Bruce S. Edwards has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Eric R. Prossnitz
University of New Mexico Albuquerque USA
6 shared publications Larry A. Sklar
Center for Molecular Discovery, Innovation Discovery and Training Center, Health Sciences Center, University of New Mexico, Albuquerque, NM, USA
6 shared publications- Larry A. Sklar
Cytometry, Cancer Research and Treatment Center, University of New Mexico Health Sciences Center, Albuquerque, New Mexico
5 shared publications - Cristian G. Bologa
Department of Internal Medicine, School of Medicine, University of New Mexico Health Sciences Center, 1 University of New Mexico, MSC10 5550, Albuquerque, NM, 87131, United States, 1 505-272-9709
3 shared publications Larry A Sklar
3 shared publicationsRichard D. Ye
Cancer Research and Treatment Center, University of New Mexico
3 shared publications
Latest Publications
- Open Access
- 1 August 2018
- Published by Elsevier in SLAS Discovery
- Vol. 23 (7) , 599-602
High-Throughput Flow Cytometry in Drug Discovery
- 1 August 2018
- Published by Elsevier in SLAS Discovery
- Vol. 23 (7) , 599-602
Open AccessHigh-Throughput Flow Cytometry in Drug Discovery
- Open Access
- 1 July 2015
- Published by Elsevier in SLAS Discovery
- Vol. 20 (6) , 689-707
Flow Cytometry: Impact on Early Drug Discovery
- 1 July 2015
- Published by Elsevier in SLAS Discovery
- Vol. 20 (6) , 689-707
Open AccessFlow Cytometry: Impact on Early Drug Discovery
- Open Access
The Mathematics of a Successful Deconvolution: A Quantitative Assessment of Mixture-Based Combinatorial Libraries Screened Against Two Formylpeptide Receptors
In the past 20 years, synthetic combinatorial methods have fundamentally advanced the ability to synthesize and screen large numbers of compounds for drug discovery and basic research. Mixture-based libraries and positional scanning deconvolution combine two approaches for the rapid identification of specific scaffolds and active ligands. Here we present a quantitative assessment of the screening of 32 positional scanning libraries in the identification of highly specific and selective ligands for two formylpeptide receptors. We also compare and contrast two mixture-based library approaches using a mathematical model to facilitate the selection of active scaffolds and libraries to be pursued for further evaluation. The flexibility demonstrated in the differently formatted mixture-based libraries allows for their screening in a wide range of assays.
Open AccessThe Mathematics of a Successful Deconvolution: A Quantitative Assessment of Mixture-Based Combinatorial Libraries Screened Against Two Formylpeptide Receptors
In the past 20 years, synthetic combinatorial methods have fundamentally advanced the ability to synthesize and screen large numbers of compounds for drug discovery and basic research. Mixture-based libraries and positional scanning deconvolution combine two approaches for the rapid identification of specific scaffolds and active ligands. Here we present a quantitative assessment of the screening of 32 positional scanning libraries in the identification of highly specific and selective ligands for two formylpeptide receptors. We also compare and contrast two mixture-based library approaches using a mathematical model to facilitate the selection of active scaffolds and libraries to be pursued for further evaluation. The flexibility demonstrated in the differently formatted mixture-based libraries allows for their screening in a wide range of assays.
- Open Access
- 21 March 2012
- Published by Wiley in Cytometry Part A
- Vol. 81 (5) , 419-429
Cluster cytometry for high-capacity bioanalysis
- 21 March 2012
- Published by Wiley in Cytometry Part A
- Vol. 81 (5) , 419-429
Open AccessCluster cytometry for high-capacity bioanalysis
- 9 June 2011
- Published by Springer Nature in Nature Protocols
- Vol. 6 (7) , 943-952
Simultaneous in vitro molecular screening of protein-peptide interactions by flow cytometry, using six Bcl-2 family proteins as examples
The B-cell lymphoma-2 (Bcl-2) family contains six antiapoptotic members, each with a hydrophobic pocket in which Bcl-2 homology region 3 (BH3) helices bind. This binding quenches apoptotic signals from activated BH3 family members. Many tumor cells either have increased expression of one of these six proteins or become overexpressed under treatment. Six fusion proteins made up of glutathione-S-transferase and each of the Bcl-2 members are bound individually to six glutathione bead sets, each set being easily distinguished by its different intensity of red fluorescence. The coated bead sets are washed, combined and incubated with green fluorescent Bim-BH3 peptide and a small molecule in 10-μl wells for 1 h. The green fluorescence signal for each bead set is resolved, and selective inhibitors are expected to reduce the signal for individual bead sets. Each 384-well plate is analyzed in 12 min, measuring 200 of 2,000 beads (∼10%) of each type per well.
