Futao Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Futao Hu has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Ning Gan
School of Material Science and Chemical Engineering, Ningbo University, Ningbo, 315211, China; School of Public Health, Guangdong Pharmaceutical University, Guangzhou, 510006, China
12 shared publications - Yuting Cao
State Key Laboratory Base of Novel Functional Materials and Preparation Science, Faculty of Materials Science and Chemical Engineering, Ningbo University, Ningbo 315211, PR China
8 shared publications - Tianhua Li
The State Key Laboratory Base of Novel Functional Materials and Preparation Science, Faculty of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, China
7 shared publications Lei Zheng
2 shared publications- Qianli Jiang
Department of Hematology, Nanfang Hospital, Southern Medical University, Guangzhou 510515, China
2 shared publications Tianhua Li
Faculty of Material Science and Chemical Engineering of Ningbo University
2 shared publications
Latest Publications
- 27 April 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 181 (11-12) , 1341-1351
Magnetic nanospheres with a molecularly imprinted shell for the preconcentration of diethylstilbestrol
- 27 April 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 181 (11-12) , 1341-1351
Magnetic nanospheres with a molecularly imprinted shell for the preconcentration of diethylstilbestrol
- Open Access
An Ultrasensitive Electrochemiluminescent Immunoassay for Aflatoxin M1 in Milk, Based on Extraction by Magnetic Graphene and Detection by Antibody-Labeled CdTe Quantumn Dots-Carbon Nanotubes Nanocomposite
An ultrasensitive electrochemiluminescent immunoassay (ECLIA) for aflatoxins M1 (ATM1) in milk using magnetic Fe3O4-graphene oxides (Fe-GO) as the absorbent and antibody-labeled cadmium telluride quantum dots (CdTe QDs) as the signal tag is presented. Firstly, Fe3O4 nanoparticles were immobilized on GO to fabricate the magnetic nanocomposites, which were used as absorbent to ATM1. Secondly, aflatoxin M1 antibody (primary antibody, ATM1 Ab1), was attached to the surface of the CdTe QDs-carbon nanotubes nanocomposite to form the signal tag (ATM1 Ab1/CdTe-CNT). The above materials were characterized. The optimal experimental conditions were obtained. Thirdly, Fe-GO was employed for extraction of ATM1 in milk. Results indicated that it can adsorb ATM1 efficiently and selectively within a large extent of pH from 3.0 to 8.0. Adsorption processes reached 95% of the equilibrium within 10 min. Lastly, the ATM1 with a serial of concentrations absorbed on Fe-GO was conjugated with ATM1 Ab1/CdTe-CNT signal tag based on sandwich immunoassay. The immunocomplex can emit a strong ECL signal whose intensity depended linearly on the logarithm of ATM1 concentration from 1.0 to 1.0 × 105 pg/mL, with the detection limit (LOD) of 0.3 pg/mL (S/N = 3). The method was more sensitive for ATM1 detection compared to the ELISA method. Finally, ten samples of milk were tested based on the immunoassay. The method is fast and requires very little sample preparation, which was suitable for high-throughput screening of mycotoxins in food.
