaluate a continuous, small-scale extrusion process with a particular focus on powder and liquid-feeding systems, because it is likely that uniformity issues are related to small-scale production. Methods: The study is divided into three parts. The first part investigates the uniformity and accuracy of the powder and the liquid feeders. In the second part, a solid polymer and low amounts of liquid plasticizer were combined in hot-melt extrusion. The third part deals with wet extrusion-spheronization using water as the granulation liquid. Key Findings: The powder and the liquid feed rate were identified as crucial parameters in small-scale extrusion. With respect to powder feeding, the cohesiveness of the powder and electrostatic charging are the limitations, while liquid feeding is challenging based on particularly low feed rates. The hot-melt extrusion was performed using a powder feed rate of 2 g/min. When small quantities of plasticizer were applied to the hot melt extrusions (from 2.5% to 15% w/w), homogenous plasticizer distribution was found. In wet extrusion, larger quantities of water were used and the extrudates were investigated with respect to their spheronization behaviour. Spherical pellets were obtained at certain water contents. Conclusions: These findings demonstrated that the extruder is a useful tool to screen formulations and perform feasibility studies on a small scale in the early stages of product development.
- 1 December 2014
- Published by Oxford University Press (OUP) in Journal of Pharmacy and Pharmacology
- Vol. 66 (12) , 1667-1676
Small-scale twin-screw extrusion – evaluation of continuous split feeding
Objectives: The aim of this work was to evaluate a continuous, small-scale extrusion process with a particular focus on powder and liquid-feeding systems, because it is likely that uniformity issues are related to small-scale production. Methods: The study is divided into three parts. The first part investigates the uniformity and accuracy of the powder and the liquid feeders. In the second part, a solid polymer and low amounts of liquid plasticizer were combined in hot-melt extrusion. The third part deals with wet extrusion-spheronization using water as the granulation liquid. Key Findings: The powder and the liquid feed rate were identified as crucial parameters in small-scale extrusion. With respect to powder feeding, the cohesiveness of the powder and electrostatic charging are the limitations, while liquid feeding is challenging based on particularly low feed rates. The hot-melt extrusion was performed using a powder feed rate of 2 g/min. When small quantities of plasticizer were applied to the hot melt extrusions (from 2.5% to 15% w/w), homogenous plasticizer distribution was found. In wet extrusion, larger quantities of water were used and the extrudates were investigated with respect to their spheronization behaviour. Spherical pellets were obtained at certain water contents. Conclusions: These findings demonstrated that the extruder is a useful tool to screen formulations and perform feasibility studies on a small scale in the early stages of product development.
- 1 November 2013
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 102 (11) , 4132-4139
Solid Dispersions Prepared by Continuous Cogrinding in an Air Jet Mill
- 1 November 2013
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 102 (11) , 4132-4139
Solid Dispersions Prepared by Continuous Cogrinding in an Air Jet Mill
- 1 February 2013
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 83 (2) , 307-314
Analysis of particle kinematics in spheronization via particle image velocimetry
- 1 February 2013
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 83 (2) , 307-314
Analysis of particle kinematics in spheronization via particle image velocimetry
- 1 February 2013
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 83 (2) , 193-202
Solid crystal suspensions containing griseofulvin – Preparation and bioavailability testing
- 1 February 2013
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 83 (2) , 193-202
Solid crystal suspensions containing griseofulvin – Preparation and bioavailability testing
- Open Access
- 6 November 2012
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 2 (4) , 217-231
Individual Oral Therapy with Immediate Release and Effervescent Formulations Delivered by the Solid Dosage Pen
New devices enabling freely selectable dosing of solid oral medications are urgently needed for personalized medicine. One approach is the use of the recently published Solid Dosage Pen, allowing flexible dosing of tablet-like sustained release slices from drug loaded extruded strands. Slices were suitable for oral single dosed application. The aim of the present study was the development of immediate release dosage forms for applications of the device, especially for young children. Using two model drugs, two different concepts were investigated and evaluated. Effervescent formulations were manufactured by an organic wet-extrusion process and immediate release formulations by a melt-extrusion process. Dissolution experiments were performed for both formulations to ensure the immediate release behavior. Extruded strands were individually dosed by the Solid Dosage Pen. Various doses of the two formulations were analyzed regarding uniformity of mass and content according to pharmacopoeial specifications. Proof of concept was demonstrated in both approaches as results comply with the regulatory requirements. Furthermore, storing stress tests were performed and drug formulations were characterized after storing. The results show that suitable packaging material has been selected and storage stability is probable.