- 9 June 2011
- Published by Springer Nature in Nature Protocols
- Vol. 6 (7) , 943-952
Simultaneous in vitro molecular screening of protein-peptide interactions by flow cytometry, using six Bcl-2 family proteins as examples
The B-cell lymphoma-2 (Bcl-2) family contains six antiapoptotic members, each with a hydrophobic pocket in which Bcl-2 homology region 3 (BH3) helices bind. This binding quenches apoptotic signals from activated BH3 family members. Many tumor cells either have increased expression of one of these six proteins or become overexpressed under treatment. Six fusion proteins made up of glutathione-S-transferase and each of the Bcl-2 members are bound individually to six glutathione bead sets, each set being easily distinguished by its different intensity of red fluorescence. The coated bead sets are washed, combined and incubated with green fluorescent Bim-BH3 peptide and a small molecule in 10-μl wells for 1 h. The green fluorescence signal for each bead set is resolved, and selective inhibitors are expected to reduce the signal for individual bead sets. Each 384-well plate is analyzed in 12 min, measuring 200 of 2,000 beads (∼10%) of each type per well.
- Open Access
- 13 March 2009
- Published by Springer Nature
- Vol. 486, 151-165
High-Content Screening: Flow Cytometry Analysis
The HyperCyt® high-throughput (HT) flow cytometry sampling platform uses a peristaltic pump, in combination with an autosampler, and a novel approach to data collection, to circumvent time-delay bottlenecks of conventional flow cytometry. This approach also dramatically reduces the amount of sample aspirated for each analysis, typically requiring ~2 μL per sample while making quantitative fluorescence measurements of 40 or more samples per minute with thousands to tens of thousands of cells in each sample. Here, we describe a simple robust screening assay that exploits the high-content measurement capabilities of the flow cytometer to simultaneously probe the binding of test compounds to two different receptors in a common assay volume, a duplex assay format. The ability of the flow cytometer to distinguish cell-bound from free fluorophore is also exploited to eliminate wash steps during assay setup. HT flow cytometry with this assay has allowed efficient screening of tens of thousands of small molecules from the NIH Small-Molecule Repository to identify selective ligands for two related G-protein-coupled receptors, the formylpeptide receptor and formylpeptide receptor-like 1.
- 13 March 2009
- Published by Springer Nature
- Vol. 486, 151-165
Open AccessHigh-Content Screening: Flow Cytometry Analysis
The HyperCyt® high-throughput (HT) flow cytometry sampling platform uses a peristaltic pump, in combination with an autosampler, and a novel approach to data collection, to circumvent time-delay bottlenecks of conventional flow cytometry. This approach also dramatically reduces the amount of sample aspirated for each analysis, typically requiring ~2 μL per sample while making quantitative fluorescence measurements of 40 or more samples per minute with thousands to tens of thousands of cells in each sample. Here, we describe a simple robust screening assay that exploits the high-content measurement capabilities of the flow cytometer to simultaneously probe the binding of test compounds to two different receptors in a common assay volume, a duplex assay format. The ability of the flow cytometer to distinguish cell-bound from free fluorophore is also exploited to eliminate wash steps during assay setup. HT flow cytometry with this assay has allowed efficient screening of tens of thousands of small molecules from the NIH Small-Molecule Repository to identify selective ligands for two related G-protein-coupled receptors, the formylpeptide receptor and formylpeptide receptor-like 1.
