EWEnaksha R. Wickremsinhe

Enaksha R. Wickremsinhe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Enaksha R. Wickremsinhe has a total of 51 co-authors. Here are the top co-authors by number of shared publications:

  • Basira G Abdul

    Lilly Research Laboratories, Eli Lilly & Company, Indianapolis, IN, USA

    2 shared publications
  • Bradley L. Ackermann

    Eli Lilly and Company, Indianapolis, Indiana 46285, and Advion BioServices Inc., Ithaca, New York 14850

    2 shared publications
  • Everett J Perkins

    Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, Indiana, USA

    2 shared publications
  • Kenneth J Ruterbories

    Lilly Research Laboratories, Eli Lilly & Company, Indianapolis, IN, USA

    2 shared publications
  • Kenneth J. Ruterbories

    Eli Lilly and Company, Indianapolis, IN, USA

    2 shared publications
  • Naijia H Huang

    Lilly Research Laboratories, Eli Lilly & Company, Indianapolis, IN, USA

    2 shared publications

Latest Publications

  • Open Access

    Standard Venipuncture vs a Capillary Blood Collection Device for the Prospective Determination of Abnormal Liver Chemistry

    by Enaksha Wickremsinhe, Antoniu Fantana, Erwin Berthier, Brook A Quist, Diego Lopez de Castilla, Charles Fix, Kahlil Chan, Jing Shi, Michael G Walker, Jennifer F Kherani, et al.

    Background: Abnormal liver function is a common manifestation of human disease and may also occur in approved and investigational medications as drug-induced liver injury (DILI). Capillary blood collection devices may allow for more frequent and convenient measurement outside of the clinic. Validation of such approaches is lacking. Methods: This prospective, biospecimens collection study evaluated the Tasso+ in patients with abnormal liver tests (NCT05259618). The primary objective was to define the concordance of alanine aminotransferase (ALT) obtained via Tasso+ compared to standard venipuncture. Secondary objectives included measurement of 14 other analytes and patient surveys. At the time of venipuncture, 2 Tasso+ samples were collected: one was centrifuged and shipped, and the other was refrigerated and shipped as whole blood. Results: Thirty-six patients with elevated ALT values were enrolled. In total, 100 venipuncture, 50 Tasso+ centrifuged, and 48 Tasso+ whole blood samples were obtained. Tasso+ centrifuged samples demonstrated concordance correlation coefficients (CCC) of >0.99 for ALT, alkaline phosphatase (ALP), aspartate aminotransferase (AST), and total bilirubin and CCC >0.95 for albumin, chloride, enzymatic creatinine, serum glucose, magnesium, and phosphorus. Tasso+ whole blood showed CCC of >0.99 for AST, bilirubin total, and enzymatic creatinine and CCC >0.95 for ALT, ALP, albumin, magnesium, and phosphorus. Hemolysis was comparable across the 3 sample types, but its impact was reflected in the Tasso+ potassium data. Patient feedback indicated a very favorable patient experience. Conclusions: The capillary blood collection device, Tasso+, showed substantial to almost perfect concordance to standard venipuncture for measurement of abnormal liver function. Studies are ongoing to validate longitudinal sampling outside of the clinic. Clinicaltrials.gov Registration Number: NCT05259618


  • Open Access

    Quantification of Abemaciclib and Metabolites: Evolution of Bioanalytical Methods Supporting a Novel Oncolytic Agent

    by Enaksha R Wickremsinhe, Lisa B Lee

    Aim: Bioanalytical methods undergo many revisions and modifications throughout drug development to meet the objectives of the study and development program. Results: Validated LC–MS/MS methodology ...


  • Bioanalysis and the Oncology Revolution

    by Enaksha R Wickremsinhe, Christopher A James


  • Land O’Lakes Workshop on Microsampling: Enabling Broader Adoption

    by Enaksha R Wickremsinhe, Qin C. Ji, Carol R. Gleason, Melanie Anderson, Brian P. Booth

    The microsampling workshop generated recommendations pertaining to blood sampling site (venous blood versus capillary blood), when to conduct a bridging st


  • Evaluation of Correlation between Bioanalytical Methods

    by Carol R Gleason, Qin C Ji, Enaksha R Wickremsinhe

    Bioanalytical methods evolve throughout clinical development timelines, resulting in the need for establishing equivalency or correlation between different methods to enable comparison of data acro...