- 6 November 2012
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 2 (4) , 217-231
Open AccessIndividual Oral Therapy with Immediate Release and Effervescent Formulations Delivered by the Solid Dosage Pen
New devices enabling freely selectable dosing of solid oral medications are urgently needed for personalized medicine. One approach is the use of the recently published Solid Dosage Pen, allowing flexible dosing of tablet-like sustained release slices from drug loaded extruded strands. Slices were suitable for oral single dosed application. The aim of the present study was the development of immediate release dosage forms for applications of the device, especially for young children. Using two model drugs, two different concepts were investigated and evaluated. Effervescent formulations were manufactured by an organic wet-extrusion process and immediate release formulations by a melt-extrusion process. Dissolution experiments were performed for both formulations to ensure the immediate release behavior. Extruded strands were individually dosed by the Solid Dosage Pen. Various doses of the two formulations were analyzed regarding uniformity of mass and content according to pharmacopoeial specifications. Proof of concept was demonstrated in both approaches as results comply with the regulatory requirements. Furthermore, storing stress tests were performed and drug formulations were characterized after storing. The results show that suitable packaging material has been selected and storage stability is probable.
- 11 July 2012
- Published by Taylor & Francis in Pharmaceutical Development and Technology
- Vol. 18 (1) , 225-235
Multiple batch manufacturing of theophylline pellets using the wet-extrusion/spheronization process with κ-carrageenan as pelletisation aid
κ-Carrageenan has been suggested as a pelletisation aid for wet-extrusion/spheronization processes for several years. Until now there have been no systematic investigations regarding process development and stability for long-term production. The aim of this study was to develop a high drug-loaded pellet formulation with κ-carrageenan, so that a robust process cycle occurred over the course of several hours. Binary mixtures of κ-carrageenan and theophylline monohydrate were used and the drug content was varied from 90 to 95%. A twin-screw extruder was used; the power consumption and feed rates were recorded. The pellets were characterized by aspect ratio, diameter, 10% interval, tensile strength and dissolution behavior. The process ran on two occasions for 4.5 h each time. During the extrusion process neither the power consumption nor the feed rates differed significantly, so there was no need to stop the process or change the extrusion parameters. Regarding the spheronization, a cleaning of the spheroniser friction plate was necessary every five batches due to packing of the material on this plate. Overall the resulting pellets showed reproducible and adequate qualities regarding all investigated properties. In conclusion a robust pelletisation process over several hours could be verified. It was possible to produce 42 kg of pellets with adequate properties, without any problems during the process.
- 11 July 2012
- Published by Taylor & Francis in Pharmaceutical Development and Technology
- Vol. 18 (1) , 225-235
Multiple batch manufacturing of theophylline pellets using the wet-extrusion/spheronization process with κ-carrageenan as pelletisation aid
κ-Carrageenan has been suggested as a pelletisation aid for wet-extrusion/spheronization processes for several years. Until now there have been no systematic investigations regarding process development and stability for long-term production. The aim of this study was to develop a high drug-loaded pellet formulation with κ-carrageenan, so that a robust process cycle occurred over the course of several hours. Binary mixtures of κ-carrageenan and theophylline monohydrate were used and the drug content was varied from 90 to 95%. A twin-screw extruder was used; the power consumption and feed rates were recorded. The pellets were characterized by aspect ratio, diameter, 10% interval, tensile strength and dissolution behavior. The process ran on two occasions for 4.5 h each time. During the extrusion process neither the power consumption nor the feed rates differed significantly, so there was no need to stop the process or change the extrusion parameters. Regarding the spheronization, a cleaning of the spheroniser friction plate was necessary every five batches due to packing of the material on this plate. Overall the resulting pellets showed reproducible and adequate qualities regarding all investigated properties. In conclusion a robust pelletisation process over several hours could be verified. It was possible to produce 42 kg of pellets with adequate properties, without any problems during the process.
