Sandeep Kumar Vashist
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sandeep Kumar Vashist has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Dan Zheng
NUSNNI-NanoCore, National University of Singapore, T-Lab Level 11, 5A Engineering Drive 1, 117580, Singapore
2 shared publications - Fwu-Shan Sheu
NUSNNI-NanoCore, National University of Singapore, T-Lab Level 11, 5A Engineering Drive 1, 117580, Singapore
2 shared publications - John H. T. Luong
School of Chemistry, University College Cork, T12 YN60 Cork, Ireland
2 shared publications BinBin Zhang
NUSNNI-NanoCore, National University of Singapore, T-Lab Level 11, 5A Engineering Drive 1, Singapore 117580, Singapore
1 shared publication- Edmond Lam
American Chemical Society
1 shared publication Khalid Al-Rubeaan
University Diabetes Center, King Saud University, P.O. Box 18397, Riyadh 11415, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
Graphene versus Multi-Walled Carbon Nanotubes for Electrochemical Glucose Biosensing
: A simple procedure was developed for the fabrication of electrochemical glucose biosensors using glucose oxidase (GOx), with graphene or multi-walled carbon nanotubes (MWCNTs). Graphene and MWCNTs were dispersed in 0.25% 3-aminopropyltriethoxysilane (APTES) and drop cast on 1% KOH-pre-treated glassy carbon electrodes (GCEs). The EDC (1-ethyl-(3-dimethylaminopropyl) carbodiimide)-activated GOx was then bound covalently on the graphene- or MWCNT-modified GCE. Both the graphene- and MWCNT-based biosensors detected the entire pathophysiological range of blood glucose in humans, 1.4–27.9 mM. However, the direct electron transfer (DET) between GOx and the modified GCE’s surface was only observed for the MWCNT-based biosensor. The MWCNT-based glucose biosensor also provided over a four-fold higher current signal than its graphene counterpart. Several interfering substances, including drug metabolites, provoked negligible interference at pathological levels for both the MWCNT- and graphene-based biosensors. However, the former was more prone to interfering substances and drug metabolites at extremely pathological concentrations than its graphene counterpart.
Open AccessGraphene versus Multi-Walled Carbon Nanotubes for Electrochemical Glucose Biosensing
: A simple procedure was developed for the fabrication of electrochemical glucose biosensors using glucose oxidase (GOx), with graphene or multi-walled carbon nanotubes (MWCNTs). Graphene and MWCNTs were dispersed in 0.25% 3-aminopropyltriethoxysilane (APTES) and drop cast on 1% KOH-pre-treated glassy carbon electrodes (GCEs). The EDC (1-ethyl-(3-dimethylaminopropyl) carbodiimide)-activated GOx was then bound covalently on the graphene- or MWCNT-modified GCE. Both the graphene- and MWCNT-based biosensors detected the entire pathophysiological range of blood glucose in humans, 1.4–27.9 mM. However, the direct electron transfer (DET) between GOx and the modified GCE’s surface was only observed for the MWCNT-based biosensor. The MWCNT-based glucose biosensor also provided over a four-fold higher current signal than its graphene counterpart. Several interfering substances, including drug metabolites, provoked negligible interference at pathological levels for both the MWCNT- and graphene-based biosensors. However, the former was more prone to interfering substances and drug metabolites at extremely pathological concentrations than its graphene counterpart.
- 1 October 2011
- Published by Elsevier in Analytical Biochemistry
- Vol. 417 (1) , 156-158
Sulfo-N-hydroxysuccinimide interferes with bicinchoninic acid protein assay
- 1 October 2011
- Published by Elsevier in Analytical Biochemistry
- Vol. 417 (1) , 156-158
Sulfo-N-hydroxysuccinimide interferes with bicinchoninic acid protein assay