- Open Access
- 11 November 2008
- Published by Wiley in Cytometry Part A
- Vol. 75A (3) , 264-270
A novel fluorescent cross‐reactive formylpeptide receptor/formylpeptide receptor‐like 1 hexapeptide ligand
Formylpeptide receptors (FPRs) are implicated in a variety of immunological and inflammatory response cascades. Further understanding of FPR‐family ligand interactions could play an integral role in biological and therapeutic discovery. Fluorescent reporter ligands for the family are desirable experimental tools for increased understanding of ligand/receptor interactions. The ligand binding affinity and fluorescent reporting activity of the peptide WK(FL)YMVm was explored though use of the high throughput HyperCyt® flow cytometric platform. Relative binding affinities of several known FPR and FPRL1 peptide ligands were compared in a duplex assay format. The fluorescent W‐peptide ligand, WK(FL)YMVm, proved to be a high‐affinity, cross‐reactive reporter ligand for the FPR/FPRL1 duplex assay. Ligand specificity was demonstrated for each receptor, with known, selective peptide ligands. The binding site specificity of the reporter ligand was further verified by a fluorescent confocal microscopy internalization experiment. The fluorescent peptide ligand WK(FL)YMVm binds with high affinity to both FPR and FPRL1. The differential affinities of known peptide ligands were observed with the use of this fluorescent probe in high throughput screening flow cytometry. © 2008 International Society for Advancement of Cytometry
- 11 November 2008
- Published by Wiley in Cytometry Part A
- Vol. 75A (3) , 264-270
Open AccessA novel fluorescent cross‐reactive formylpeptide receptor/formylpeptide receptor‐like 1 hexapeptide ligand
Formylpeptide receptors (FPRs) are implicated in a variety of immunological and inflammatory response cascades. Further understanding of FPR‐family ligand interactions could play an integral role in biological and therapeutic discovery. Fluorescent reporter ligands for the family are desirable experimental tools for increased understanding of ligand/receptor interactions. The ligand binding affinity and fluorescent reporting activity of the peptide WK(FL)YMVm was explored though use of the high throughput HyperCyt® flow cytometric platform. Relative binding affinities of several known FPR and FPRL1 peptide ligands were compared in a duplex assay format. The fluorescent W‐peptide ligand, WK(FL)YMVm, proved to be a high‐affinity, cross‐reactive reporter ligand for the FPR/FPRL1 duplex assay. Ligand specificity was demonstrated for each receptor, with known, selective peptide ligands. The binding site specificity of the reporter ligand was further verified by a fluorescent confocal microscopy internalization experiment. The fluorescent peptide ligand WK(FL)YMVm binds with high affinity to both FPR and FPRL1. The differential affinities of known peptide ligands were observed with the use of this fluorescent probe in high throughput screening flow cytometry. © 2008 International Society for Advancement of Cytometry
- Open Access
- 10 September 2008
- Published by Wiley in Cytometry Part A
- Vol. 75A (3) , 253-263
Duplex high‐throughput flow cytometry screen identifies two novel formylpeptide receptor family probes
Of recent, clinical interest have been two related human G‐protein coupled receptors: formylpeptide receptor (FPR), linked to antibacterial inflammation and malignant glioma cell metastasis; and FPR like‐1 (FPRL1), linked to chronic inflammation in systemic amyloidosis, Alzheimer's disease, and prion diseases. In association with the National Institutes of Health (NIH) Molecular Library Screening Network, we implemented a flow‐cytometry‐based high‐throughput screening (HTS) approach for identifying selective small molecule FPR and FPRL1 ligands. The screening assay measured the ability of test compounds to competitively displace a high‐affinity, fluorescein‐ labeled peptide ligand from FPR, FPRL1, or both. U937 cells expressing FPR and rat basophil leukemia (RBL) cells expressing FPRL1 were tested together in a “duplex” format. The U937 cells were color coded with red‐fluorescent dye allowing their distinction during analysis. Compounds, cells, and fluorescent ligand were sequentially combined (no wash) in 15 μl assay volumes in 384‐well