Eric D. Salin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eric D. Salin has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Erin J. Templeton
Department of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec, Canada H3A 0B8
3 shared publications- Josiane P. Lafleur
Invisible-Light Labs GmbH, Taubstummengasse 11, 1040 Vienna, Austria
3 shared publications Rebecca Lam
Department of Chemistry, McGill University, 801 Sherbrooke St. W., Montreal, Quebec, Canada
3 shared publicationsAlexei Kazarine
Department of Chemistry, McGill University, 801 Sherbrooke Street West, Montreal, Quebec, Canada H3A 0B8
2 shared publicationsHing Man Chan
Centre for Indigenous Peoples’ Nutrition and Environment (CINE) and School of Dietetics and Human Nutrition, McGill University, 21111 Lakeshore Road, Ste. Anne de Bellevue, Quebec, Canada
2 shared publications- Matthew C. R. Kong
McGill University
2 shared publications
Latest Publications
- 26 June 2014
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 14 (18) , 3572-3581
Volumetric measurements by image segmentation on centrifugal microfluidic platforms in motion
An image segmentation based method was developed to perform volumetric measurements of liquid aliquots in centrifugal microfluidic platforms in motion. The method was designed to be as automated as possible to allow its applicability to the large variety of available design features that tend to be included on such platforms. Experiments have indicated a relative standard deviation (RSD) of 0.3% for replicate measurements and 1% for same volume aliquots injected into different sized chambers. The versatility of the method in regards to chamber shape and size, liquid colour and platform rotational frequency was demonstrated. This flexibility should allow it to be used for a variety of applications including real time metering of volumes in platforms, quantitative monitoring of a design's performance in real time and could result in the elimination of metering chambers for some applications.
- 26 June 2014
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 14 (18) , 3572-3581
Volumetric measurements by image segmentation on centrifugal microfluidic platforms in motion
An image segmentation based method was developed to perform volumetric measurements of liquid aliquots in centrifugal microfluidic platforms in motion. The method was designed to be as automated as possible to allow its applicability to the large variety of available design features that tend to be included on such platforms. Experiments have indicated a relative standard deviation (RSD) of 0.3% for replicate measurements and 1% for same volume aliquots injected into different sized chambers. The versatility of the method in regards to chamber shape and size, liquid colour and platform rotational frequency was demonstrated. This flexibility should allow it to be used for a variety of applications including real time metering of volumes in platforms, quantitative monitoring of a design's performance in real time and could result in the elimination of metering chambers for some applications.
- 24 November 2013
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 17 (1) , 245-251
A novel filtration method integrated on centrifugal microfluidic devices
- 24 November 2013
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 17 (1) , 245-251
A novel filtration method integrated on centrifugal microfluidic devices
- 24 April 2012
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 13 (3) , 519-525
Micromixing by pneumatic agitation on continually rotating centrifugal microfluidic platforms
- 24 April 2012
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 13 (3) , 519-525
Micromixing by pneumatic agitation on continually rotating centrifugal microfluidic platforms
- Open Access
- 22 December 2011
- Published by MDPI AG in Micromachines
- Vol. 3 (1) , 1-9
Displacement Pumping of Liquids Radially Inward on Centrifugal Microfluidic Platforms in Motion
We describe two novel centrifugal microfluidic platform designs that enable passive pumping of liquids radially inward while the platform is in motion. The first design uses an immiscible liquid to displace an aqueous solution back towards the center of the platform, while the second design uses an arbitrary pumping liquid with a volume of air between it and the solution being pumped. Both designs demonstrated the ability to effectively pump 55% to 60% of the solution radially inward at rotational frequencies as low as 400 rpm (6.7 Hz) to 700 rpm (11.7 Hz). The pumping operations reached completion within 120 s and 400 s respectively. These platform designs for passive pumping of liquids do not require moving parts or complex fabrication techniques. They offer great potential for increasing the number of sequential operations that can be performed on centrifugal microfluidic platforms, thereby reducing a fundamental limitation often associated with these platforms.
- 22 December 2011
- Published by MDPI AG in Micromachines
- Vol. 3 (1) , 1-9
Open AccessDisplacement Pumping of Liquids Radially Inward on Centrifugal Microfluidic Platforms in Motion
We describe two novel centrifugal microfluidic platform designs that enable passive pumping of liquids radially inward while the platform is in motion. The first design uses an immiscible liquid to displace an aqueous solution back towards the center of the platform, while the second design uses an arbitrary pumping liquid with a volume of air between it and the solution being pumped. Both designs demonstrated the ability to effectively pump 55% to 60% of the solution radially inward at rotational frequencies as low as 400 rpm (6.7 Hz) to 700 rpm (11.7 Hz). The pumping operations reached completion within 120 s and 400 s respectively. These platform designs for passive pumping of liquids do not require moving parts or complex fabrication techniques. They offer great potential for increasing the number of sequential operations that can be performed on centrifugal microfluidic platforms, thereby reducing a fundamental limitation often associated with these platforms.
