Roger Jagdish Narayan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Roger Jagdish Narayan has a total of 195 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandr Ovsianikov
Institute of Materials Science and Technology, Technische Universität Wien, Vienna, Austria
5 shared publications Chunming Jin
Joint Department of Biomedical Engineering, University of North Carolina, Chapel Hill, NC 27599, USA
5 shared publications- Nancy A. Monteiro-Riviere
Nanotechnology Innovation Center of Kansas State, Kansas State University, Manhattan, KS, USA
5 shared publications Peter L. Goering
Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, USA
5 shared publications- Jagdish Narayan
Department of Materials Science and Engineering, North Carolina State University, Raleigh, USA
4 shared publications Shaun D. Gittard
Joint Department of Biomedical Engineering, University of North Carolina, and North Carolina State University Chapel Hill, Raleigh, NC 27599‐7115, USA
4 shared publications
Latest Publications
- 1 September 2017
- Published by Springer Nature in MRS Communications
- Vol. 7 (3) , 416-426
Gelatin-based hydrogels for biomedical applications
- 1 September 2017
- Published by Springer Nature in MRS Communications
- Vol. 7 (3) , 416-426
Gelatin-based hydrogels for biomedical applications
- 12 May 2016
- Published by Springer Nature in JOM
- Vol. 68 (6) , 1672-1678
Biological Response of Human Bone Marrow-Derived Mesenchymal Stem Cells to Commercial Tantalum Coatings with Microscale and Nanoscale Surface Topographies
- 12 May 2016
- Published by Springer Nature in JOM
- Vol. 68 (6) , 1672-1678
Biological Response of Human Bone Marrow-Derived Mesenchymal Stem Cells to Commercial Tantalum Coatings with Microscale and Nanoscale Surface Topographies
- 16 February 2016
- Published by Springer Nature in JOM
- Vol. 68 (4) , 1128-1133
Use of Drawing Lithography-Fabricated Polyglycolic Acid Microneedles for Transdermal Delivery of Itraconazole to a Human Basal Cell Carcinoma Model Regenerated on Mice
Itraconazole is a triazole agent that is routinely used for treatment of nail infections and other fungal infections. Recent studies indicate that itraconazole can also inhibit the growth of basal cell carcinoma (BCC) through suppression of the Sonic Hedgehog (SHH) signaling pathway. In this study, polyglycolic acid microneedle arrays and stainless steel microneedle arrays were used for transdermal delivery of itraconazole to a human BCC model which was regenerated on mice. One-by-four arrays of 642-μm-long polyglycolic acid microneedles with sharp tips were prepared using injection molding and drawing lithography. Arrays of 85 stainless steel 800-μm-tall microneedles attached to syringes were obtained for comparison purposes. Skin grafts containing devitalized split-thickness human dermis that had been seeded with human keratinocytes transduced to express human SHH protein were sutured to the skin of immunodeficient mice. Mice with this human BCC model were treated daily for 2 weeks with itraconazole dissolved in 60% dimethylsulfoxane and 40% polyethylene glycol-400 solution; transdermal administration of the itraconazole solution was facilitated by either four 1 × 4 polyglycolic acid microneedle arrays or stainless steel microneedle arrays. The epidermal tissues treated with polyglycolic acid microneedles or stainless steel microneedles were markedly thinner than that of the control (untreated) graft tissue. These preliminary results indicate that microneedles may be used to facilitate transdermal delivery of itraconazole for localized treatment of BCC.
- 16 February 2016
- Published by Springer Nature in JOM
- Vol. 68 (4) , 1128-1133
Use of Drawing Lithography-Fabricated Polyglycolic Acid Microneedles for Transdermal Delivery of Itraconazole to a Human Basal Cell Carcinoma Model Regenerated on Mice
Itraconazole is a triazole agent that is routinely used for treatment of nail infections and other fungal infections. Recent studies indicate that itraconazole can also inhibit the growth of basal cell carcinoma (BCC) through suppression of the Sonic Hedgehog (SHH) signaling pathway. In this study, polyglycolic acid microneedle arrays and stainless steel microneedle arrays were used for transdermal delivery of itraconazole to a human BCC model which was regenerated on mice. One-by-four arrays of 642-μm-long polyglycolic acid microneedles with sharp tips were prepared using injection molding and drawing lithography. Arrays of 85 stainless steel 800-μm-tall microneedles attached to syringes were obtained for comparison purposes. Skin grafts containing devitalized split-thickness human dermis that had been seeded with human keratinocytes transduced to express human SHH protein were sutured to the skin of immunodeficient mice. Mice with this human BCC model were treated daily for 2 weeks with itraconazole dissolved in 60% dimethylsulfoxane and 40% polyethylene glycol-400 solution; transdermal administration of the itraconazole solution was facilitated by either four 1 × 4 polyglycolic acid microneedle arrays or stainless steel microneedle arrays. The epidermal tissues treated with polyglycolic acid microneedles or stainless steel microneedles were markedly thinner than that of the control (untreated) graft tissue. These preliminary results indicate that microneedles may be used to facilitate transdermal delivery of itraconazole for localized treatment of BCC.
