Roland Zengerle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Roland Zengerle has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Simon Thiele
Forschungszentrum Jülich GmbH, HI ERN (IEK-11)
3 shared publications - Sven Kerzenmacher
Center for Environmental Research and Sustainable Technology (UFT), University of Bremen, Bremen, Germany
3 shared publications - Felix von Stetten
HSG-IMIT-Institut für Mikro- und Informationstechnik, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
2 shared publications - Johannes Gescher
Hamburg University of Technology
2 shared publications - Katrin Richter
Institute for Applied Biosciences, Department of Applied Biology, Karlsruhe Institute of Technology, Karlsruhe, Germany
2 shared publications - Lukas Zielke
Laboratory for MEMS Applications
2 shared publications
Latest Publications
- Open Access
- 3 September 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (9) , 312
Real-Time Detection of Tumor Cells during Capture on a Filter Element Significantly Enhancing Detection Rate
Circulating tumor cells (CTCs) that enter the bloodstream play an important role in the formation of metastases. The prognostic significance of CTCs as biomarkers obtained from liquid biopsies is intensively investigated and requires accurate methods for quantification. The purpose of this study was the capture of CTCs on an optically accessible surface for real-time quantification. A filtration device was fabricated from a transparent material so that capturing of cells could be observed microscopically. Blood samples were spiked with stained tumor cells and the sample was filtrated using a porous structure with pore sizes of 7.4 µm. The possible removal of lysed erythrocytes and the retention of CTCs were assessed. The filtration process was observed in real-time using fluorescence microscopy, whereby arriving cells were counted in order to determine the number of CTCs present in the blood. Through optimization of the microfluidic channel design, the cell retention rate could be increased by 13% (from 76% ± 7% to 89% ± 5%). Providing the possibility for real-time detection significantly improved quantification efficiency even for the smallest cells evaluated. While end-point evaluation resulted in a detection rate of 63% ± 3% of the spiked cells, real-time evaluation led to an increase of 21% to 84% ± 4%. The established protocol provides an advantageous and efficient method for integration of fully automated sample preparation and CTC quantification into a lab-on-a-chip system.
- 3 September 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (9) , 312
Open AccessReal-Time Detection of Tumor Cells during Capture on a Filter Element Significantly Enhancing Detection Rate
Circulating tumor cells (CTCs) that enter the bloodstream play an important role in the formation of metastases. The prognostic significance of CTCs as biomarkers obtained from liquid biopsies is intensively investigated and requires accurate methods for quantification. The purpose of this study was the capture of CTCs on an optically accessible surface for real-time quantification. A filtration device was fabricated from a transparent material so that capturing of cells could be observed microscopically. Blood samples were spiked with stained tumor cells and the sample was filtrated using a porous structure with pore sizes of 7.4 µm. The possible removal of lysed erythrocytes and the retention of CTCs were assessed. The filtration process was observed in real-time using fluorescence microscopy, whereby arriving cells were counted in order to determine the number of CTCs present in the blood. Through optimization of the microfluidic channel design, the cell retention rate could be increased by 13% (from 76% ± 7% to 89% ± 5%). Providing the possibility for real-time detection significantly improved quantification efficiency even for the smallest cells evaluated. While end-point evaluation resulted in a detection rate of 63% ± 3% of the spiked cells, real-time evaluation led to an increase of 21% to 84% ± 4%. The established protocol provides an advantageous and efficient method for integration of fully automated sample preparation and CTC quantification into a lab-on-a-chip system.
- Open Access
- 19 August 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (84) , 80700-80705
Three-dimensional morphology of the interface between micro porous layer and catalyst layer in a polymer electrolyte membrane fuel cell
Interfaces between the different layers in proton exchange membrane fuel cells are expected to influence transport properties and therefore cell performance. So far the interface between micro porous layer (MPL) and catalyst layer (CL) has been difficult to investigate due to its nanometer scale morphology. We apply focused ion beam scanning electron microscopy tomography with pore contrasting via atomic layer deposition to reconstruct a representative volume of 5.1 μm × 1.5 μm × 4.5 μm containing CL, MPL and their interface. We find that platinum in the CL results in brighter SEM image intensities, compared to the MPL. This allows (i) estimating the extension of the interfacial region (530 nm), (ii) evaluating Pt-content homogeneity in the CL and (iii) calculating the individual roughnesses for the CL (102 nm) and for the MPL (129 nm). We further calculate porosity, pore sizes, and oxygen diffusivities. Thus, we find that the values of the parameters of the interfacial region are between those of the CL and the MPL, meaning that on the investigated scale, the interface is a homogeneous transitional region. A representativeness analysis shows that our reconstructed volume is sufficiently large concerning all calculated parameters.
