Kyosuke Sakaue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kyosuke Sakaue has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Yasutoshi Shimizu
Water and Lifestyle Research Laboratory, 31-3, Munakata, Fukuoka 811-4141, Japan
2 shared publications - Cheng-Li Cheng
National Taiwan University of Science and Technology
1 shared publication Kanaka Toyosada
Food Waste Processing System Association
1 shared publication- Kanako Toyosada
ESG Promotion Department, TOTO LTD, 2-1-1, Nakashima, Kokurakita-ku, Kitakyushu 802-8601, Japan
1 shared publication - Kanako Toyosada
Department of Environmental Science, International College of Arts and Science, Fukuoka Women’s University, 1-1-1, Kasumigaoka, Higashi-ku, Fukuoka City 813-8529, Japan
1 shared publication Kaori Kitaguchi
Food Waste Processing System Association
1 shared publication
Latest Publications
- Open Access
Analysis of Pneumatic Pressure Vibration Affected by Connecting WCs and Discharge Load Types
In the design of a drainage system, allowable drainage flow quantity (drainage capability) is defined for each pipe diameter in order to prevent seal water from breaking. In Japan, SHASE-S 218 (Heating, Air-Conditioning, and Sanitary Standard) stipulates the evaluation standard for drainage capability. Regardless of the presence or absence of connection of the traps, there are two types of test criteria. One is that pressure in the pipe should fall within ±400 Pa, and the other is that the seal loss should be less than 25 mm. Nevertheless, recent studies revealed that the connecting of traps attenuates pneumatic pressure in pipes and causes a tendency of the power spectrum distribution to change. This phenomenon may be attributable to the fact that seal water vibration is a response phenomenon to pneumatic pressure vibration, and that they affect each other. In view of this, we conducted discharge experiments based on SHASE-S 218 with and without traps (including water-saving toilet bowl (hereinafter, referred to as “WC”) using a real size drainage experimental system to clarify how the connection of WC might influence pneumatic pressure. We revealed that as the number of toilets connected to the drainage system increases, the pneumatic pressure and seal water loss decrease.
Open AccessAnalysis of Pneumatic Pressure Vibration Affected by Connecting WCs and Discharge Load Types
In the design of a drainage system, allowable drainage flow quantity (drainage capability) is defined for each pipe diameter in order to prevent seal water from breaking. In Japan, SHASE-S 218 (Heating, Air-Conditioning, and Sanitary Standard) stipulates the evaluation standard for drainage capability. Regardless of the presence or absence of connection of the traps, there are two types of test criteria. One is that pressure in the pipe should fall within ±400 Pa, and the other is that the seal loss should be less than 25 mm. Nevertheless, recent studies revealed that the connecting of traps attenuates pneumatic pressure in pipes and causes a tendency of the power spectrum distribution to change. This phenomenon may be attributable to the fact that seal water vibration is a response phenomenon to pneumatic pressure vibration, and that they affect each other. In view of this, we conducted discharge experiments based on SHASE-S 218 with and without traps (including water-saving toilet bowl (hereinafter, referred to as “WC”) using a real size drainage experimental system to clarify how the connection of WC might influence pneumatic pressure. We revealed that as the number of toilets connected to the drainage system increases, the pneumatic pressure and seal water loss decrease.
- Open Access
Comparison of the Physical Properties of Showers that the Satisfaction of Shower Feeling among Users in Three Asian Countries
The purpose of this study was to construct a scheme that makes it possible to compare the relationship between water usage, satisfaction, and physical properties in three countries. The physical properties of the shower were measured using physical properties testing apparatus of water-saving standard or scheme for showerheads issued in several water-saving countries and data for users satisfaction evaluation was acquired through bathing experiments. In this paper, we analyzed the result from Taiwanese and Vietnamese individuals to compare them to of Japanese subjects analyzed in the previous study. We compared the physical properties of showers assessed low in satisfaction by Taiwanese, Vietnamese and Japanese subjects. It was assumed that spray pattern tends to decrease satisfaction when the water volume ratio within 100 mm and 150 mm of a measuring device is located a 450 mm distance from the showerhead is low, and that, because all three countries showed the same value, it was imagined that there were no differences in the water volume ratio of high-satisfaction showerheads among three countries. On the other hand, the values of Spray Force-per-Hole, Temperature Drop, and Spray Angle were different among three countries. We speculated that these differences are affected respectively by ethnic differences in pain tolerance, thermoregulatory response and bathing habit.
