TSTetsushi Sekiguchi

Tetsushi Sekiguchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tetsushi Sekiguchi has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dielectrophoresis-Based Selective Droplet Extraction Microfluidic Device for Single-Cell Analysis

    by Seito Shijo, Daiki Tanaka, Tetsushi Sekiguchi, Jun-Ichi Ishihara, Hiroki Takahashi, Masashi Kobayashi, Shuichi Shoji

    We developed a microfluidic device that enables selective droplet extraction from multiple droplet-trapping pockets based on dielectrophoresis. The device consists of a main microchannel, five droplet-trapping pockets with side channels, and drive electrode pairs appropriately located around the trapping pockets. Agarose droplets capable of encapsulating biological samples were successfully trapped in the trapping pockets due to the difference in flow resistance between the main and side channels. Target droplets were selectively extracted from the pockets by the dielectrophoretic force generated between the electrodes under an applied voltage of 500 V. During their extraction from the trapping pockets, the droplets and their contents were exposed to an electric field for 400–800 ms. To evaluate whether the applied voltage could potentially damage the biological samples, the growth rates of Escherichia coli cells in the droplets, with and without a voltage applied, were compared. No significant difference in the growth rate was observed. The developed device enables the screening of encapsulated single cells and the selective extraction of target droplets.


  • Open Access

    Controlling Microdroplet Inner Rotation by Parallel Carrier Flow of Sesame and Silicone Oils

    by Hibiki Yoshimura, Daiki Tanaka, Masahiro Furuya, Tetsushi Sekiguchi, Shuichi Shoji

    We developed a method for passively controlling microdroplet rotation, including interior rotation, using a parallel flow comprising silicone and sesame oils. This device has a simple 2D structure with a straight channel and T-junctions fabricated from polydimethylsiloxane. A microdroplet that forms upstream moves into the sesame oil. Then, the largest flow velocity at the interface of the two oil layers applies a rotational force to the microdroplet. A microdroplet in the lower oil rotates clockwise while that in the upper oil rotates anti-clockwise. The rotational direction was controlled by a simple combination of sesame and silicone oils. Droplet interior flow was visualized by tracking microbeads inside the microdroplets. This study will contribute to the efficient creation of chiral molecules for pharmaceutical and materials development by controlling rotational direction and speed.

  • Open Access

    Efficient Generation of Microdroplets Using Tail Breakup Induced with Multi-Branch Channels

    by Daiki Tanaka, Satsuki Kajiya, Seito Shijo, Dong Hyun Yoon, Masahiro Furuya, Yoshito Nozaki, Hiroyuki Fujita, Tetsushi Sekiguchi, Shuichi Shoji

    In recent years, research on the application of microdroplets in the fields of biotechnology and chemistry has made remarkable progress, but the technology for the stable generation of single-micrometer-scale microdroplets has not yet been established. In this paper, we developed an efficient and stable single-micrometer-scale droplet generation device based on the fragmentation of droplet tails, called “tail thread mode”, that appears under moderate flow conditions. This method can efficiently encapsulate microbeads that mimic cells and chemical products in passively generated single-micrometer-scale microdroplets. The device has a simple 2D structure; a T-junction is used for droplet generation; and in the downstream, multi-branch channels are designed for droplet deformation into the tail. Several 1–2 µm droplets were successfully produced by the tail’s fragmentation; this continuous splitting was induced by the branch channels. We examined a wide range of experimental conditions and found the optimal flow rate condition can be reduced to one-tenth compared to the conventional tip-streaming method. A mold was fabricated by simple soft lithography, and a polydimethylsiloxane (PDMS) device was fabricated using the mold. Based on the 15 patterns of experimental conditions and the results, the key factors for the generation of microdroplets in this device were examined. In the most efficient condition, 61.1% of the total droplets generated were smaller than 2 μm.


  • Open Access

    Development of Microdroplet Generation Method for Organic Solvents Used in Chemical Synthesis

    by Shohei Hattori, Chenghe Tang, Daiki Tanaka, Dong Hyun Yoon, Yoshito Nozaki, Hiroyuki Fujita, Takashiro Akitsu, Tetsushi Sekiguchi, Shuichi Shoji

    Recently, chemical operations with microfluidic devices, especially droplet-based operations, have attracted considerable attention because they can provide an isolated small-volume reaction field. However, analysis of these operations has been limited mostly to aqueous-phase reactions in water droplets due to device material restrictions. In this study, we have successfully demonstrated droplet formation of five common organic solvents frequently used in chemical synthesis by using a simple silicon/glass-based microfluidic device. When an immiscible liquid with surfactant was used as the continuous phase, the organic solvent formed droplets similar to water-in-oil droplets in the device. In contrast to conventional microfluidic devices composed of resins, which are susceptible to swelling in organic solvents, the developed microfluidic device did not undergo swelling owing to the high chemical resistance of the constituent materials. Therefore, the device has potential applications for various chemical reactions involving organic solvents. Furthermore, this droplet generation device enabled control of droplet size by adjusting the liquid flow rate. The droplet generation method proposed in this work will contribute to the study of organic reactions in microdroplets and will be useful for evaluating scaling effects in various chemical reactions.


