Norman J. Dovichi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Norman J. Dovichi has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
Jane A. Dickerson
Department of Chemistry, University of Washington, Seattle WA, USA
8 shared publicationsShen Hu
Department of Chemistry, University of Washington, Seattle, WA, USA
8 shared publicationsLauren M. Ramsay
Department of Chemistry, University of Washington, Seattle WA, USA
7 shared publications- Kristian E. Swearingen
Institute for Systems Biology, Seattle, Washington, United States of America
6 shared publications Roza Wojcik
6 shared publications- Emily H. Turner
Department of Genome Sciences, University of Washington, Seattle, WA 98195, USA
3 shared publications
Latest Publications
- 10 October 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1218 (15) , 2007-2011
A replaceable microreactor for on-line protein digestion in a two-dimensional capillary electrophoresis system with tandem mass spectrometry detection
- 10 October 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1218 (15) , 2007-2011
A replaceable microreactor for on-line protein digestion in a two-dimensional capillary electrophoresis system with tandem mass spectrometry detection
- 27 July 2010
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 24 (17) , 2554-2560
Simplified capillary electrophoresis nanospray sheath‐flow interface for high efficiency and sensitive peptide analysis
We report a simple nanospray sheath‐flow interface for capillary electrophoresis. This interface relies on electrokinetic flow to drive both the separation and the electrospray; no mechanical pump is used for the sheath flow. This system was interfaced with an LCQ mass spectrometer. The best results were observed with a 2‐µm diameter emitter tip and a 1‐mm spacing between the separation capillary tip and the emitter tip. Under these conditions, mass detection limits (3 σ ) of 100 amol were obtained for insulin receptor fragment 1142‐1153. The separation efficiency exceeded 200,000 plates for this compound. The relative standard deviation generated during continual infusion of a 50 µM solution of angiotensin II was 2% for the total ion count and 3% for the extracted ion count over a 40‐min period. Finally, the interface was also demonstrated for negative ion mode. Copyright © 2010 John Wiley & Sons, Ltd.
- 27 July 2010
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 24 (17) , 2554-2560
Simplified capillary electrophoresis nanospray sheath‐flow interface for high efficiency and sensitive peptide analysis
We report a simple nanospray sheath‐flow interface for capillary electrophoresis. This interface relies on electrokinetic flow to drive both the separation and the electrospray; no mechanical pump is used for the sheath flow. This system was interfaced with an LCQ mass spectrometer. The best results were observed with a 2‐µm diameter emitter tip and a 1‐mm spacing between the separation capillary tip and the emitter tip. Under these conditions, mass detection limits (3 σ ) of 100 amol were obtained for insulin receptor fragment 1142‐1153. The separation efficiency exceeded 200,000 plates for this compound. The relative standard deviation generated during continual infusion of a 50 µM solution of angiotensin II was 2% for the total ion count and 3% for the extracted ion count over a 40‐min period. Finally, the interface was also demonstrated for negative ion mode. Copyright © 2010 John Wiley & Sons, Ltd.
- 23 July 2010
- Published by Wiley in Electrophoresis
- Vol. 31 (15) , 2650-2654
Two‐dimensional capillary electrophoresis: Capillary isoelectric focusing and capillary zone electrophoresis with laser‐induced fluorescence detection
CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2‐D separation method for proteins. In this method, two capillaries are joined through a buffer‐filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo P503, which preserves the isoelectric point of the labeled protein. The labeled proteins were mixed with ampholytes and injected into the first‐dimension capillary. A focusing step was performed with the injection end of the capillary at high pH and the interface at low pH. To mobilize components, the interface was filled with a high pH buffer, which was compatible with the second‐dimension separation. A fraction was transferred to the second‐dimension capillary for separation. The process of fraction transfer and second dimension separation was repeated two dozen times. The separation produced a spot capacity of 125.