plates. Throughput averaged ∼11 min per plate to analyze ∼4,000 cells (∼2,000/receptor) in a 2 μl aspirate from each well. In primary single concentration HTS of 24,304 NIH Small Molecule Repository compounds, 253 resulted in inhibition >30% (181 for FPR, 72 for FPRL1) of which 40 had selective binding inhibition constants (Ki) ≤ 4 μM (34 for FPR and 6 for FPRL1). An additional 1,446 candidate compounds were selected by structure–activity‐relationship analysis of the hits and screened to identify novel ligands for FPR (3570‐0208, Ki = 95 ± 10 nM) and FPRL1 (BB‐V‐115, Ki = 270 ± 51 nM). Each was a selective antagonist in calcium response assays and the most potent small molecule antagonist reported for its respective receptor to date. The duplex assay format reduced assay time, minimized reagent requirements, and provided selectivity information at every screening stage, thus proving to be an efficient means to screen for selective receptor ligand probes. © 2008 International Society for Advancement of Cytometry
- 10 September 2008
- Published by Wiley in Cytometry Part A
- Vol. 75A (3) , 253-263
Open AccessDuplex high‐throughput flow cytometry screen identifies two novel formylpeptide receptor family probes
Of recent, clinical interest have been two related human G‐protein coupled receptors: formylpeptide receptor (FPR), linked to antibacterial inflammation and malignant glioma cell metastasis; and FPR like‐1 (FPRL1), linked to chronic inflammation in systemic amyloidosis, Alzheimer's disease, and prion diseases. In association with the National Institutes of Health (NIH) Molecular Library Screening Network, we implemented a flow‐cytometry‐based high‐throughput screening (HTS) approach for identifying selective small molecule FPR and FPRL1 ligands. The screening assay measured the ability of test compounds to competitively displace a high‐affinity, fluorescein‐ labeled peptide ligand from FPR, FPRL1, or both. U937 cells expressing FPR and rat basophil leukemia (RBL) cells expressing FPRL1 were tested together in a “duplex” format. The U937 cells were color coded with red‐fluorescent dye allowing their distinction during analysis. Compounds, cells, and fluorescent ligand were sequentially combined (no wash) in 15 μl assay volumes in 384‐well plates. Throughput averaged ∼11 min per plate to analyze ∼4,000 cells (∼2,000/receptor) in a 2 μl aspirate from each well. In primary single concentration HTS of 24,304 NIH Small Molecule Repository compounds, 253 resulted in inhibition >30% (181 for FPR, 72 for FPRL1) of which 40 had selective binding inhibition constants (Ki) ≤ 4 μM (34 for FPR and 6 for FPRL1). An additional 1,446 candidate compounds were selected by structure–activity‐relationship analysis of the hits and screened to identify novel ligands for FPR (3570‐0208, Ki = 95 ± 10 nM) and FPRL1 (BB‐V‐115, Ki = 270 ± 51 nM). Each was a selective antagonist in calcium response assays and the most potent small molecule antagonist reported for its respective receptor to date. The duplex assay format reduced assay time, minimized reagent requirements, and provided selectivity information at every screening stage, thus proving to be an efficient means to screen for selective receptor ligand probes. © 2008 International Society for Advancement of Cytometry
- 1 May 2007
- Published by Taylor & Francis in Expert Opinion on Drug Discovery
- Vol. 2 (5) , 685-696
High-throughput flow cytometry for drug discovery
High-throughput flow cytometry exploits a novel many-samples/one-file approach to dramatically speed data acquisition, limit aspirated sample volume to as little as 2 μl/well and produce multisample data sets that facilitate automated analysis of samples in groups as well as individually. It has been successfully applied to both cell- and microsphere-based bioassays in 96- and 384-well formats, to screen tens-of-thousands of compounds and identify novel bioactive structures. High-content multiparametric analysis capabilities have been exploited for assay multiplexing, allowing the assessment of biologic selectivity and specificity to be an integral component of primary screens. These and other advances in the last decade have contributed to the application of flow cytometry as a uniquely powerful tool for probing biologic and chemical diversity and complex systems biology.
