Stéphane Troesch
Research Subjects
Stéphane Troesch has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Dirk Esser
SINT (Society of Natural and Technical Engineering), Chef Lieu, 73370 La Chapelle du Mont du Chat, France
2 shared publications - Pascal Molle
Inrae, REVERSAAL Research Unit, Villeurbanne, France
2 shared publications D Rousseau
1 shared publicationD. Esser
Société d'Ingénierie Nature & Technique, Chef-lieu, 73370 La Chapelle du Mont du Chat, France
1 shared publication- Daniel Meyer
IRSTEA Lyon (National Research Institute of Science and Technology for Environment and Agriculture, former CEMAGREF), 5 rue de la Doua, CS70077, Villeurbanne 69626, France
1 shared publication F. Salma
Epur Nature – Syntea, 12 rue Toussaint Fléchaire, Caumont-sur-Durance, 84 510, France
1 shared publication
Latest Publications
- 1 January 2015
- Vol. 80 (1) , 131-6
CAN A SINGLE STAGE HYBRID CONSTRUCTED WETLAND ACHIEVE GOOD TOTAL NITROGEN REMOVAL?
- 1 January 2015
- Vol. 80 (1) , 131-6
CAN A SINGLE STAGE HYBRID CONSTRUCTED WETLAND ACHIEVE GOOD TOTAL NITROGEN REMOVAL?
- 1 September 2014
- Published by IWA Publishing in Water Practice & Technology
- Vol. 9 (3) , 430-439
Constructed wetlands for the treatment of raw wastewater: the French experience
Vertical flow constructed wetlands for small communities (<5,000 population equivalent) have been successfully developed in France since the 1990s (currently about 3'000 plants are in operation). This paper summarizes the results and efficiencies of 70 plants designed and built by Epur Nature or SINT. The results show clearly that the design performs well for organic matter removal and nitrification and makes sludge management easy. Therefore if well designed, such systems can achieve an outlet quality of BOD5 < 20 mg/L, chemical oxygen demand <90 mg/L, suspended solids <30 mg/L and TKN < 15 mg/L. In addition, some new configurations involving a French vertical first stage fed with raw sewage, patented by Epur Nature, are presented as an aid to reduce the global footprint.
- 1 September 2014
- Published by IWA Publishing in Water Practice & Technology
- Vol. 9 (3) , 430-439
Constructed wetlands for the treatment of raw wastewater: the French experience
Vertical flow constructed wetlands for small communities (<5,000 population equivalent) have been successfully developed in France since the 1990s (currently about 3'000 plants are in operation). This paper summarizes the results and efficiencies of 70 plants designed and built by Epur Nature or SINT. The results show clearly that the design performs well for organic matter removal and nitrification and makes sludge management easy. Therefore if well designed, such systems can achieve an outlet quality of BOD5 < 20 mg/L, chemical oxygen demand <90 mg/L, suspended solids <30 mg/L and TKN < 15 mg/L. In addition, some new configurations involving a French vertical first stage fed with raw sewage, patented by Epur Nature, are presented as an aid to reduce the global footprint.
- Open Access
Constructed Wetlands for Combined Sewer Overflow Treatment—Comparison of German, French and Italian Approaches
Combined sewer systems are designed to transport stormwater surface run off in addition to the dry weather flows up to defined limits. In most European countries, hydraulic loads greater than the design flow are discharged directly into receiving water bodies, with minimal treatment (screening, sedimentation), or with no treatment at all. One feasible solution to prevent receiving waters from strong negative impacts seems to be the application of vertical flow constructed wetlands. In Germany, first attempts to use this ecological technology were recognized in early 1990s. Since then, further development continued until a high level of treatment performance was reached. During recent years the national “state-of-the-art” (defined in 2005) was adapted in other European countries, including France and Italy. Against the background of differing national requirements in combined sewer system design, substantial developmental steps were taken. The use of coarser filter media in combination with alternating loadings of separated filter beds allows direct feedings with untreated combined runoff. Permanent water storage in deep layers of the wetland improves the system’s robustness against extended dry periods, but contains operational risks. Besides similar functions (but different designs and layouts), correct dimensioning of all approaches suffers from uncertainties in long-term rainfall predictions as well as inside sewer system simulation tools.
Open AccessConstructed Wetlands for Combined Sewer Overflow Treatment—Comparison of German, French and Italian Approaches
Combined sewer systems are designed to transport stormwater surface run off in addition to the dry weather flows up to defined limits. In most European countries, hydraulic loads greater than the design flow are discharged directly into receiving water bodies, with minimal treatment (screening, sedimentation), or with no treatment at all. One feasible solution to prevent receiving waters from strong negative impacts seems to be the application of vertical flow constructed wetlands. In Germany, first attempts to use this ecological technology were recognized in early 1990s. Since then, further development continued until a high level of treatment performance was reached. During recent years the national “state-of-the-art” (defined in 2005) was adapted in other European countries, including France and Italy. Against the background of differing national requirements in combined sewer system design, substantial developmental steps were taken. The use of coarser filter media in combination with alternating loadings of separated filter beds allows direct feedings with untreated combined runoff. Permanent water storage in deep layers of the wetland improves the system’s robustness against extended dry periods, but contains operational risks. Besides similar functions (but different designs and layouts), correct dimensioning of all approaches suffers from uncertainties in long-term rainfall predictions as well as inside sewer system simulation tools.