- 19 August 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (84) , 80700-80705
Open AccessThree-dimensional morphology of the interface between micro porous layer and catalyst layer in a polymer electrolyte membrane fuel cell
Interfaces between the different layers in proton exchange membrane fuel cells are expected to influence transport properties and therefore cell performance. So far the interface between micro porous layer (MPL) and catalyst layer (CL) has been difficult to investigate due to its nanometer scale morphology. We apply focused ion beam scanning electron microscopy tomography with pore contrasting via atomic layer deposition to reconstruct a representative volume of 5.1 μm × 1.5 μm × 4.5 μm containing CL, MPL and their interface. We find that platinum in the CL results in brighter SEM image intensities, compared to the MPL. This allows (i) estimating the extension of the interfacial region (530 nm), (ii) evaluating Pt-content homogeneity in the CL and (iii) calculating the individual roughnesses for the CL (102 nm) and for the MPL (129 nm). We further calculate porosity, pore sizes, and oxygen diffusivities. Thus, we find that the values of the parameters of the interfacial region are between those of the CL and the MPL, meaning that on the investigated scale, the interface is a homogeneous transitional region. A representativeness analysis shows that our reconstructed volume is sufficiently large concerning all calculated parameters.
- 1 January 2016
- Vol. 224, 61-6
Chair/bedside diagnosis of oral and respiratory tract infections, and identification of antibiotic resistances for personalised monitoring and treatment.
Global healthcare systems are struggling with the enormous burden associated with infectious diseases, as well as the incessant rise of antimicrobial resistance. In order to adequately address these issues, there is an urgent need for rapid and accurate infectious disease diagnostics. The H2020 project DIAGORAS aims at diagnosing oral and respiratory tract infections using a fully integrated, automated and user-friendly platform for physicians' offices, schools, elderly care units, community settings, etc. Oral diseases (periodontitis, dental caries) will be detected via multiplexed, quantitative analysis of salivary markers (bacterial DNA and host response proteins) for early prevention and personalised monitoring. Respiratory Tract Infections will be diagnosed by means of DNA/RNA differentiation so as to identify their bacterial or viral nature. Together with antibiotic resistance screening on the same platform, a more efficient treatment management is expected at the point-of-care. At the heart of DIAGORAS lies a centrifugal microfluidic platform (LabDisk and associated processing device) integrating all components and assays for a fully automated analysis. The project involves an interface with a clinical algorithm for the comprehensive presentation of results to end-users, thereby increasing the platform's clinical utility. DIAGORAS' performance will be validated at clinical settings and compared with gold standards.
- 1 January 2016
- Vol. 224, 61-6
Chair/bedside diagnosis of oral and respiratory tract infections, and identification of antibiotic resistances for personalised monitoring and treatment.
Global healthcare systems are struggling with the enormous burden associated with infectious diseases, as well as the incessant rise of antimicrobial resistance. In order to adequately address these issues, there is an urgent need for rapid and accurate infectious disease diagnostics. The H2020 project DIAGORAS aims at diagnosing oral and respiratory tract infections using a fully integrated, automated and user-friendly platform for physicians' offices, schools, elderly care units, community settings, etc. Oral diseases (periodontitis, dental caries) will be detected via multiplexed, quantitative analysis of salivary markers (bacterial DNA and host response proteins) for early prevention and personalised monitoring. Respiratory Tract Infections will be diagnosed by means of DNA/RNA differentiation so as to identify their bacterial or viral nature. Together with antibiotic resistance screening on the same platform, a more efficient treatment management is expected at the point-of-care. At the heart of DIAGORAS lies a centrifugal microfluidic platform (LabDisk and associated processing device) integrating all components and assays for a fully automated analysis. The project involves an interface with a clinical algorithm for the comprehensive presentation of results to end-users, thereby increasing the platform's clinical utility. DIAGORAS' performance will be validated at clinical settings and compared with gold standards.
