Latest Publications

  • Physics

    by Teiji Nishio

  • Open Access

    Design, development of water tank-type lung phantom and dosimetric verification in institutions participating in a phase I study of stereotactic body radiation therapy in patients with T2N0M0 non-small cell lung cancer: Japan Clinical Oncology Group trial (JCOG0702)

    by T. Nishio, H. Shirato, M. Ishikawa, Y. Miyabe, S. Kito, Y. Narita, R. Onimaru, S. Ishikura, Y. Ito, M. Hiraoka

    A domestic multicenter phase I study of stereotactic body radiotherapy (SBRT) for T2N0M0 non-small cell lung cancer in inoperable patients or elderly patients who refused surgery was initiated as the Japan Clinical Oncology Group trial (JCOG0702) in Japan. Prior to the clinical study, the accuracy of dose calculation in radiation treatment-planning systems was surveyed in participating institutions, and differences in the irradiating dose between the institutions were investigated. We developed a water tank-type lung phantom appropriate for verification of the exposure dose in lung SBRT. Using this water tank-type lung phantom, the dose calculated in the radiation treatment-planning system and the measured dose using a free air ionization chamber and dosimetric film were compared in a visiting survey of the seven institutions participating in the clinical study. In all participating institutions, differences between the calculated and the measured dose in the irradiation plan were as follows: the accuracy of the absolute dose in the center of the simulated tumor measured using a free air ionization chamber was within 2%, the mean gamma value was ≤ 0.47 on gamma analysis following the local dose criteria, and the pass rate was >87% for 3%/3 mm from measurement of dose distribution with dosimetric film. These findings confirmed the accuracy of delivery doses in the institutions participating in the clinical study, so that a study with integration of the institutions could be initiated.


  • Proton Beam Therapy as a Nonsurgical Approach to Mucosal Melanoma of the Head and Neck: A Pilot Study

    by Sadamoto Zenda, Mitsuhiko Kawashima, Teiji Nishio, Ryosuke Kohno, Keiji Nihei, Masakatsu Onozawa, Satoko Arahira, Takashi Ogino


  • Pencil Beam Scanning System Based On A Cyclotron

    by Toshiki Tachikawa, Hideki Nonaka, Yukio Kumata, Teiji Nishio, Takashi Ogino, Floyd D. McDaniel, Barney L. Doyle

    Sumitomo Heavy Industries, Ltd. (SHI) has developed a new pencil beam scanning system (PBS) for proton therapy in collaboration with National Cancer Center Hospital East (NCCHE). Taking advantage of the continuous beam from the cyclotron P235, the line scanning method is employed in order to realize continuous irradiation with high dose rate. 3D uniform and sphere field was irradiated and compared with the simulation.


  • Top Cited Papers

    The Development and Clinical Use of a Beam ON-LINE PET System Mounted on a Rotating Gantry Port in Proton Therapy

    by Teiji Nishio, Aya Miyatake, Takashi Ogino, Keiichi Nakagawa, Nagahiro Saijo, Hiroyasu Esumi


    • 1 January 2009
      • Vol. 28  (4) , 172-206

    Research on radiation protection in the application of new technologies for proton and heavy ion radiotherapy.

    by Hirohiko Tujii, Takashi Akagi, Keiichi Akahane, Yoshitomo Uwamino, Tatsuya Ono, Tatsuaki Kanai, Ryosuke Kohno, Takeji Sakae, Masakazu Shimizu, Eriko Urakabe, et al.

    Particle radiotherapy using proton and heavy ion beams has shown improved clinical results and is a promising cancer therapy which is expected to gradually spread in Japan. There are, however, no special regulations for radiotherapy treatment facilities. They have been operated under the same safety regulations as for a research facility using a research accelerator. Significantly high-energy radiation is necessary for particle radiotherapy compared with conventional radiation therapy. The treatment facility, therefore, should have a large accelerator, which is installed in a room with a thick shield wall. Data on radiation protection for such high energy medical facilities is fragmentary and insufficient. In this study, we examined the necessity of other regulations for the safe operation of medical facilities for particle radiotherapy. First, we measured activation levels of the therapeutic devices and of patients. Next the safety level of the medical facility was evaluated from the viewpoint of radiation protection. We have confirmed the facilities can be safely operated by present regulations given in the Law Concerning Prevention from Radiation Hazards due to Radiation Isotopes, etc. or the Law for Health Protection and Medical Care.


    • 1 January 2008
      • Vol. 28  (1) , 26-32

    [Improvement of dose monitor system in rotational gantry for proton therapy at national cancer center hospital East].

    by Tomoko Miyagishi-Gomi, Teiji Nishio, Ryosuke Kohno, Satoru Kameoka, Kazutomo Matsumura, Naoya Uzawa, Hideki Saito, Toshinobu Sasano, Ryuichi Oota, Takashi Ogino

    Quality assurance and quality control of delivered dose are important in proton therapy. The delivered proton dose is controlled using a dose monitor system which consists of two ionization chambers filled with free air. Response of the monitor for the delivered dose changes under the influence of temperature and pressure of surrounding air. In the dose monitor system at the National Cancer Center Hospital East, the monitor is near an X-tray tube which operates at a high temperature and is frequently used in every patient setup. Therefore the response of the dose monitor changes a lot with the temperature of the X-ray tube. In this report, temperature and pressure influence on the dose monitor was investigated in detail. Furthermore, a new method was presented to correct the monitor response using the real-time data of temperature and pressure at any time for each patient. This method improved the accuracy of delivered dose from 1% to 0.5%.

