Indumathi Vedarethinam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Indumathi Vedarethinam has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Maria Dimaki
Department of Micro- and Nanotechnology, Technical University of Denmark, Kgs. Lyngby, Denmark
4 shared publications - Winnie Edith Svendsen
Technical University of Denmark
4 shared publications - Pranjul Shah
DTU-Nanotech, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark
3 shared publications - Dorota Kwasny
Department of Micro- and Nanotechnology, Technical University of Denmark, rsteds Plads, Building 345 B, 2800 Kgs. Lyngby, Denmark
2 shared publications - Luigi Sasso
Dept. of Precision and Microsystems Engineering, Delft University of Technology, 2628CD Delft (The Netherlands)
2 shared publications - Patricia Vazquez
Department of Micro- and Nanotechnology, Technical University of Denmark, Ørsteds Plads 345ø, 2800 Kgs. Lyngby, Denmark
2 shared publications
Latest Publications
- Open Access
- 2 March 2012
- Published by IntechOpen
Microtechnologies Enable Cytogenetics
Microtechnologies Enable Cytogenetics | InTechOpen, Published on: 2012-03-02. Authors: Dorota Kwasny, Indumathi Vedarethinam, Pranjul Shah, et
- 2 March 2012
- Published by IntechOpen
Open AccessMicrotechnologies Enable Cytogenetics
Microtechnologies Enable Cytogenetics | InTechOpen, Published on: 2012-03-02. Authors: Dorota Kwasny, Indumathi Vedarethinam, Pranjul Shah, et
- Open Access
- 4 April 2011
- Published by MDPI AG in Micromachines
- Vol. 2 (2) , 116-128
FISHprep: A Novel Integrated Device for Metaphase FISH Sample Preparation
We present a novel integrated device for preparing metaphase chromosomes spread slides (FISHprep). The quality of cytogenetic analysis from patient samples greatly relies on the efficiency of sample pre-treatment and/or slide preparation. In cytogenetic slide preparation, cell cultures are routinely used to process samples (for culture, arrest and fixation of cells) and/or to expand limited amount of samples (in case of prenatal diagnostics). Arguably, this expansion and other sample pretreatments form the longest part of the entire diagnostic protocols spanning over 3–4 days. We present here a novel device with an integrated expansion chamber to culture, arrest and fix metaphase cells followed by a subsequent splashing protocol leading to ample metaphase chromosome spreads on a glass slide for metaphase FISH analysis. The device provides an easy, disposable, low cost, integrated solution with minimal handling for metaphase FISH slide preparation.
- 4 April 2011
- Published by MDPI AG in Micromachines
- Vol. 2 (2) , 116-128
Open AccessFISHprep: A Novel Integrated Device for Metaphase FISH Sample Preparation
We present a novel integrated device for preparing metaphase chromosomes spread slides (FISHprep). The quality of cytogenetic analysis from patient samples greatly relies on the efficiency of sample pre-treatment and/or slide preparation. In cytogenetic slide preparation, cell cultures are routinely used to process samples (for culture, arrest and fixation of cells) and/or to expand limited amount of samples (in case of prenatal diagnostics). Arguably, this expansion and other sample pretreatments form the longest part of the entire diagnostic protocols spanning over 3–4 days. We present here a novel device with an integrated expansion chamber to culture, arrest and fix metaphase cells followed by a subsequent splashing protocol leading to ample metaphase chromosome spreads on a glass slide for metaphase FISH analysis. The device provides an easy, disposable, low cost, integrated solution with minimal handling for metaphase FISH slide preparation.
- Open Access
Conducting Polymer 3D Microelectrodes
Conducting polymer 3D microelectrodes have been fabricated for possible future neurological applications. A combination of micro-fabrication techniques and chemical polymerization methods has been used to create pillar electrodes in polyaniline and polypyrrole. The thin polymer films obtained showed uniformity and good adhesion to both horizontal and vertical surfaces. Electrodes in combination with metal/conducting polymer materials have been characterized by cyclic voltammetry and the presence of the conducting polymer film has shown to increase the electrochemical activity when compared with electrodes coated with only metal. An electrochemical characterization of gold/polypyrrole electrodes showed exceptional electrochemical behavior and activity. PC12 cells were finally cultured on the investigated materials as a preliminary biocompatibility assessment. These results show that the described electrodes are possibly suitable for future in-vitro neurological measurements.