- Open Access
- 2 April 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 3 (21) , 11239-11245
Direct deposition of proton exchange membranes enabling high performance hydrogen fuel cells
We apply drop-on-demand inkjet printing to fabricate proton exchange membranes for polymer electrolyte fuel cells. This completely substitutes the commonly used membrane foil. A Nafion® dispersion is deposited directly onto the catalyst layers of anode and cathode gas diffusion electrodes, and the two electrodes are pressed together with the membrane layers facing each other. Fuel cells constructed utilizing this method reveal a thin overall membrane thickness of 8–25 μm and a good adhesion of membrane and catalyst layers. This results in a membrane ionic resistance of only 12.7 mΩ cm2 without compromising hydrogen crossover, which was determined to be less than 2 mA cm−2. We achieve a cell power density exceeding 4 W cm−2 with pure oxygen as cathode fuel, which, to our knowledge, is the highest reported power density with a Nafion® membrane hydrogen fuel cell. The membrane shows a stable performance over the entire range of reactant gas humidification from 0 to 100% relative humidity. Power densities exceeding 1.0 W cm−2 are achieved under dry operation with air as cathode fuel. A 576 hour combined mechanical and chemical accelerated stress test reveals no significant degradation in terms of hydrogen crossover, indicating a promising lifetime of the membrane.
- 2 April 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 3 (21) , 11239-11245
Open AccessDirect deposition of proton exchange membranes enabling high performance hydrogen fuel cells
We apply drop-on-demand inkjet printing to fabricate proton exchange membranes for polymer electrolyte fuel cells. This completely substitutes the commonly used membrane foil. A Nafion® dispersion is deposited directly onto the catalyst layers of anode and cathode gas diffusion electrodes, and the two electrodes are pressed together with the membrane layers facing each other. Fuel cells constructed utilizing this method reveal a thin overall membrane thickness of 8–25 μm and a good adhesion of membrane and catalyst layers. This results in a membrane ionic resistance of only 12.7 mΩ cm2 without compromising hydrogen crossover, which was determined to be less than 2 mA cm−2. We achieve a cell power density exceeding 4 W cm−2 with pure oxygen as cathode fuel, which, to our knowledge, is the highest reported power density with a Nafion® membrane hydrogen fuel cell. The membrane shows a stable performance over the entire range of reactant gas humidification from 0 to 100% relative humidity. Power densities exceeding 1.0 W cm−2 are achieved under dry operation with air as cathode fuel. A 576 hour combined mechanical and chemical accelerated stress test reveals no significant degradation in terms of hydrogen crossover, indicating a promising lifetime of the membrane.
- Open Access
- 31 October 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (102) , 58888-58894
Tomography based screening of flow field / current collector combinations for PEM water electrolysis
Current collectors in PEM water electrolysis perform several functions that influence overall performance. These include conducting heat and electrons, as well as transporting water and gas. X-ray tomography, standardized reconstruction, and calculation methods are used to compare the morphological and transport parameters of eight different current collectors functioning as flow fields for PEM water electrolysis. We find simple exponential relations between through-plane thermal conductivity λ and porosity p (λ20°C(p) = 1749p−1.306 − 4.420), as well as between through-plane electrical conductivity σ and water permeability K (σ(K) = 10−6 × K−0.6376). In addition, we use both local and global concepts to investigate the pore space of current collectors. We hereby investigate homogeneity and characteristic sizes, like mean pore diameter or mean distance between solid parts at the catalytic interface. Moreover, we find that the local concept of mean chord lengths can be used to explain electrical and thermal conductivity anisotropies. These chords can be used to predict the direction of the largest conductivity for fibrous current collectors.