- 4 November 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (23) , 9186-9190
A Valveless Pneumatic Fluid Transfer Technique Applied To Standard Additions on a Centrifugal Microfluidic Platform
This paper demonstrates a valveless pneumatic fluid transfer technique applicable to centrifugal microfluidic platforms. The technique involves using compressed gas to generate a pneumatic force, which works together with the centrifugal force to control and direct fluid flow. Fluid can be pneumatically transferred from chamber to chamber, greatly decreasing the number of conventional valves required in a multistep process. By varying the rotational frequency of the centrifugal microfluidic platform while pneumatic force is applied, sequential fluid transfer steps can be achieved. The effectiveness of this fluid transfer method is demonstrated by performing a standard additions calibration. This technique is shown to be robust, easy to implement, and greatly reduces the design limitations traditionally associated with centrifugal microfluidic platforms.
- 4 November 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (23) , 9186-9190
A Valveless Pneumatic Fluid Transfer Technique Applied To Standard Additions on a Centrifugal Microfluidic Platform
This paper demonstrates a valveless pneumatic fluid transfer technique applicable to centrifugal microfluidic platforms. The technique involves using compressed gas to generate a pneumatic force, which works together with the centrifugal force to control and direct fluid flow. Fluid can be pneumatically transferred from chamber to chamber, greatly decreasing the number of conventional valves required in a multistep process. By varying the rotational frequency of the centrifugal microfluidic platform while pneumatic force is applied, sequential fluid transfer steps can be achieved. The effectiveness of this fluid transfer method is demonstrated by performing a standard additions calibration. This technique is shown to be robust, easy to implement, and greatly reduces the design limitations traditionally associated with centrifugal microfluidic platforms.
- 1 October 2009
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 24 (11) , 1511-1516
Pre-concentration of trace metals on centrifugal microfluidic discs with direct determination by laser ablation inductively coupled plasma mass spectrometry
Solid Phase Extraction (SPE) is commonly used for pre-concentration and matrix removal in trace metal determinations. We present a novel centrifugal microfluidic device for field sampling and on-site pre-concentration of water samples. Metal-8-hydroxyquinoline complexes are adsorbed onto miniature C18-bonded silica gel columns on centrifugal microfluidic discs. Laser Ablation (LA) is used to directly vaporize the analytes from the column, instead of eluting the pre-concentrated analytes for introduction in an Inductively Coupled Plasma Mass Spectrometer (ICP-MS) by conventional solution nebulization. Absolute detection limits ranging between 0.1 and 12 ng were obtained for Ni, Cu, V, Pb and Co in drinking water Certified Reference Materials (CRMs). These centrifugal devices require only 1–600 µL samples and necessitate no more than a simple motor to actuate fluid flow. The discs can be used to perform multiple extractions simultaneously as well as allowing the easy storage of samples before transport to the laboratory for LA-ICP-MS analysis.
- 1 October 2009
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 24 (11) , 1511-1516
Pre-concentration of trace metals on centrifugal microfluidic discs with direct determination by laser ablation inductively coupled plasma mass spectrometry
Solid Phase Extraction (SPE) is commonly used for pre-concentration and matrix removal in trace metal determinations. We present a novel centrifugal microfluidic device for field sampling and on-site pre-concentration of water samples. Metal-8-hydroxyquinoline complexes are adsorbed onto miniature C18-bonded silica gel columns on centrifugal microfluidic discs. Laser Ablation (LA) is used to directly vaporize the analytes from the column, instead of eluting the pre-concentrated analytes for introduction in an Inductively Coupled Plasma Mass Spectrometer (ICP-MS) by conventional solution nebulization. Absolute detection limits ranging between 0.1 and 12 ng were obtained for Ni, Cu, V, Pb and Co in drinking water Certified Reference Materials (CRMs). These centrifugal devices require only 1–600 µL samples and necessitate no more than a simple motor to actuate fluid flow. The discs can be used to perform multiple extractions simultaneously as well as allowing the easy storage of samples before transport to the laboratory for LA-ICP-MS analysis.
- 17 August 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (21) , 3151-3154
A rapid prototyping technique for valves and filters in centrifugal microfluidic devices
Using short lengths of fused silica capillary tubing embedded in the disk, a system for valving and filtering samples on centrifugal microfluidic devices has been designed and implemented. Sedimentation of turbid samples and transfer of the clear supernatant was also accomplished. Also demonstrated is the transfer of the liquid through a second capillary valve to the final reservoir. By controlling rotational speed, sedimentation and multiple step valving operations are readily implemented and easily prototyped.
- 17 August 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (21) , 3151-3154
A rapid prototyping technique for valves and filters in centrifugal microfluidic devices
Using short lengths of fused silica capillary tubing embedded in the disk, a system for valving and filtering samples on centrifugal microfluidic devices has been designed and implemented. Sedimentation of turbid samples and transfer of the clear supernatant was also accomplished. Also demonstrated is the transfer of the liquid through a second capillary valve to the final reservoir. By controlling rotational speed, sedimentation and multiple step valving operations are readily implemented and easily prototyped.