Paul C. Dechow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Paul C. Dechow has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Lynne A. Opperman
Department of Biomedical Sciences, Texas A&M University College of Dentistry, Dallas, Texas
6 shared publications Qian Wang
Department of Biomedical Sciences, Texas A&M University College of Dentistry, Dallas, Texas
5 shared publications- Elias Kontogiorgos
Department of Biomedical Sciences, Texas A&M Health Science Center, Baylor College of Dentistry, Dallas, TX 75246, USA
4 shared publications - Uriel Zapata
Universidad Eafit
3 shared publications - Callum F. Ross
Department of Organismal Biology and Anatomy University of Chicago Chicago Illinois USA
2 shared publications David S. Strait
Department of Anthropology, Washington University in St. Louis, St. Louis, Missouri
2 shared publications
Latest Publications
- Open Access
- 15 November 2016
- Published by Wiley in The Anatomical Record
- Vol. 299 (12) , 1718-1733
Elastic Properties of Chimpanzee Craniofacial Cortical Bone
Relatively few assessments of cranial biomechanics formally take into account variation in the material properties of cranial cortical bone. Our aim was to characterize the elastic properties of chimpanzee craniofacial cortical bone and compare these to the elastic properties of dentate human craniofacial cortical bone. From seven cranial regions, 27 cylindrical samples were harvested from each of five chimpanzee crania. Assuming orthotropy, axes of maximum stiffness in the plane of the cortical plate were derived using modified equations of Hooke's law in a Mathcad program. Consistent orientations among individuals were observed in the zygomatic arch and alveolus. The density of cortical bone showed significant regional variation (P < 0.001). The elastic moduli demonstrated significant differences between sites, and a distinct pattern where E3 > E2 > E1. Shear moduli were significantly different among regions (P < 0.001). The pattern by which chimpanzee cranial cortical bone varies in elastic properties resembled that seen in humans, perhaps suggesting that the elastic properties of craniofacial bone in fossil hominins can be estimated with at least some degree of confidence. Anat Rec, 299:1718–1733, 2016.
- 15 November 2016
- Published by Wiley in The Anatomical Record
- Vol. 299 (12) , 1718-1733
Open AccessElastic Properties of Chimpanzee Craniofacial Cortical Bone
Relatively few assessments of cranial biomechanics formally take into account variation in the material properties of cranial cortical bone. Our aim was to characterize the elastic properties of chimpanzee craniofacial cortical bone and compare these to the elastic properties of dentate human craniofacial cortical bone. From seven cranial regions, 27 cylindrical samples were harvested from each of five chimpanzee crania. Assuming orthotropy, axes of maximum stiffness in the plane of the cortical plate were derived using modified equations of Hooke's law in a Mathcad program. Consistent orientations among individuals were observed in the zygomatic arch and alveolus. The density of cortical bone showed significant regional variation (P < 0.001). The elastic moduli demonstrated significant differences between sites, and a distinct pattern where E3 > E2 > E1. Shear moduli were significantly different among regions (P < 0.001). The pattern by which chimpanzee cranial cortical bone varies in elastic properties resembled that seen in humans, perhaps suggesting that the elastic properties of craniofacial bone in fossil hominins can be estimated with at least some degree of confidence. Anat Rec, 299:1718–1733, 2016.
- 19 September 2014
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 136 (11) , 111011-1110118
Biomechanics of the Canine Mandible During Bone Transport Distraction Osteogenesis
This study compared biomechanical patterns between finite element models (FEMs) and a fresh dog mandible tested under molar and incisal physiological loads in order to clarify the effect of the bone transport distraction osteogenesis (BTDO) surgical process. Three FEMs of dog mandibles were built in order to evaluate the effects of BTDO. The first model evaluated the mandibular response under two physiological loads resembling bite processes. In the second model, a 5.0 cm bone defect was bridged with a bone transport reconstruction plate (BTRP). In the third model, new regenerated bony tissue was incorporated within the defect to mimic the surgical process without the presence of the device. Complementarily, a mandible of a male American foxhound dog was mechanically tested in the laboratory both in the presence and absence of a BTRP, and mechanical responses were measured by attaching rosettes to the bone surface of the mandible to validate the FEM predictions. The relationship between real and predicted values indicates that the stress patterns calculated using FEM are a valid predictor of the biomechanics of the BTDO procedures. The present study provides an interesting correlation between the stiffness of the device and the biomechanical response of the mandible affected for bone transport.
