Thomas Kowpak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thomas Kowpak has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin R. Watts
Department of Engineering Physics, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L7, Canada
1 shared publication - Chang-Qing Xu
Department of Engineering Physics, McMaster University, Hamilton, ON L8S 4L7, Canada
1 shared publication - Min Lin
Ottawa Laboratory Fallowfield, Canadian Food Inspection Agency, Ottawa, Ontario, Canada
1 shared publication - Shiping Zhu
School of Science and Engineering, The Chinese University of Hong Kong, Shenzhen 518172, P. R. China
1 shared publication - Xudong Cao
Department of Chemical and Biological Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, ON, K1N 6N5, Canada
1 shared publication - Zhiyi Zhang
Quantum and Nanotechnologies Research Center National Research Council Canada 1200 Mon- treal Road K1A 0R6 Ottawa ON Canada
1 shared publication
Latest Publications
- Open Access
- 15 February 2012
- Published by MDPI AG in Micromachines
- Vol. 3 (1) , 62-77
Fabrication and Performance of a Photonic-Microfluidic Integrated Device
Fabrication and performance of a functional photonic-microfluidic flow cytometer is demonstrated. The devices are fabricated on a Pyrex substrate by photolithographically patterning the microchannels and optics in a SU-8 layer that is sealed via a poly(dimethylsiloxane) (PDMS) layer through a unique chemical bonding method. The resulting devices eliminate the free-space excitation optics through integration of microlenses onto the chip to mimic conventional cytometry excitation. Devices with beam waists of 6 μm and 12 μm in fluorescent detection and counting tests using 2.5 and 6 μm beads-show CVs of 9%–13% and 23% for the two devices, respectively. These results are within the expectations for a conventional cytometer (5%–15%) and demonstrate the ability to integrate the photonic components for excitation onto the chip and the ability to maintain the level of reliable detection.
- 15 February 2012
- Published by MDPI AG in Micromachines
- Vol. 3 (1) , 62-77
Open AccessFabrication and Performance of a Photonic-Microfluidic Integrated Device
Fabrication and performance of a functional photonic-microfluidic flow cytometer is demonstrated. The devices are fabricated on a Pyrex substrate by photolithographically patterning the microchannels and optics in a SU-8 layer that is sealed via a poly(dimethylsiloxane) (PDMS) layer through a unique chemical bonding method. The resulting devices eliminate the free-space excitation optics through integration of microlenses onto the chip to mimic conventional cytometry excitation. Devices with beam waists of 6 μm and 12 μm in fluorescent detection and counting tests using 2.5 and 6 μm beads-show CVs of 9%–13% and 23% for the two devices, respectively. These results are within the expectations for a conventional cytometer (5%–15%) and demonstrate the ability to integrate the photonic components for excitation onto the chip and the ability to maintain the level of reliable detection.