Andreas Ernst
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andreas Ernst has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Klaus Mutschler
Department of Microsystems Engineering, University of Freiburg, IMTEK, Georges-Köhler Allee 103, 79110 Freiburg, Germany
2 shared publications - Peter Koltay
Laboratory for MEMS Applications, IMTEK ‐ Department of Microsystems Engineering University of Freiburg Georges‐Koehler‐Allee 103 79110 Freiburg Germany
2 shared publications - Roland Zengerle
Laboratory for MEMS Applications, IMTEK-Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
2 shared publications - Dong Liang
Institut für Mikro- und Informationstechnik, HSG-IMIT, Wilhelm-Schickard-Straβe 10, 78052 Villingen-Schwenningen, Germany
1 shared publication - Laurent Tanguy
Institut für Mikro- und Informationstechnik, HSG-IMIT, Wilhelm-Schickard-Straβe 10, 78052 Villingen-Schwenningen, Germany
1 shared publication - Laurent Tanguy
Laboratory for MEMS Applications, Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110 Freiburg, Germany
1 shared publication
Latest Publications
- Open Access
- 28 February 2013
- Published by MDPI AG in Micromachines
- Vol. 4 (1) , 9-21
A Low-Cost, Normally Closed, Solenoid Valve for Non-Contact Dispensing in the Sub-µL Range
We present a disposable, normally closed, non-contact dispensing valve for the sub-µL range. The miniaturized solenoid valve (diameter: 8 mm, height: 27.25 mm) is compatible to standard Luer-Lock interfaces. A highly dynamic actuation principle enables opening times down to 1 ms. The dispensing performance was evaluated for water (η = 1.03 mPas) and a 66% (w/w) glycerol/water solution (η = 16.98 mPas), at pressures varying from 200 to 800 mbar. The experimentally determined minimal dispensing volume was 163 nL (CV 1.6%) for water and 123 nL (CV 4.5%) for 66% (w/w) glycerol/water. The low-cost polymer valve enables high precision dispensing of liquid volumes down to the lower end of the sub-µL range comparable to high-end non-disposable micro-dispensing valves.
- 28 February 2013
- Published by MDPI AG in Micromachines
- Vol. 4 (1) , 9-21
Open AccessA Low-Cost, Normally Closed, Solenoid Valve for Non-Contact Dispensing in the Sub-µL Range
We present a disposable, normally closed, non-contact dispensing valve for the sub-µL range. The miniaturized solenoid valve (diameter: 8 mm, height: 27.25 mm) is compatible to standard Luer-Lock interfaces. A highly dynamic actuation principle enables opening times down to 1 ms. The dispensing performance was evaluated for water (η = 1.03 mPas) and a 66% (w/w) glycerol/water solution (η = 16.98 mPas), at pressures varying from 200 to 800 mbar. The experimentally determined minimal dispensing volume was 163 nL (CV 1.6%) for water and 123 nL (CV 4.5%) for 66% (w/w) glycerol/water. The low-cost polymer valve enables high precision dispensing of liquid volumes down to the lower end of the sub-µL range comparable to high-end non-disposable micro-dispensing valves.
- Open Access
Numerical Investigations on Electric Field Characteristics with Respect to Capacitive Detection of Free-Flying Droplets
In this paper a multi-disciplinary simulation of a capacitive droplet sensor based on an open plate capacitor as transducing element is presented. The numerical simulations are based on the finite volume method (FVM), including calculations of an electric field which changes according to the presence of a liquid droplet. The volume of fluid (VOF) method is applied for the simulation of the ejection process of a liquid droplet out of a dispenser nozzle. The simulations were realised using the computational fluid dynamic (CFD) software CFD ACE+. The investigated capacitive sensing principle enables to determine the volume of a micro droplet passing the sensor capacitor due to the induced change in capacity. It could be found that single droplets in the considered volume range of 5 nL < Vdrop < 100 nL lead to a linear change of the capacity up to ΔQ < 30 fC. The sensitivity of the focused capacitor geometry was evaluated to be Si = 0.3 fC/nL. The simulation results are validated by experiments which exhibit good agreement.
Open AccessNumerical Investigations on Electric Field Characteristics with Respect to Capacitive Detection of Free-Flying Droplets
In this paper a multi-disciplinary simulation of a capacitive droplet sensor based on an open plate capacitor as transducing element is presented. The numerical simulations are based on the finite volume method (FVM), including calculations of an electric field which changes according to the presence of a liquid droplet. The volume of fluid (VOF) method is applied for the simulation of the ejection process of a liquid droplet out of a dispenser nozzle. The simulations were realised using the computational fluid dynamic (CFD) software CFD ACE+. The investigated capacitive sensing principle enables to determine the volume of a micro droplet passing the sensor capacitor due to the induced change in capacity. It could be found that single droplets in the considered volume range of 5 nL < Vdrop < 100 nL lead to a linear change of the capacity up to ΔQ < 30 fC. The sensitivity of the focused capacitor geometry was evaluated to be Si = 0.3 fC/nL. The simulation results are validated by experiments which exhibit good agreement.