- 14 March 2012
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 13 (2) , 493-497
Quantification of Mass Transfer During Spheronisation
- 14 March 2012
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 13 (2) , 493-497
Quantification of Mass Transfer During Spheronisation
- 9 December 2011
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 13 (1) , 94-100
Miniaturization in Pharmaceutical Extrusion Technology: Feeding as a Challenge of Downscaling
In recent years, extrusion technology has shifted the focus of pharmaceutical research due to versatile applications like pelletization, bioavailability improvement or manipulation of solid-state properties of drugs, continuous granulation, and the development of novel solid dosage forms. Meanwhile, a major effort has been devoted to the miniaturization of equipment in pharmaceutical extrusion technology, particularly with regard to the requirements of the development of new chemical entities and formulations. In the present study, a lab-scale twin-screw extruder was investigated in order to determine the limitations imposed by the feeding systems. The wet extrusion process was considered as challenging because both a powder and a liquid feeder have to be considered. Initially, the accuracy and uniformity of the powder and liquid feeder were tested independently of the extrusion process. After modification of the powder feeder, both feeders were investigated in conjunction with extrusion. Based on this, an optimization of the liquid feeder was required and completed. Both feeder modifications reduced the variability of the moisture content in the extrudates 10-fold. This led to a reliable small-scale extrusion process.
- 9 December 2011
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 13 (1) , 94-100
Miniaturization in Pharmaceutical Extrusion Technology: Feeding as a Challenge of Downscaling
In recent years, extrusion technology has shifted the focus of pharmaceutical research due to versatile applications like pelletization, bioavailability improvement or manipulation of solid-state properties of drugs, continuous granulation, and the development of novel solid dosage forms. Meanwhile, a major effort has been devoted to the miniaturization of equipment in pharmaceutical extrusion technology, particularly with regard to the requirements of the development of new chemical entities and formulations. In the present study, a lab-scale twin-screw extruder was investigated in order to determine the limitations imposed by the feeding systems. The wet extrusion process was considered as challenging because both a powder and a liquid feeder have to be considered. Initially, the accuracy and uniformity of the powder and liquid feeder were tested independently of the extrusion process. After modification of the powder feeder, both feeders were investigated in conjunction with extrusion. Based on this, an optimization of the liquid feeder was required and completed. Both feeder modifications reduced the variability of the moisture content in the extrudates 10-fold. This led to a reliable small-scale extrusion process.
- Open Access
- 1 March 2011
- Published by MDPI AG
Preliminary Assesments of Solid Crystal Suspensions Using Nonlinearmicroscopy
A few years ago Solid Crystal Suspensions (SCS), made via hot-melt-extrusion, were proposed as sufficient technique to increase the bioavailability of poorly soluble drugs of BCS Class II. The drug particle size and the dispersity of these systems are crucial properties because they determine the drug release. The nonlinear imaging techniques, Coherent Anti Stokes Raman Scattering (CARS) and Second Harmonic generation (SHG) microscopy, were used to characterize SCS in order to understand the dissolution behaviour of different formulations. CARS microscopy is based on the detection of molecular vibrations similar to Raman spectroscopy. The advantage in comparison to conventional Raman spectroscopy is the detection of a single vibrational resonance allowing for much faster imaging with CARS. The setup consists of a laser and an optical parametric oscillator. The beams were scanned over the sample by galvano-mirrors and focused by an objective lens into the sample. The generated CARS signal is shifted to a higher frequency in comparison to the incident beam. The SHG signal is created when the sample contains non-centrosymmetric structures. The generated signal is created simultaneous with the CARS signal in the sample and detected on a different detector. The SCS consisted of drug (Griseofulvin) and matrix (Mannitol). The matrix is detected with CARS microscopy and the drug with SHG microscopy offering high contrast between the compounds. The nonlinear microscopy images of the SCS showed a homogeneous distribution of the drug particles. There were no agglomerates and the drug distribution in the centre was almost the same as at the surface of the objects. The drug particle size was also investigated and similar results like in laser diffraction were found. The combination of the two nonlinear microscopy techniques, CARS and SHG where identified as promising tools to characterize drug distribution and drug particle size in this Solid Crystal Suspension.