    • 1 March 2015
      • Vol. 54  (2) , 139-44

    Using dried blood spot sampling to improve data quality and reduce animal use in mouse pharmacokinetic studies.

    by Enaksha R Wickremsinhe, Everett J Perkins

    Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 μL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal-often to a single collection per mouse-thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 μL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study.


  • Open Access

    Preclinical Absorption, Distribution, Metabolism, and Excretion of an Oral Amide Prodrug of Gemcitabine Designed to Deliver Prolonged Systemic Exposure

    by Enaksha Wickremsinhe, Jingqi Bao, Richard Smith, Richard Burton, Shannon Dow, Everett Perkins

    Gemcitabine is an intravenously administered nucleoside analog chemotherapeutic agent. The ability to deliver this agent as an oral drug would allow greater flexibility of administration and patient convenience; however, attempts have been fraught with high first-pass metabolism and potential intestinal toxicity. Alternatively, an amide prodrug of gemcitabine (LY2334737) was discovered, which is able to avoid the extensive first-pass metabolism that occurs following administration of gemcitabine. Preclinical in vitro and in vivo experiments were conducted to evaluate the hydrolysis and pharmacokinetics of LY2334737 and its downstream metabolites. In mice, rats, and dogs, the prodrug is absorbed largely intact across the intestinal epithelium and delivers LY2334737 to systemic circulation. The hydrolysis of LY2334737 is relatively slow, resulting in sustained release of gemcitabine in vivo. In vitro experiments identified carboxylesterase 2 (CES2) as a major enzyme involved in the hydrolysis of LY2334737, but with relatively low intrinsic clearance. Following hydrolysis of the prodrug, gemcitabine is cleared predominantly via the formation of its inactive metabolite dFdU. Both biliary and renal excretion was responsible for the elimination of LY2334737 and its metabolites in both mice and dogs.


  • Preclinical Bridging Studies: Understanding Dried Blood Spot and Plasma Exposure Profiles

    by Enaksha R Wickremsinhe, Naijia H Huang, Basira G Abdul, Kirk Knotts, Kenneth J Ruterbories, Jason R Manro

    Understanding the distribution of the analyte between the cellular and noncellular (plasma) components of the blood is important, especially in situations where dried blood spot (DBS) data need to be compared with plasma data, or vice versa. Pearson's coefficient, Lin's coefficient and the Bland-Altman analysis are appropriate to evaluate the concordance between DBS and plasma data from bridging studies. Percent recovery plots generated using the ex vivo blood:plasma ratio and the regression equations demonstrate the best approach for predicting plasma concentrations from DBS. Statistical analysis of bridging study data is needed to characterize the relationship or concordance between blood (DBS) and plasma. The outcomes also provide guidance on selecting the most appropriate approach to transform DBS data to plasma, or vice versa. However, the biological and statistical evidence must be weighed together when deciding if DBS is suitable for preclinical and/or clinical development.


  • Dried Blood Spot Sampling: Coupling Bioanalytical Feasibility, Blood–Plasma Partitioning and Transferability toIn VivoPreclinical Studies

    by Enaksha R Wickremsinhe, Basira G Abdul, Naijia H Huang, John W Richard, Jennifer L Hanes, Kenneth J Ruterbories, Everett J Perkins, Ajai K Chaudhary

    The adoption of dried blood spot (DBS) sampling and analysis to support drug discovery and development requires the understanding of its bioanalytical feasibility as well as the distribution of the analyte in blood. Demonstrated the feasibility of adopting DBS for four test analytes representing diverse physico-chemical as well as pharmacokinetic parameters. The key findings include the use of a single extraction procedure across all four analytes, assay range of 1 to 5000 ng/ml, stability in whole blood as well as on-card, and the non-impact of blood volume. In vivo data were used to calculate the blood-to-plasma ratio (using both AUC and average of individual time points), which was then used to predict plasma concentration from DBS data. The predicted data showed an excellent correlation with actual plasma data. Transition from plasma to DBS can be supported for preclinical studies by conducting a few well-defined bioanalytical experiments followed by an in vivo bridging study. Blood:plasma ratio derived from the bridging study can be used to predict plasma concentrations from DBS data.