Open AccessAn Ultrasensitive Electrochemiluminescent Immunoassay for Aflatoxin M1 in Milk, Based on Extraction by Magnetic Graphene and Detection by Antibody-Labeled CdTe Quantumn Dots-Carbon Nanotubes Nanocomposite
An ultrasensitive electrochemiluminescent immunoassay (ECLIA) for aflatoxins M1 (ATM1) in milk using magnetic Fe3O4-graphene oxides (Fe-GO) as the absorbent and antibody-labeled cadmium telluride quantum dots (CdTe QDs) as the signal tag is presented. Firstly, Fe3O4 nanoparticles were immobilized on GO to fabricate the magnetic nanocomposites, which were used as absorbent to ATM1. Secondly, aflatoxin M1 antibody (primary antibody, ATM1 Ab1), was attached to the surface of the CdTe QDs-carbon nanotubes nanocomposite to form the signal tag (ATM1 Ab1/CdTe-CNT). The above materials were characterized. The optimal experimental conditions were obtained. Thirdly, Fe-GO was employed for extraction of ATM1 in milk. Results indicated that it can adsorb ATM1 efficiently and selectively within a large extent of pH from 3.0 to 8.0. Adsorption processes reached 95% of the equilibrium within 10 min. Lastly, the ATM1 with a serial of concentrations absorbed on Fe-GO was conjugated with ATM1 Ab1/CdTe-CNT signal tag based on sandwich immunoassay. The immunocomplex can emit a strong ECL signal whose intensity depended linearly on the logarithm of ATM1 concentration from 1.0 to 1.0 × 105 pg/mL, with the detection limit (LOD) of 0.3 pg/mL (S/N = 3). The method was more sensitive for ATM1 detection compared to the ELISA method. Finally, ten samples of milk were tested based on the immunoassay. The method is fast and requires very little sample preparation, which was suitable for high-throughput screening of mycotoxins in food.
- Open Access
An Ultrasensitive Electrochemical Immunosensor for HIV p24 Based on Fe3O4@SiO2 Nanomagnetic Probes and Nanogold Colloid-Labeled Enzyme–Antibody Copolymer as Signal Tag
An ultrasensitive portable electrochemical immunosensor for human immunodeficiency virus p24 (HIV p24) antigen detection has been developed, whereby the detection sensitivity was 1000 times higher than that of the ELISA method. Firstly, a novel HRP enzyme–antibody copolymer (EV-p24 Ab2) was synthesized through an EnVision regent (EV, a dextrin amine skeleton anchoring more than 100 molecules of HRP and 15 molecules of anti IgG), then incubated in the secondary antibody of p24. Secondly, the copolymer was immobilized on the gold nanocolloids (AuNPs) to fabricate a novel signal tag (AuNPs/EV-p24 Ab2). Subsequently, a sandwich-type immunoreaction would take place between the capture probe (silicon dioxide-coated magnetic Fe3O4 nanoparticles (MNPs) labeled with the primary p24 antibody (MNPs-p24 Ab1)), p24 (different concentrations) and the signal tag [AuNPs/EV-p24 Ab2)] to form the immunocomplex. Finally, the immunocomplex was absorbed on the surface of screen printed carbon electrode (SPCE) by a magnet and immersed in the o-hydroxyl phenol (HQ) and H2O2. The large amounts of HRP on the signal tag can catalyze the oxidation of HQ by H2O2, which can induce an amplified reductive current. Moreover, the capture probe could improve the accumulation ability of p24 and facilitate its separation from the substrate through the magnet. Under optimal conditions, the proposed immunoassay exhibited good sensitivity to p24 within a certain concentration range from 0.001 to 10.00 ng/mL, with a detection limit of 0.5 pg/mL (S/N = 3). The proposed method can be used for real-time and early detection of HIV-infected people.
Open AccessAn Ultrasensitive Electrochemical Immunosensor for HIV p24 Based on Fe3O4@SiO2 Nanomagnetic Probes and Nanogold Colloid-Labeled Enzyme–Antibody Copolymer as Signal Tag
An ultrasensitive portable electrochemical immunosensor for human immunodeficiency virus p24 (HIV p24) antigen detection has been developed, whereby the detection sensitivity was 1000 times higher than that of the ELISA method. Firstly, a novel HRP enzyme–antibody copolymer (EV-p24 Ab2) was synthesized through an EnVision regent (EV, a dextrin amine skeleton anchoring more than 100 molecules of HRP and 15 molecules of anti IgG), then incubated in the secondary antibody of p24. Secondly, the copolymer was immobilized on the gold nanocolloids (AuNPs) to fabricate a novel signal tag (AuNPs/EV-p24 Ab2). Subsequently, a sandwich-type immunoreaction would take place between the capture probe (silicon dioxide-coated magnetic Fe3O4 nanoparticles (MNPs) labeled with the primary p24 antibody (MNPs-p24 Ab1)), p24 (different concentrations) and the signal tag [AuNPs/EV-p24 Ab2)] to form the immunocomplex. Finally, the immunocomplex was absorbed on the surface of screen printed carbon electrode (SPCE) by a magnet and immersed in the o-hydroxyl phenol (HQ) and H2O2. The large amounts of HRP on the signal tag can catalyze the oxidation of HQ by H2O2, which can induce an amplified reductive current. Moreover, the capture probe could improve the accumulation ability of p24 and facilitate its separation from the substrate through the magnet. Under optimal conditions, the proposed immunoassay exhibited good sensitivity to p24 within a certain concentration range from 0.001 to 10.00 ng/mL, with a detection limit of 0.5 pg/mL (S/N = 3). The proposed method can be used for real-time and early detection of HIV-infected people.