- 1 May 2007
- Published by Taylor & Francis in Expert Opinion on Drug Discovery
- Vol. 2 (5) , 685-696
High-throughput flow cytometry for drug discovery
High-throughput flow cytometry exploits a novel many-samples/one-file approach to dramatically speed data acquisition, limit aspirated sample volume to as little as 2 μl/well and produce multisample data sets that facilitate automated analysis of samples in groups as well as individually. It has been successfully applied to both cell- and microsphere-based bioassays in 96- and 384-well formats, to screen tens-of-thousands of compounds and identify novel bioactive structures. High-content multiparametric analysis capabilities have been exploited for assay multiplexing, allowing the assessment of biologic selectivity and specificity to be an integral component of primary screens. These and other advances in the last decade have contributed to the application of flow cytometry as a uniquely powerful tool for probing biologic and chemical diversity and complex systems biology.
- 27 June 2006
- Published by Springer Nature in Nature Protocols
- Vol. 1 (1) , 59-66
Biomolecular screening of formylpeptide receptor ligands with a sensitive, quantitative, high-throughput flow cytometry platform
The formylpeptide receptor (FPR) family of G protein–coupled receptors contributes to the localization and activation of tissue-damaging leukocytes at sites of chronic inflammation. Here we describe a high-throughput flow cytometry screening approach that has successfully identified multiple families of previously unknown FPR ligands. The assay detects active structures that block the binding of a fluorescent ligand to membrane FPR of intact cells, thus detecting both agonists and antagonists. It is homogeneous in that assay reagents are added in sequence and the wells are subsequently analyzed without intervening wash steps. Microplate wells are routinely processed at a rate of 40 wells per minute, requiring a volume of only 2 μl to be sampled from each. This screening approach has recently been extended to identify a high-affinity, selective agonist for the intracellular estrogen-binding G protein–coupled receptor GPR30. With the development of appropriate assay reagents, it may be generally adaptable to a wide range of receptors. The total time required for the assay ranges between 1.5 and 2.5 h. The time required for flow cytometry analysis of a 96-well plate at the end of the procedure is less than 2.5 min. By comparison, manual processing of 96 samples will typically require 40–50 min, and a fast commercial automated sampler processes 96-well plates in less than 15 min, requiring the aspiration of 22 μl per sample for an analysis volume of 2 μl.
- 27 June 2006
- Published by Springer Nature in Nature Protocols
- Vol. 1 (1) , 59-66
Biomolecular screening of formylpeptide receptor ligands with a sensitive, quantitative, high-throughput flow cytometry platform
The formylpeptide receptor (FPR) family of G protein–coupled receptors contributes to the localization and activation of tissue-damaging leukocytes at sites of chronic inflammation. Here we describe a high-throughput flow cytometry screening approach that has successfully identified multiple families of previously unknown FPR ligands. The assay detects active structures that block the binding of a fluorescent ligand to membrane FPR of intact cells, thus detecting both agonists and antagonists. It is homogeneous in that assay reagents are added in sequence and the wells are subsequently analyzed without intervening wash steps. Microplate wells are routinely processed at a rate of 40 wells per minute, requiring a volume of only 2 μl to be sampled from each. This screening approach has recently been extended to identify a high-affinity, selective agonist for the intracellular estrogen-binding G protein–coupled receptor GPR30. With the development of appropriate assay reagents, it may be generally adaptable to a wide range of receptors. The total time required for the assay ranges between 1.5 and 2.5 h. The time required for flow cytometry analysis of a 96-well plate at the end of the procedure is less than 2.5 min. By comparison, manual processing of 96 samples will typically require 40–50 min, and a fast commercial automated sampler processes 96-well plates in less than 15 min, requiring the aspiration of 22 μl per sample for an analysis volume of 2 μl.