- 31 October 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (102) , 58888-58894
Open AccessTomography based screening of flow field / current collector combinations for PEM water electrolysis
Current collectors in PEM water electrolysis perform several functions that influence overall performance. These include conducting heat and electrons, as well as transporting water and gas. X-ray tomography, standardized reconstruction, and calculation methods are used to compare the morphological and transport parameters of eight different current collectors functioning as flow fields for PEM water electrolysis. We find simple exponential relations between through-plane thermal conductivity λ and porosity p (λ20°C(p) = 1749p−1.306 − 4.420), as well as between through-plane electrical conductivity σ and water permeability K (σ(K) = 10−6 × K−0.6376). In addition, we use both local and global concepts to investigate the pore space of current collectors. We hereby investigate homogeneity and characteristic sizes, like mean pore diameter or mean distance between solid parts at the catalytic interface. Moreover, we find that the local concept of mean chord lengths can be used to explain electrical and thermal conductivity anisotropies. These chords can be used to predict the direction of the largest conductivity for fibrous current collectors.
- 1 April 2014
- Published by Elsevier in Bioresource Technology
- Vol. 158, 231-238
Using planktonic microorganisms to supply the unpurified multi-copper oxidases laccase and copper efflux oxidases at a biofuel cell cathode
- 1 April 2014
- Published by Elsevier in Bioresource Technology
- Vol. 158, 231-238
Using planktonic microorganisms to supply the unpurified multi-copper oxidases laccase and copper efflux oxidases at a biofuel cell cathode
- 1 October 2013
- Published by Elsevier in Bioresource Technology
- Vol. 146, 386-392
Systematic screening of carbon-based anode materials for microbial fuel cells with Shewanella oneidensis MR-1
- 1 October 2013
- Published by Elsevier in Bioresource Technology
- Vol. 146, 386-392
Systematic screening of carbon-based anode materials for microbial fuel cells with Shewanella oneidensis MR-1
- Open Access
- 14 March 2013
- Published by MDPI AG in Micromachines
- Vol. 4 (1) , 80-89
Active Continuous-Flow Micromixer Using an External Braille Pin Actuator Array
We present a continuous-flow active micromixer based on channel-wall deflection in a polydimethylsiloxane (PDMS) chip for volume flows in the range up to 2 μL s−1 which is intended as a novel unit operation for the microfluidic Braille pin actuated platform. The chip design comprises a main microchannel connected to a series of side channels with dead ends aligned on the Braille pins. Computer-controlled deflection of the side-channel walls induces chaotic advection in the main-channel, which substantially accelerates mixing in low-Reynolds number flow. Sufficient mixing (mixing index MI below 0.1) of volume flows up to 0.5 μL s−1 could be achieved within residence times ~500 ms in the micromixer. As an application, continuous dilution of a yeast cell sample by a ratio down to 1:10 was successfully demonstrated. The mixer is intended to serve as a component of bio-analytical devices or as a unit operation in the microfluidic Braille pin actuated platform.
- 14 March 2013
- Published by MDPI AG in Micromachines
- Vol. 4 (1) , 80-89
Open AccessActive Continuous-Flow Micromixer Using an External Braille Pin Actuator Array
We present a continuous-flow active micromixer based on channel-wall deflection in a polydimethylsiloxane (PDMS) chip for volume flows in the range up to 2 μL s−1 which is intended as a novel unit operation for the microfluidic Braille pin actuated platform. The chip design comprises a main microchannel connected to a series of side channels with dead ends aligned on the Braille pins. Computer-controlled deflection of the side-channel walls induces chaotic advection in the main-channel, which substantially accelerates mixing in low-Reynolds number flow. Sufficient mixing (mixing index MI below 0.1) of volume flows up to 0.5 μL s−1 could be achieved within residence times ~500 ms in the micromixer. As an application, continuous dilution of a yeast cell sample by a ratio down to 1:10 was successfully demonstrated. The mixer is intended to serve as a component of bio-analytical devices or as a unit operation in the microfluidic Braille pin actuated platform.
- 15 October 2010
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 26 (2) , 841-845
Carbon electrodes for direct electron transfer type laccase cathodes investigated by current density–cathode potential behavior
- 15 October 2010
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 26 (2) , 841-845
Carbon electrodes for direct electron transfer type laccase cathodes investigated by current density–cathode potential behavior
- 8 May 2010
- Published by Springer Nature
- p. 305-376
Microfluidic Lab-on-a-Chip Platforms: Requirements, Characteristics and Applications
- 8 May 2010
- Published by Springer Nature
- p. 305-376
Microfluidic Lab-on-a-Chip Platforms: Requirements, Characteristics and Applications