- 23 July 2010
- Published by Wiley in Electrophoresis
- Vol. 31 (15) , 2650-2654
Two‐dimensional capillary electrophoresis: Capillary isoelectric focusing and capillary zone electrophoresis with laser‐induced fluorescence detection
CIEF and CZE are coupled with LIF detection to create an ultrasensitive 2‐D separation method for proteins. In this method, two capillaries are joined through a buffer‐filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo P503, which preserves the isoelectric point of the labeled protein. The labeled proteins were mixed with ampholytes and injected into the first‐dimension capillary. A focusing step was performed with the injection end of the capillary at high pH and the interface at low pH. To mobilize components, the interface was filled with a high pH buffer, which was compatible with the second‐dimension separation. A fraction was transferred to the second‐dimension capillary for separation. The process of fraction transfer and second dimension separation was repeated two dozen times. The separation produced a spot capacity of 125.
- 16 June 2010
- Published by Wiley in Electrophoresis
- Vol. 31 (14) , 2461-2464
Capillary sieving electrophoresis and micellar electrokinetic capillary chromatography produce highly correlated separation of tryptic digests
We perform 2‐D capillary electrophoresis on fluorescently labeled proteins and peptides. Capillary sieving electrophoresis (CSE) was performed in the first dimension and MEKC was performed in the second. A cellular homogenate was labeled with the fluorogenic reagent FQ and separated using the system. This homogenate generated a pair of ridges; the first had essentially constant migration time in the CSE dimension, while the second had essentially constant migration time in the MEKC dimension. In addition, a few spots were scattered through the electropherogram. The same homogenate was digested using trypsin, and then labeled and subjected to the 2‐D separation. In this case, the two ridges observed from the original 2‐D separation disappeared and were replaced by a set of spots that fell along the diagonal. Those spots were identified using a local‐maximum algorithm and each was fit using a 2‐D Gaussian surface by an unsupervised nonlinear least squares regression algorithm. The migration times of the tryptic digest components were highly correlated (r =0.862). When the slowest migrating components were eliminated from the analysis, the correlation coefficient improved to r =0.956.
- 16 June 2010
- Published by Wiley in Electrophoresis
- Vol. 31 (14) , 2461-2464
Capillary sieving electrophoresis and micellar electrokinetic capillary chromatography produce highly correlated separation of tryptic digests
We perform 2‐D capillary electrophoresis on fluorescently labeled proteins and peptides. Capillary sieving electrophoresis (CSE) was performed in the first dimension and MEKC was performed in the second. A cellular homogenate was labeled with the fluorogenic reagent FQ and separated using the system. This homogenate generated a pair of ridges; the first had essentially constant migration time in the CSE dimension, while the second had essentially constant migration time in the MEKC dimension. In addition, a few spots were scattered through the electropherogram. The same homogenate was digested using trypsin, and then labeled and subjected to the 2‐D separation. In this case, the two ridges observed from the original 2‐D separation disappeared and were replaced by a set of spots that fell along the diagonal. Those spots were identified using a local‐maximum algorithm and each was fit using a 2‐D Gaussian surface by an unsupervised nonlinear least squares regression algorithm. The migration times of the tryptic digest components were highly correlated (r =0.862). When the slowest migrating components were eliminated from the analysis, the correlation coefficient improved to r =0.956.
- 25 March 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 397 (8) , 3305-3310
Capillary array isoelectric focusing with laser-induced fluorescence detection: milli-pH unit resolution and yoctomole mass detection limits in a 32-channel system
We report a multiplexed capillary electrophoresis system employing an array of 32 capillaries with a micromachined sheath-flow cuvette as the detection chamber. The sample streams were simultaneously excited with a 473-nm laser beam, and the fluorescence emission was imaged on a CCD camera with a pair of doublet achromat lens. The instrument produced mass detection limits of 380 ± 120 yoctomoles for fluorescein in zone electrophoresis. Capillary isoelectric focusing of fluorescent standards produced peaks with an average width of 0.0029 ± 0.0008 pH. Capillary coating stability limits the reproducibility of the analysis.
- 25 March 2010
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 397 (8) , 3305-3310
Capillary array isoelectric focusing with laser-induced fluorescence detection: milli-pH unit resolution and yoctomole mass detection limits in a 32-channel system
We report a multiplexed capillary electrophoresis system employing an array of 32 capillaries with a micromachined sheath-flow cuvette as the detection chamber. The sample streams were simultaneously excited with a 473-nm laser beam, and the fluorescence emission was imaged on a CCD camera with a pair of doublet achromat lens. The instrument produced mass detection limits of 380 ± 120 yoctomoles for fluorescein in zone electrophoresis. Capillary isoelectric focusing of fluorescent standards produced peaks with an average width of 0.0029 ± 0.0008 pH. Capillary coating stability limits the reproducibility of the analysis.