- Open Access
- 31 January 2016
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 2 (1) , 72
Microstereolithography-fabricated microneedles for fluid sampling of histamine-contaminated tuna
A custom-designed microneedle sampling system was prepared using dynamic mask microstereolithography; this sampling system was used for determination of histamine content in fresh, histamine-spiked, and spoiled tuna flesh. Lateral flow (test strip) assays were successfully utilized in the microneedle sampling system to assess histamine content. Good agreement was noted between data obtained from the microneedle sampling system and a commercially available histamine detection kit. A discrepancy was noted in the results from the microneedle sampling system and the commercially available histamine detection kit at low (negative) levels of histamine. There was an improvement in the agreement between the microneedle sampling system and the commercially available histamine detection kit at higher histamine levels. The results, which showed an improvement in the test duration and the amount of reagent needed for histamine detection, indicate the promise of printed microneedle sampling systems for histamine detection in seafood samples and other types of food testing.
- 31 January 2016
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 2 (1) , 72
Open AccessMicrostereolithography-fabricated microneedles for fluid sampling of histamine-contaminated tuna
A custom-designed microneedle sampling system was prepared using dynamic mask microstereolithography; this sampling system was used for determination of histamine content in fresh, histamine-spiked, and spoiled tuna flesh. Lateral flow (test strip) assays were successfully utilized in the microneedle sampling system to assess histamine content. Good agreement was noted between data obtained from the microneedle sampling system and a commercially available histamine detection kit. A discrepancy was noted in the results from the microneedle sampling system and the commercially available histamine detection kit at low (negative) levels of histamine. There was an improvement in the agreement between the microneedle sampling system and the commercially available histamine detection kit at higher histamine levels. The results, which showed an improvement in the test duration and the amount of reagent needed for histamine detection, indicate the promise of printed microneedle sampling systems for histamine detection in seafood samples and other types of food testing.
- 17 December 2014
- Published by Wiley in Advanced Healthcare Materials
- Vol. 4 (5) , 739-747
Laser 3D Printing with Sub‐Microscale Resolution of Porous Elastomeric Scaffolds for Supporting Human Bone Stem Cells
A reproducible method is needed to fabricate 3D scaffold constructs that results in periodic and uniform structures with precise control at sub‐micrometer and micrometer length scales. In this study, fabrication of scaffolds by two‐photon polymerization (2PP) of a biodegradable urethane and acrylate‐based photoelastomer is demonstrated. This material supports 2PP processing with sub‐micrometer spatial resolution. The high photoreactivity of the biophotoelastomer permits 2PP processing at a scanning speed of 1000 mm s−1, facilitating rapid fabrication of relatively large structures (>5 mm3). These structures are custom printed for in vitro assay screening in 96‐well plates and are sufficiently flexible to enable facile handling and transplantation. These results indicate that stable scaffolds with porosities of greater than 60% can be produced using 2PP. Human bone marrow stromal cells grown on 3D scaffolds exhibit increased growth and proliferation compared to smooth 2D scaffold controls. 3D scaffolds adsorb larger amounts of protein than smooth 2D scaffolds due to their larger surface area; the scaffolds also allow cells to attach in multiple planes and to completely infiltrate the porous scaffolds. The flexible photoelastomer material is biocompatible in vitro and is associated with facile handling, making it a viable candidate for further study of complex 3D‐printed scaffolds.
- 17 December 2014
- Published by Wiley in Advanced Healthcare Materials
- Vol. 4 (5) , 739-747
Laser 3D Printing with Sub‐Microscale Resolution of Porous Elastomeric Scaffolds for Supporting Human Bone Stem Cells
A reproducible method is needed to fabricate 3D scaffold constructs that results in periodic and uniform structures with precise control at sub‐micrometer and micrometer length scales. In this study, fabrication of scaffolds by two‐photon polymerization (2PP) of a biodegradable urethane and acrylate‐based photoelastomer is demonstrated. This material supports 2PP processing with sub‐micrometer spatial resolution. The high photoreactivity of the biophotoelastomer permits 2PP processing at a scanning speed of 1000 mm s−1, facilitating rapid fabrication of relatively large structures (>5 mm3). These structures are custom printed for in vitro assay screening in 96‐well plates and are sufficiently flexible to enable facile handling and transplantation. These results indicate that stable scaffolds with porosities of greater than 60% can be produced using 2PP. Human bone marrow stromal cells grown on 3D scaffolds exhibit increased growth and proliferation compared to smooth 2D scaffold controls. 3D scaffolds adsorb larger amounts of protein than smooth 2D scaffolds due to their larger surface area; the scaffolds also allow cells to attach in multiple planes and to completely infiltrate the porous scaffolds. The flexible photoelastomer material is biocompatible in vitro and is associated with facile handling, making it a viable candidate for further study of complex 3D‐printed scaffolds.