- Open Access
An Ultrasensitive Electrochemical Immunosensor for Alpha-Fetoprotein Using an Envision Complex-Antibody Copolymer as a Sensitive Label
A novel strategy is presented for sensitive detection of alfa-fetoprotein (AFP), using a horseradish peroxidase (HRP)-functionalized Envision antibody complex (EVC) as the label. The Envision-AFP signal antibody copolymer (EVC-AFP Ab2) was composed of a dextran amine skeleton anchoring more than 100 molecules of HRP and 15 molecules of secondary antibody, and acted as a signal tag in the immunosensor. The sensor was constructed using the following steps: First, gold electrode (GE) was modified with nano-gold (AuNPs) by electro-deposition in HAuCl4 solution. The high affinity of the AuNPs surface facilitates direct formation of a self-assembled thiolated protein G layer. Next, the coated GE was incubated in a solution of AFP capture antibody (AFP Ab1); these antibodies attach to the thiolated protein G layer through their non-antigenic regions, leaving the antigen binding sites for binding of target analyte. Following a sandwich immunoreaction, an EVC-AFP Ab2-AFP-AFP Ab1 immunocomplex was formed on the electrode surface, allowing large amounts of HRP on the complex to produce an amplified electrocatalytic current of hydroquinone (HQ) in the presence of hydrogen peroxide (H2O2). Highly amplified detection was achieved, with a detection limit of 2 pg/mL and a linear range of 0.005–0.2 ng/mL for AFP in 10 μL undiluted serum; this is near or below the normal levels of most cancer biomarker proteins in human serum. Measurements of AFP in the serum of cancer patients correlated strongly with standard enzyme-linked immunosorbent assays. These easily fabricated EVC-modified immunosensors show excellent promise for future fabrication of bioelectronic arrays. By varying the target biomolecules, this technique may be easily extended for use with other immunoassays, and thus represents a versatile design route.
Open AccessAn Ultrasensitive Electrochemical Immunosensor for Alpha-Fetoprotein Using an Envision Complex-Antibody Copolymer as a Sensitive Label
A novel strategy is presented for sensitive detection of alfa-fetoprotein (AFP), using a horseradish peroxidase (HRP)-functionalized Envision antibody complex (EVC) as the label. The Envision-AFP signal antibody copolymer (EVC-AFP Ab2) was composed of a dextran amine skeleton anchoring more than 100 molecules of HRP and 15 molecules of secondary antibody, and acted as a signal tag in the immunosensor. The sensor was constructed using the following steps: First, gold electrode (GE) was modified with nano-gold (AuNPs) by electro-deposition in HAuCl4 solution. The high affinity of the AuNPs surface facilitates direct formation of a self-assembled thiolated protein G layer. Next, the coated GE was incubated in a solution of AFP capture antibody (AFP Ab1); these antibodies attach to the thiolated protein G layer through their non-antigenic regions, leaving the antigen binding sites for binding of target analyte. Following a sandwich immunoreaction, an EVC-AFP Ab2-AFP-AFP Ab1 immunocomplex was formed on the electrode surface, allowing large amounts of HRP on the complex to produce an amplified electrocatalytic current of hydroquinone (HQ) in the presence of hydrogen peroxide (H2O2). Highly amplified detection was achieved, with a detection limit of 2 pg/mL and a linear range of 0.005–0.2 ng/mL for AFP in 10 μL undiluted serum; this is near or below the normal levels of most cancer biomarker proteins in human serum. Measurements of AFP in the serum of cancer patients correlated strongly with standard enzyme-linked immunosorbent assays. These easily fabricated EVC-modified immunosensors show excellent promise for future fabrication of bioelectronic arrays. By varying the target biomolecules, this technique may be easily extended for use with other immunoassays, and thus represents a versatile design route.