- 3 March 2010
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 9 (5) , 2412-2421
Proteomic Profiling of Lipopolysaccharide-Activated Macrophages by Isotope Coded Affinity Tagging
Lipopolysaccharide (LPS), a glycolipid component of the outer membranes of Gram-negative bacteria, initiates proinflammatory, proapoptotic, and antiapoptotic pathways upon binding to macrophage TLR4. Macrophages that are exposed to LPS become activated and exhibit altered morphology and response to infection. We performed isotope coded affinity tagging (ICAT), multidimensional liquid chromatography, and mass spectrometry to identify proteins that are differently expressed between naïve and LPS-activated macrophages. We performed replicate ICAT analyses on RAW 264.7 cultured mouse macrophages as well as C57BL/6 bone marrow derived mouse macrophages. We identified and obtained relative abundances for 1064 proteins, of which we identified 36 as having significantly different expression levels upon activation by LPS. We also compared our results with a two color microarray gene expression assay performed by the Institute for Systems Biology and observed ∼75% agreement between mRNA transcription and protein expression regarding up- or down-regulation of gene products. We used Western blot analysis to confirm the findings of ICAT and mRNA for one protein, sequestosome 1, the cellular concentration of which was observed to increase upon activation by LPS.
- 3 March 2010
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 9 (5) , 2412-2421
Proteomic Profiling of Lipopolysaccharide-Activated Macrophages by Isotope Coded Affinity Tagging
Lipopolysaccharide (LPS), a glycolipid component of the outer membranes of Gram-negative bacteria, initiates proinflammatory, proapoptotic, and antiapoptotic pathways upon binding to macrophage TLR4. Macrophages that are exposed to LPS become activated and exhibit altered morphology and response to infection. We performed isotope coded affinity tagging (ICAT), multidimensional liquid chromatography, and mass spectrometry to identify proteins that are differently expressed between naïve and LPS-activated macrophages. We performed replicate ICAT analyses on RAW 264.7 cultured mouse macrophages as well as C57BL/6 bone marrow derived mouse macrophages. We identified and obtained relative abundances for 1064 proteins, of which we identified 36 as having significantly different expression levels upon activation by LPS. We also compared our results with a two color microarray gene expression assay performed by the Institute for Systems Biology and observed ∼75% agreement between mRNA transcription and protein expression regarding up- or down-regulation of gene products. We used Western blot analysis to confirm the findings of ICAT and mRNA for one protein, sequestosome 1, the cellular concentration of which was observed to increase upon activation by LPS.
- 3 December 2009
- Published by Wiley in Electrophoresis
- Vol. 30 (23) , 4071-4074
CE‐MALDI interface based on inkjet technology
An ink jet printer valve and a nozzle were used to deliver matrix and sample from an electrophoresis capillary onto a MALDI plate. The system was evaluated by the separation of a set of standard peptides. That separation generated up to 40 000 theoretical plates in less than 3 min. Detection limits were 500 amol for an ABI TOF‐TOF instrument and 2 fmol for an ABI Q‐TOF instrument. Over 70% coverage was obtained for the tryptic digest of α‐lactalbumin in less than 2.5 min.
- 3 December 2009
- Published by Wiley in Electrophoresis
- Vol. 30 (23) , 4071-4074
CE‐MALDI interface based on inkjet technology
An ink jet printer valve and a nozzle were used to deliver matrix and sample from an electrophoresis capillary onto a MALDI plate. The system was evaluated by the separation of a set of standard peptides. That separation generated up to 40 000 theoretical plates in less than 3 min. Detection limits were 500 amol for an ABI TOF‐TOF instrument and 2 fmol for an ABI Q‐TOF instrument. Over 70% coverage was obtained for the tryptic digest of α‐lactalbumin in less than 2.5 min.