- 26 March 2014
- Published by Springer Nature in JOM
- Vol. 66 (4) , 588-589
Biological, Electronic, and Functional Thin Films
- 26 March 2014
- Published by Springer Nature in JOM
- Vol. 66 (4) , 588-589
Biological, Electronic, and Functional Thin Films
- 21 March 2014
- Published by Springer Nature in JOM
- Vol. 66 (4) , 649-653
Growth of Zircone on Nanoporous Alumina Using Molecular Layer Deposition
- 21 March 2014
- Published by Springer Nature in JOM
- Vol. 66 (4) , 649-653
Growth of Zircone on Nanoporous Alumina Using Molecular Layer Deposition
- 21 December 2013
- Published by Wiley in Advanced Healthcare Materials
- Vol. 3 (6) , 876-881
Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+
The determination of electrolytes is invaluable for point of care diagnostic applications. An ion selective transdermal microneedle sensor is demonstrated for potassium by integrating a hollow microneedle with a microfluidic chip to extract fluid through a channel towards a downstream solid‐state ion‐selective‐electrode (ISE). 3D porous carbon and 3D porous graphene electrodes, made via interference lithography, are compared as solid‐state transducers for ISE's and evaluated for electrochemical performance, stability, and selectivity. The porous carbon K+ ISE's show better performance than the porous graphene K+ ISE's, capable of measuring potassium across normal physiological concentrations in the presence of interfering ions with greater stability. This new microfluidic/microneedle platform shows promise for medical applications.
- 21 December 2013
- Published by Wiley in Advanced Healthcare Materials
- Vol. 3 (6) , 876-881
Microneedle‐Based Transdermal Sensor for On‐Chip Potentiometric Determination of K+
The determination of electrolytes is invaluable for point of care diagnostic applications. An ion selective transdermal microneedle sensor is demonstrated for potassium by integrating a hollow microneedle with a microfluidic chip to extract fluid through a channel towards a downstream solid‐state ion‐selective‐electrode (ISE). 3D porous carbon and 3D porous graphene electrodes, made via interference lithography, are compared as solid‐state transducers for ISE's and evaluated for electrochemical performance, stability, and selectivity. The porous carbon K+ ISE's show better performance than the porous graphene K+ ISE's, capable of measuring potassium across normal physiological concentrations in the presence of interfering ions with greater stability. This new microfluidic/microneedle platform shows promise for medical applications.
- Top Cited Papers
- 4 December 2013
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 25 (3) , 845-856
Stereolithography in tissue engineering
Several recent research efforts have focused on use of computer-aided additive fabrication technologies, commonly referred to as additive manufacturing, rapid prototyping, solid freeform fabrication, or three-dimensional printing technologies, to create structures for tissue engineering. For example, scaffolds for tissue engineering may be processed using rapid prototyping technologies, which serve as matrices for cell ingrowth, vascularization, as well as transport of nutrients and waste. Stereolithography is a photopolymerization-based rapid prototyping technology that involves computer-driven and spatially controlled irradiation of liquid resin. This technology enables structures with precise microscale features to be prepared directly from a computer model. In this review, use of stereolithography for processing trimethylene carbonate, polycaprolactone, and poly(d,l-lactide) poly(propylene fumarate)-based materials is considered. In addition, incorporation of bioceramic fillers for fabrication of bioceramic scaffolds is reviewed. Use of stereolithography for processing of patient-specific implantable scaffolds is also discussed. In addition, use of photopolymerization-based rapid prototyping technology, known as two-photon polymerization, for production of tissue engineering scaffolds with smaller features than conventional stereolithography technology is considered.
- 4 December 2013
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 25 (3) , 845-856
Top Cited PapersStereolithography in tissue engineering
Several recent research efforts have focused on use of computer-aided additive fabrication technologies, commonly referred to as additive manufacturing, rapid prototyping, solid freeform fabrication, or three-dimensional printing technologies, to create structures for tissue engineering. For example, scaffolds for tissue engineering may be processed using rapid prototyping technologies, which serve as matrices for cell ingrowth, vascularization, as well as transport of nutrients and waste. Stereolithography is a photopolymerization-based rapid prototyping technology that involves computer-driven and spatially controlled irradiation of liquid resin. This technology enables structures with precise microscale features to be prepared directly from a computer model. In this review, use of stereolithography for processing trimethylene carbonate, polycaprolactone, and poly(d,l-lactide) poly(propylene fumarate)-based materials is considered. In addition, incorporation of bioceramic fillers for fabrication of bioceramic scaffolds is reviewed. Use of stereolithography for processing of patient-specific implantable scaffolds is also discussed. In addition, use of photopolymerization-based rapid prototyping technology, known as two-photon polymerization, for production of tissue engineering scaffolds with smaller features than conventional stereolithography technology is considered.