  • Experimental verification of the utility of positron emitter nuclei generated by photonuclear reactions for X-ray beam monitoring in a phantom

    by Teiji Nishio, Taku Inaniwa, Kazumasa Inoue, Aya Miyatake, Keiichi Nakagawa, Kiyoshi Yoda, Takashi Ogino

    The utility of positron emitter nuclei generated by photonuclear reactions was verified for X-ray beam monitoring in a phantom. Positron emission tomography-computed tomography (PET-CT) images of a gelatinous water phantom (H2O target) and a polyethylene phantom (CH2 target) were acquired 5 min after delivering a dose of 17 Gy with an X-ray beam energy of 21 MV. Reconstructed PET images and the calculated half-life showed that the positron emitters of 15O (half-life 122.2 s) in the H2O target and 11C (half-life 20.4 min) in the CH2 target were generated by photonuclear reactions. A comparison was made between measured activity and dose distributions for each target. The measured times of annihilation gamma rays from the positron emitter nucleus were 10 and 30 min for the 15O nucleus in the H2O target and the 11C nucleus in the CH2 target, respectively. The activity distributions of the 15O and 11C positron emitter nuclei were similar to the measured dose distributions for both depth and lateral directions except for dose buildup and collimator edge regions. It was confirmed that no activity was detected at an X-ray energy of 14 MV, which was far below the energy threshold for both photonuclear reactions. It was estimated that the PET-CT image acquired from the activity of the 15O and 11C positron emitter nuclei might provide the area of X-ray beam irradiation in a phantom.


  • Experimental verification of proton beam monitoring in a human body by use of activity image of positron-emitting nuclei generated by nuclear fragmentation reaction

    by Teiji Nishio, Aya Miyatake, Kazumasa Inoue, Tomoko Gomi-Miyagishi, Ryosuke Kohno, Satoru Kameoka, Keiichi Nakagawa, Takashi Ogino

    Proton therapy is a form of radiotherapy that enables concentration of dose on a tumor by use of a scanned or modulated Bragg peak. Therefore, it is very important to evaluate the proton-irradiated volume accurately. The proton-irradiated volume can be confirmed by detection of pair-annihilation gamma rays from positron-emitting nuclei generated by the nuclear fragmentation reaction of the incident protons on target nuclei using a PET apparatus. The activity of the positron-emitting nuclei generated in a patient was measured with a PET-CT apparatus after proton beam irradiation of the patient. Activity measurement was performed in patients with tumors of the brain, head and neck, liver, lungs, and sacrum. The 3-D PET image obtained on the CT image showed the visual correspondence with the irradiation area of the proton beam. Moreover, it was confirmed that there were differences in the strength of activity from the PET-CT images obtained at each irradiation site. The values of activity obtained from both measurement and calculation based on the reaction cross section were compared, and it was confirmed that the intensity and the distribution of the activity changed with the start time of the PET imaging after proton beam irradiation. The clinical use of this information about the positron-emitting nuclei will be important for promoting proton treatment with higher accuracy in the future.


  • Dose‐volume delivery guided proton therapy using beam on‐line PET system

    by Teiji Nishio, Takashi Ogino, Kazuhiro Nomura, Hiroshi Uchida

    Proton therapy is one form of radiotherapy in which the irradiation can be concentrated on a tumor using a scanned or modulated Bragg peak. Therefore, it is very important to evaluate the proton‐irradiated volume accurately. The proton‐irradiated volume can be confirmed by detection of pair annihilation gamma rays from positron emitter nuclei generated by the target nuclear fragment reaction of irradiated proton nuclei and nuclei in the irradiation target using a positron emission tomography (PET) apparatus, and dose‐volume delivery guided proton therapy (DGPT) can thereby be achieved using PET images. In the proton treatment room, a beam ON‐LINE PET system (BOLPs) was constructed so that a PET apparatus of the planar‐type with a high spatial resolution of about was mounted with the field of view covering the isocenter of the beam irradiation system. The position and intensity of activity were measured using the BOLPs immediately after the proton irradiation of a gelatinous water target containing nuclei at different proton irradiation energy levels. The change of the activity‐distribution range against the change of the physical range was observed within . The experiments of proton irradiation to a rabbit and the imaging of the activity were performed. In addition, the proton beam energy used to irradiate the rabbit was changed. When the beam condition was changed, the difference between the two images acquired from the measurement of the BOLPs was confirmed to clearly identify the proton‐irradiated volume.