Hannes Sturm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hannes Sturm has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Walter Lang
Institute for Microsensors, Actuators and Systems, Universität Bremen, 28359 Bremen, Germany
3 shared publications - Dieter Westermann
Deutsche Wind Guard Wind Tunnel Services GmbH, Oldenburger Straße 65, 26316 Varel, Germany
1 shared publication - Gerrit Dumstorff
Institute for Microsensors, -actuators and -systems (IMSAS), Microsystems Center Bremen (MCB), University of Bremen, 28359 Bremen, Germany
1 shared publication - Peter Busche
Deutsche Wind Guard Wind Tunnel Services GmbH, Oldenburger Straße 65, 26316 Varel, Germany
1 shared publication - Safir Issa
IMSAS (Institute for Microsensors, Actuators and Systems), Microsystems Center Bremen (MCB), University of Bremen, Otto-Hahn-Allee, Bld. NW1, Bremen D-28359, Germany
1 shared publication
Latest Publications
- Open Access
Boundary Layer Separation and Reattachment Detection on Airfoils by Thermal Flow Sensors
A sensor concept for detection of boundary layer separation (flow separation, stall) and reattachment on airfoils is introduced in this paper. Boundary layer separation and reattachment are phenomena of fluid mechanics showing characteristics of extinction and even inversion of the flow velocity on an overflowed surface. The flow sensor used in this work is able to measure the flow velocity in terms of direction and quantity at the sensor’s position and expected to determine those specific flow conditions. Therefore, an array of thermal flow sensors has been integrated (flush-mounted) on an airfoil and placed in a wind tunnel for measurement. Sensor signals have been recorded at different wind speeds and angles of attack for different positions on the airfoil. The sensors used here are based on the change of temperature distribution on a membrane (calorimetric principle). Thermopiles are used as temperature sensors in this approach offering a baseline free sensor signal, which is favorable for measurements at zero flow. Measurement results show clear separation points (zero flow) and even negative flow values (back flow) for all sensor positions. In addition to standard silicon-based flow sensors, a polymer-based flexible approach has been tested showing similar results.
Open AccessBoundary Layer Separation and Reattachment Detection on Airfoils by Thermal Flow Sensors
A sensor concept for detection of boundary layer separation (flow separation, stall) and reattachment on airfoils is introduced in this paper. Boundary layer separation and reattachment are phenomena of fluid mechanics showing characteristics of extinction and even inversion of the flow velocity on an overflowed surface. The flow sensor used in this work is able to measure the flow velocity in terms of direction and quantity at the sensor’s position and expected to determine those specific flow conditions. Therefore, an array of thermal flow sensors has been integrated (flush-mounted) on an airfoil and placed in a wind tunnel for measurement. Sensor signals have been recorded at different wind speeds and angles of attack for different positions on the airfoil. The sensors used here are based on the change of temperature distribution on a membrane (calorimetric principle). Thermopiles are used as temperature sensors in this approach offering a baseline free sensor signal, which is favorable for measurements at zero flow. Measurement results show clear separation points (zero flow) and even negative flow values (back flow) for all sensor positions. In addition to standard silicon-based flow sensors, a polymer-based flexible approach has been tested showing similar results.
- Open Access
- 21 October 2011
- Published by MDPI AG in Micromachines
- Vol. 2 (4) , 385-393
Modeling of the Response Time of Thermal Flow Sensors
This paper introduces a simple theoretical model for the response time of thermal flow sensors. Response time is defined here as the time needed by the sensor output signal to reach 63.2% of amplitude due to a change of fluid flow. This model uses the finite-difference method to solve the heat transfer equations, taking into consideration the transient conduction and convection between the sensor membrane and the surrounding fluid. Program results agree with experimental measurements and explain the response time dependence on the velocity and the sensor geometry. Values of the response time vary from about 5 ms in the case of stagnant flow to 1.5 ms for a flow velocity of 44 m/s.
- 21 October 2011
- Published by MDPI AG in Micromachines
- Vol. 2 (4) , 385-393
Open AccessModeling of the Response Time of Thermal Flow Sensors
This paper introduces a simple theoretical model for the response time of thermal flow sensors. Response time is defined here as the time needed by the sensor output signal to reach 63.2% of amplitude due to a change of fluid flow. This model uses the finite-difference method to solve the heat transfer equations, taking into consideration the transient conduction and convection between the sensor membrane and the surrounding fluid. Program results agree with experimental measurements and explain the response time dependence on the velocity and the sensor geometry. Values of the response time vary from about 5 ms in the case of stagnant flow to 1.5 ms for a flow velocity of 44 m/s.