- 1 March 2011
- Published by MDPI AG
Open AccessPreliminary Assesments of Solid Crystal Suspensions Using Nonlinearmicroscopy
A few years ago Solid Crystal Suspensions (SCS), made via hot-melt-extrusion, were proposed as sufficient technique to increase the bioavailability of poorly soluble drugs of BCS Class II. The drug particle size and the dispersity of these systems are crucial properties because they determine the drug release. The nonlinear imaging techniques, Coherent Anti Stokes Raman Scattering (CARS) and Second Harmonic generation (SHG) microscopy, were used to characterize SCS in order to understand the dissolution behaviour of different formulations. CARS microscopy is based on the detection of molecular vibrations similar to Raman spectroscopy. The advantage in comparison to conventional Raman spectroscopy is the detection of a single vibrational resonance allowing for much faster imaging with CARS. The setup consists of a laser and an optical parametric oscillator. The beams were scanned over the sample by galvano-mirrors and focused by an objective lens into the sample. The generated CARS signal is shifted to a higher frequency in comparison to the incident beam. The SHG signal is created when the sample contains non-centrosymmetric structures. The generated signal is created simultaneous with the CARS signal in the sample and detected on a different detector. The SCS consisted of drug (Griseofulvin) and matrix (Mannitol). The matrix is detected with CARS microscopy and the drug with SHG microscopy offering high contrast between the compounds. The nonlinear microscopy images of the SCS showed a homogeneous distribution of the drug particles. There were no agglomerates and the drug distribution in the centre was almost the same as at the surface of the objects. The drug particle size was also investigated and similar results like in laser diffraction were found. The combination of the two nonlinear microscopy techniques, CARS and SHG where identified as promising tools to characterize drug distribution and drug particle size in this Solid Crystal Suspension.
- 23 February 2011
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 8 (3) , 727-735
Improvement of the Dissolution Rate of Poorly Soluble Drugs by Solid Crystal Suspensions
We present a novel extrusion based approach where the dissolution rate of poorly soluble drugs (griseofulvin, phenytoin and spironolactone) is significantly accelerated. The drug and highly soluble mannitol are coprocessed in a hot melt extrusion operation. The obtained product is an intimate mixture of the crystalline drug and crystalline excipient, with up to 50% (w/w) drug load. The in vitro drug release from the obtained solid crystalline suspensions is over 2 orders of magnitude faster than that of the pure drug. Since the resulting product is crystalline, the accelerated dissolution rate does not bear the physical stability concerns inherent to amorphous formulations. This approach is useful in situations where the drug is not a good glass former or in cases where it is difficult to stabilize the amorphous drug. Being thermodynamically stable, the dissolution profile and the solid state properties of the product are maintained after storage at 40 °C, 75% RH for at least 90 days.
- 23 February 2011
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 8 (3) , 727-735
Improvement of the Dissolution Rate of Poorly Soluble Drugs by Solid Crystal Suspensions
We present a novel extrusion based approach where the dissolution rate of poorly soluble drugs (griseofulvin, phenytoin and spironolactone) is significantly accelerated. The drug and highly soluble mannitol are coprocessed in a hot melt extrusion operation. The obtained product is an intimate mixture of the crystalline drug and crystalline excipient, with up to 50% (w/w) drug load. The in vitro drug release from the obtained solid crystalline suspensions is over 2 orders of magnitude faster than that of the pure drug. Since the resulting product is crystalline, the accelerated dissolution rate does not bear the physical stability concerns inherent to amorphous formulations. This approach is useful in situations where the drug is not a good glass former or in cases where it is difficult to stabilize the amorphous drug. Being thermodynamically stable, the dissolution profile and the solid state properties of the product are maintained after storage at 40 °C, 75% RH for at least 90 days.