  • Open Access

    Integration of Horizontal and Vertical Microfluidic Modules for Core-Shell Droplet Generation and Chemical Application

    by Dong Hyun Yoon, Yoshito Nozaki, Daiki Tanaka, Tetsushi Sekiguchi, Shuichi Shoji

    This paper presents a method for utilizing three-dimensional microfluidic channels fully to realize multiple functions in a single device. The final device structure was achieved by combining three independent modules that consisted of horizontal and vertical channels. The device allowed for the one-step generation of water-in-oil-in-water droplets without the need for partial treatment of the polydimethylsiloxane channel surface using separate modules for generating water-in-oil droplets on the horizontal plane and oil-in-water droplets on the vertical plane. The second vertically structured module provided an efficient flow for the generation of highly wettable liquid droplets, and tuning of the first horizontally structured module enabled different modes of inner-core encapsulation within the oil shell. The successful integration of the vertical and horizontal channels for core-shell droplet generation and the chemical synthesis of a metal complex within the droplets were evaluated. The proposed approach of integrating independent modules will expand and enhance the functions of microfluidic platforms.


  • Open Access

    Size-Dependent and Property-Independent Passive Microdroplet Sorting by Droplet Transfer on Dot Rails

    by Dong Hyun Yoon, Daiki Tanaka, Tetsushi Sekiguchi, Shuichi Shoji

    A fully passive microdroplet sorting method is presented in this paper. On the rails with dot patterns, the droplets were sorted in different ways depending on their size. However, the effect of droplet properties on the threshold size of the sorting was eliminated. The droplet positions on two railways and the Laplace pressure of the droplets on the dot patterns allowed selective droplet transfer according to size. Different gaps between the rails altered the threshold size of the transfer. However, the threshold size was independent of the droplet’s surface tension and viscosity because the droplet transfer utilized only the droplet position and Laplace pressure without lateral flow to sort targets. This feature has a high potential for bio/chemical applications requiring categorization of droplet targets consisting of various mixtures as pre- or post-elements.


  • Open Access

    Structural Formation of Oil-in-Water (O/W) and Water-in-Oil-in-Water (W/O/W) Droplets in PDMS Device Using Protrusion Channel without Hydrophilic Surface Treatment

    by Dong Hyun Yoon, Daiki Tanaka, Tetsushi Sekiguchi, Shuichi Shoji

    This paper presents a simple method of droplet formation using liquids that easily wet polydimethylsiloxane (PDMS) surfaces without any surface treatment. Using only structural features and uniform flow focusing, Oil-in-Water (O/W) and Water-in-Oil-in-Water (W/O/W) droplets were formed in the full PDMS structure. Extrusion channel and three-dimensional flow focusing resulted in effective fluidic conditions for droplet formation and the droplet size could be precisely controlled by controlling the flow rate of each phase. The proposed structure can be utilized as an important element for droplet based research, as well as a droplet generator.


  • Development of an ex vivo Brain Lactic Acid Monitoring System

    by Shuya Negishi, Shoto Kamada, Riichi Kajiwara, Yuji Kaneko, Dong Hyun Yoon, Tetsushi Sekiguchi, Shuichi Shoji, Hiroyuki Kudo

    An ex vivo brain lactic acid (LA) monitoring system for investigating brain activity at the organ level was constructed and tested in continuous LA monitoring. Our system consists of a micro-fluidic dual-analyte (LA and glucose) biosensor and a special brain chamber that is suitable for organ level experiments. The biosensor utilizes the redox reactions of osmium-wired horseradish peroxidase (Os-HRP) to detect hydrogen peroxide produced by enzyme reactions. The sensor had sufficient sensitivity (LA: ∼ 0.01 mM, glucose: ∼ 0.01 mM) and selectivity for assessment of extracellular LA. The ex vivo monitoring of brain LA was performed using the proposed system. As a result, the change in extracellular LA was successfully monitored continuously, and the change in the LA level was considered the result of metabolic activity of the sample. Our system is expected to be useful not only for ex vivo brain monitoring, but also for monitoring other organs.

  • Open Access

    3D Structures: Microfluidic Stamping on Sheath Flow (Small 24/2016)

    by Dong Hyun Yoon, Daiki Tanaka, Tetsushi Sekiguchi, Shuichi Shoji

  • Microfluidic Stamping on Sheath Flow

    by Dong Hyun Yoon, Daiki Tanaka, Tetsushi Sekiguchi, Shuichi Shoji