Open AccessConducting Polymer 3D Microelectrodes
Conducting polymer 3D microelectrodes have been fabricated for possible future neurological applications. A combination of micro-fabrication techniques and chemical polymerization methods has been used to create pillar electrodes in polyaniline and polypyrrole. The thin polymer films obtained showed uniformity and good adhesion to both horizontal and vertical surfaces. Electrodes in combination with metal/conducting polymer materials have been characterized by cyclic voltammetry and the presence of the conducting polymer film has shown to increase the electrochemical activity when compared with electrodes coated with only metal. An electrochemical characterization of gold/polypyrrole electrodes showed exceptional electrochemical behavior and activity. PC12 cells were finally cultured on the investigated materials as a preliminary biocompatibility assessment. These results show that the described electrodes are possibly suitable for future in-vitro neurological measurements.
- Open Access
Fabrication and Characterization of 3D Micro- and Nanoelectrodes for Neuron Recordings
In this paper we discuss the fabrication and characterization of three dimensional (3D) micro- and nanoelectrodes with the goal of using them for extra- and intracellular studies. Two different types of electrodes will be described: high aspect ratio microelectrodes for studying the communication between cells and ultimately for brain slice recordings and small nanoelectrodes for highly localized measurements and ultimately for intracellular studies. Electrical and electrochemical characterization of these electrodes as well as the results of PC12 cell differentiation on chip will be presented and discussed.
Open AccessFabrication and Characterization of 3D Micro- and Nanoelectrodes for Neuron Recordings
In this paper we discuss the fabrication and characterization of three dimensional (3D) micro- and nanoelectrodes with the goal of using them for extra- and intracellular studies. Two different types of electrodes will be described: high aspect ratio microelectrodes for studying the communication between cells and ultimately for brain slice recordings and small nanoelectrodes for highly localized measurements and ultimately for intracellular studies. Electrical and electrochemical characterization of these electrodes as well as the results of PC12 cell differentiation on chip will be presented and discussed.
- Open Access
Metaphase FISH on a Chip: Miniaturized Microfluidic Device for Fluorescence in situ Hybridization
Fluorescence in situ Hybridization (FISH) is a major cytogenetic technique for clinical genetic diagnosis of both inherited and acquired chromosomal abnormalities. Although FISH techniques have evolved and are often used together with other cytogenetic methods like CGH, PRINS and PNA-FISH, the process continues to be a manual, labour intensive, expensive and time consuming technique, often taking over 3–5 days, even in dedicated labs. We have developed a novel microFISH device to perform metaphase FISH on a chip which overcomes many shortcomings of the current laboratory protocols. This work also introduces a novel splashing device for preparing metaphase spreads on a microscope glass slide, followed by a rapid adhesive tape-based bonding protocol leading to rapid fabrication of the microFISH device. The microFISH device allows for an optimized metaphase FISH protocol on a chip with over a 20-fold reduction in the reagent volume. This is the first demonstration of metaphase FISH on a microfluidic device and offers a possibility of automation and significant cost reduction of many routine diagnostic tests of genetic anomalies.
Open AccessMetaphase FISH on a Chip: Miniaturized Microfluidic Device for Fluorescence in situ Hybridization
Fluorescence in situ Hybridization (FISH) is a major cytogenetic technique for clinical genetic diagnosis of both inherited and acquired chromosomal abnormalities. Although FISH techniques have evolved and are often used together with other cytogenetic methods like CGH, PRINS and PNA-FISH, the process continues to be a manual, labour intensive, expensive and time consuming technique, often taking over 3–5 days, even in dedicated labs. We have developed a novel microFISH device to perform metaphase FISH on a chip which overcomes many shortcomings of the current laboratory protocols. This work also introduces a novel splashing device for preparing metaphase spreads on a microscope glass slide, followed by a rapid adhesive tape-based bonding protocol leading to rapid fabrication of the microFISH device. The microFISH device allows for an optimized metaphase FISH protocol on a chip with over a 20-fold reduction in the reagent volume. This is the first demonstration of metaphase FISH on a microfluidic device and offers a possibility of automation and significant cost reduction of many routine diagnostic tests of genetic anomalies.