EPErika G. Puente

Erika G. Puente

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Erika G. Puente has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In Vitro Assessment of Clevidipine Using the Profilin1 Hypertensive Mouse Model

    by Hamdy H. Hassanain, Mohamed D. H. Hassona, Erika G. Puente, Chengwen Sun, Zeinb A. Abouelnaga, David B. Tulman, Sergio D. Bergese

    Hypertension represents a major risk factor for cardiovascular events, associating with vascular hypertrophy and dysfunction in resistance vessels. Clevidipine is a novel antihypertensive drug working as a selective calcium channel antagonist with an ultra-short half-life that lowers arterial blood pressure by reducing systemic arterial resistance. The aim was to assess the effect of clevidipine on the hypertrophic vessels of profilin1 hypertensive transgenic mice compared to sodium nitroprusside (SNP) and labetalol using wire myograph techniques. The effects of clevidipine, SNP and labetalol on the hypertrophic vessels were studied on mesenteric arterial function from 8 profilin1 hypertrophic mice and eight non-transgenic controls. Our results showed a significant difference between the effects of the three drugs on the hypertrophic mesenteric arteries of transgenic profilin1 mice compared to the non-transgenic controls. The half maximal effective concentration (EC50) of clevidipine, SNP and labetalol in profilin1 mice (1.90 ± 0.05, 0.97 ± 0.07, 2.80 ± 0.05 nM, respectively) were significantly higher than the EC50 in non-transgenic controls (0.91 ± 0.06, 0.32 ± 0.06, 0.80 ± 0.09 nM, respectively). Moreover, the increase in the EC50 for clevidipine (2-fold) to produce the same effect on both normal and hypertrophic arteries was less than that of SNP (3-fold) and labetalol (3.5-fold). Therefore, we concluded clevidipine exhibited the lowest dose shift to relax the hypertrophic vessels compared to SNP and labetalol in the profilin1 hypertrophic animal mouse model.


  • Contributors

    by Young Ahn, Anuja Antony, William G. Austen, Arna Banerjee, Sergio D. Bergese, Arnold Berry, John A. Carter, Jennifer A. Chatburn, Marianna P. Crowley, Paul D. Davis, et al.

  • SNAP II versus BIS VISTA monitor comparison during general anesthesia

    by Candace Hrelec, Erika Puente, Sergio Bergese, Roger Dzwonczyk

    Effectively monitoring the level of consciousness during general anesthesia is clinically beneficial to both the patient and the physician. An electroencephalogram (EEG)-based level-of-consciousness monitor can help minimize intraoperative awareness as well as the effects of over-sedation. In this study, we compared the SNAP II (Stryker Instruments, Kalamazoo, MI USA) and BIS VISTA (Aspect Medical Systems, Newton, MA USA) monitors’ primary metrics (SI and BIS, respectively) in terms of correlation, agreement and responsiveness to return to preoperative baseline in surgical cases involving general anesthesia. With institutional approval and written informed consent, 33 patients received general anesthesia with isoflurane while undergoing abdominal surgery. We attached both the SNAP II and BIS VISTA electrodes to each patient. We collected data from each monitor simultaneously and continuously, beginning just prior to induction and ending after extubation. Each monitor’s level-of-consciousness index is a unit less metric that ranges from 0 to 100, with 100 indicating full consciousness. We performed a Bland–Altman and parameter difference analyses on the data. We calculated the time it took for each monitor to return to preoperative baseline level following cessation of anesthesia. We established an equivalence between the two indices over their entire range for our particular clinical scenario. The indices were correlated (r = 0.736, P < 0.0001, N = 3,706 data point pairs). There was an overall difference between the two indices (median = 16.0, 25th/75th%ile = 10.0/21.1) with BIS lower than SI. A 40-60 BIS range (the typical target range during general anesthesia) was approximately equivalent to a 54–74 SI range. In all 33 subjects, SI reached baseline before BIS at the end of the case (median = 3.3 min, 25th/75th%ile = 1.6 min/8.2 min versus median = 8.9 min, 25th/75th = 3.7 min/14.5 min, P = 0.0200), even though both metrics were equal at the beginning of the case. Although the SI and BIS both can assess a patient’s level of consciousness and are correlated, they are not in agreement with each other numerically and therefore are not interchangeable. It is difficult to assess each monitor’s true responsiveness to acute changes in consciousness level from our study design. The differences between the metrics we observed in this study are most likely due to differences in signal processing methodologies, EEG frequencies employed and signal filtering utilized in the monitors.