- 1 March 2012
- Published by American Scientific Publishers in Sensor Letters
- Vol. 10 (3) , 886-893
Signal Amplification of Electrochemical ELISA for the Detection of Alpha-Fetoprotein Using Core–Shell Fe3O4@Au Nanoparticles as Labels
A novel electrochemical enzyme-linked immunosorbent assay (ELISA) system of o-phenylenediamine (OPD)-H2O2-horseradish peroxidase (HRP) for sensitive detection of alpha-fetoprotein (AFP) was designed using magnetic core–shell Fe3O4@Au nanoparticles as labels. The detection antibodies were prepared by immobilization of HRP-anti-AFP and HRP onto the surface of Fe3O4@Au nanoparticles (Fe3O4@Au-HRP-anti-AFP). After the sandwich-type immunoreaction on polystyrene 96-well microtiter plate, the formed HRP-labeled immunoconjugate showed good enzymatic activity for the oxidation of OPD by H2O2. Enhanced detection sensitivity was achieved where the large surface area of Fe3O4@Au nanoparticles carriers increased the amount of HRP on per sandwich-type immunoreaction. The approach provided a linear response range between 0.01 and 200 ng·mL−1 with a detection limit of 5 pg·mL−1 The proposed electrochemical ELISA method exhibited good precision, high sensitivity and acceptable reproducibility, and could be further developed for clinical detections of AFP and other biomarkers.
- 1 March 2012
- Published by American Scientific Publishers in Sensor Letters
- Vol. 10 (3) , 886-893
Signal Amplification of Electrochemical ELISA for the Detection of Alpha-Fetoprotein Using Core–Shell Fe3O4@Au Nanoparticles as Labels
A novel electrochemical enzyme-linked immunosorbent assay (ELISA) system of o-phenylenediamine (OPD)-H2O2-horseradish peroxidase (HRP) for sensitive detection of alpha-fetoprotein (AFP) was designed using magnetic core–shell Fe3O4@Au nanoparticles as labels. The detection antibodies were prepared by immobilization of HRP-anti-AFP and HRP onto the surface of Fe3O4@Au nanoparticles (Fe3O4@Au-HRP-anti-AFP). After the sandwich-type immunoreaction on polystyrene 96-well microtiter plate, the formed HRP-labeled immunoconjugate showed good enzymatic activity for the oxidation of OPD by H2O2. Enhanced detection sensitivity was achieved where the large surface area of Fe3O4@Au nanoparticles carriers increased the amount of HRP on per sandwich-type immunoreaction. The approach provided a linear response range between 0.01 and 200 ng·mL−1 with a detection limit of 5 pg·mL−1 The proposed electrochemical ELISA method exhibited good precision, high sensitivity and acceptable reproducibility, and could be further developed for clinical detections of AFP and other biomarkers.
- 30 November 2011
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 39 (11) , 1634-1640
A Sandwich-type Amperometric Immunosensor Based on One-dimensional Assembly of Magnetic DNA Nanoprobes
- 30 November 2011
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 39 (11) , 1634-1640
A Sandwich-type Amperometric Immunosensor Based on One-dimensional Assembly of Magnetic DNA Nanoprobes
- 20 November 2011
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Analytical Chemistry
- Vol. 39 (11) , 1634-1640
A Sandwich Amperometric Immunosensor Based on One-dimensional Assembly of Magnetic DNA Nano-probe
- 20 November 2011
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Analytical Chemistry
- Vol. 39 (11) , 1634-1640
A Sandwich Amperometric Immunosensor Based on One-dimensional Assembly of Magnetic DNA Nano-probe