Open AccessComparison of the Physical Properties of Showers that the Satisfaction of Shower Feeling among Users in Three Asian Countries
The purpose of this study was to construct a scheme that makes it possible to compare the relationship between water usage, satisfaction, and physical properties in three countries. The physical properties of the shower were measured using physical properties testing apparatus of water-saving standard or scheme for showerheads issued in several water-saving countries and data for users satisfaction evaluation was acquired through bathing experiments. In this paper, we analyzed the result from Taiwanese and Vietnamese individuals to compare them to of Japanese subjects analyzed in the previous study. We compared the physical properties of showers assessed low in satisfaction by Taiwanese, Vietnamese and Japanese subjects. It was assumed that spray pattern tends to decrease satisfaction when the water volume ratio within 100 mm and 150 mm of a measuring device is located a 450 mm distance from the showerhead is low, and that, because all three countries showed the same value, it was imagined that there were no differences in the water volume ratio of high-satisfaction showerheads among three countries. On the other hand, the values of Spray Force-per-Hole, Temperature Drop, and Spray Angle were different among three countries. We speculated that these differences are affected respectively by ethnic differences in pain tolerance, thermoregulatory response and bathing habit.
- Open Access
Creation of Carbon Credits by Water Saving
Until now, as a way of reducing greenhouse gas emissions from Japanese homes, the emphasis has been on reduction of energy consumption for air-conditioning and lighting. In recent years, there has been progress in CO2 emission reduction through research into the water-saving performance of bathroom fixtures such as toilets and showers. Simulations have shown that CO2 emissions associated with water consumption in Japanese homes can be reduced by 25% (1% of Japan’s total CO2 emissions) by 2020 through the adoption of the use of water-saving fixtures. In response to this finding, a program to promote the replacement of current fixtures with water-saving toilet bowls and thermally insulated bathtubs has been added to the Government of Japan’s energy-saving policy. Furthermore, CO2 emission reduction through widespread use of water-saving fixtures has been adopted by the domestic credit system promoted by the Government of Japan as a way of achieving CO2 emission-reduction targets; application of this credit system has also begun. As part of a bilateral offset credit mechanism promoted by the Government of Japan, research to evaluate the CO2 reduction potential of the adoption of water-saving fixtures has been done in the city of Dalian, in China.
Open AccessCreation of Carbon Credits by Water Saving
Until now, as a way of reducing greenhouse gas emissions from Japanese homes, the emphasis has been on reduction of energy consumption for air-conditioning and lighting. In recent years, there has been progress in CO2 emission reduction through research into the water-saving performance of bathroom fixtures such as toilets and showers. Simulations have shown that CO2 emissions associated with water consumption in Japanese homes can be reduced by 25% (1% of Japan’s total CO2 emissions) by 2020 through the adoption of the use of water-saving fixtures. In response to this finding, a program to promote the replacement of current fixtures with water-saving toilet bowls and thermally insulated bathtubs has been added to the Government of Japan’s energy-saving policy. Furthermore, CO2 emission reduction through widespread use of water-saving fixtures has been adopted by the domestic credit system promoted by the Government of Japan as a way of achieving CO2 emission-reduction targets; application of this credit system has also begun. As part of a bilateral offset credit mechanism promoted by the Government of Japan, research to evaluate the CO2 reduction potential of the adoption of water-saving fixtures has been done in the city of Dalian, in China.