- 19 September 2014
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 136 (11) , 111011-1110118
Biomechanics of the Canine Mandible During Bone Transport Distraction Osteogenesis
This study compared biomechanical patterns between finite element models (FEMs) and a fresh dog mandible tested under molar and incisal physiological loads in order to clarify the effect of the bone transport distraction osteogenesis (BTDO) surgical process. Three FEMs of dog mandibles were built in order to evaluate the effects of BTDO. The first model evaluated the mandibular response under two physiological loads resembling bite processes. In the second model, a 5.0 cm bone defect was bridged with a bone transport reconstruction plate (BTRP). In the third model, new regenerated bony tissue was incorporated within the defect to mimic the surgical process without the presence of the device. Complementarily, a mandible of a male American foxhound dog was mechanically tested in the laboratory both in the presence and absence of a BTRP, and mechanical responses were measured by attaching rosettes to the bone surface of the mandible to validate the FEM predictions. The relationship between real and predicted values indicates that the stress patterns calculated using FEM are a valid predictor of the biomechanics of the BTDO procedures. The present study provides an interesting correlation between the stiffness of the device and the biomechanical response of the mandible affected for bone transport.
- 12 October 2012
- Vol. 27 (5) , 1069-80
Comparison of the effects of phosphate-coated and sandblasted acid-etched titanium implants on osseointegration: a microcomputed tomographic examination in the canine model.
This study tested the effects of phosphate treatment of titanium on bone volume fraction (BV/TV) at 30 to 60 Μm from the implant surface using microcomputed tomography to analyze the mineralized tissue. Electrolytically phosphated (50/100 volts [T1/T2]) or nonphosphated 3.3- X 8-mm titanium implants (C) with sandblasted acid-etched surfaces were placed in 40 mandibular sites in five foxhounds 6 weeks after the extraction of the premolars. After 4 weeks, the animals were sacrificed, and BV/TV was analyzed using microcomputed tomography. The mean BV/TV (± standard deviation) of the control implants was 31.4% ± 15.3% (range, 10.9% to 55.3%). For the T1 implants, a mean BV/TV of 38.4% ± 10.7% (range, 21.6% to 57.3%) was seen, and for T2 implants, the mean BV/TV was 40.3% ± 15.1% (range, 16.5% to 61.1%). Mean BV/TV values for the groups were not significantly different. For all groups (C, T1, and T2), there were no significant differences in BV/TV at the most coronal slices. For all groups, there was a positive slope showing more bone apposition as the slices moved from coronal to apical. The T2 group showed significantly increased mineralized tissue moving from the coronal to the apical section of the implant, compared to the control and T1 implants. Access to better blood supply and bone cells from the marrow spaces in the apical regions may lead to a better trabecular bone response. Increased mineralized tissue apposition may allow for accelerated loading and more predictable implant placement in sites with poor quality bone or patients with compromised bone healing.
- 12 October 2012
- Vol. 27 (5) , 1069-80
Comparison of the effects of phosphate-coated and sandblasted acid-etched titanium implants on osseointegration: a microcomputed tomographic examination in the canine model.
This study tested the effects of phosphate treatment of titanium on bone volume fraction (BV/TV) at 30 to 60 Μm from the implant surface using microcomputed tomography to analyze the mineralized tissue. Electrolytically phosphated (50/100 volts [T1/T2]) or nonphosphated 3.3- X 8-mm titanium implants (C) with sandblasted acid-etched surfaces were placed in 40 mandibular sites in five foxhounds 6 weeks after the extraction of the premolars. After 4 weeks, the animals were sacrificed, and BV/TV was analyzed using microcomputed tomography. The mean BV/TV (± standard deviation) of the control implants was 31.4% ± 15.3% (range, 10.9% to 55.3%). For the T1 implants, a mean BV/TV of 38.4% ± 10.7% (range, 21.6% to 57.3%) was seen, and for T2 implants, the mean BV/TV was 40.3% ± 15.1% (range, 16.5% to 61.1%). Mean BV/TV values for the groups were not significantly different. For all groups (C, T1, and T2), there were no significant differences in BV/TV at the most coronal slices. For all groups, there was a positive slope showing more bone apposition as the slices moved from coronal to apical. The T2 group showed significantly increased mineralized tissue moving from the coronal to the apical section of the implant, compared to the control and T1 implants. Access to better blood supply and bone cells from the marrow spaces in the apical regions may lead to a better trabecular bone response. Increased mineralized tissue apposition may allow for accelerated loading and more predictable implant placement in sites with poor quality bone or patients with compromised bone healing.
- Open Access
- 13 April 2012
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 10 (1) , 72
Engaging basic scientists in translational research: identifying opportunities, overcoming obstacles
This report is based on the Federation of American Societies for Experimental Biology’s symposium, “Engaging basic Scientists in Translational Research: Identifying Opportunities, Overcoming Obstacles,” held in Chevy Chase, MD, March 24–25, 2011. Meeting participants examined the benefits of engaging basic scientists in translational research, the challenges to their participation in translational research, and the roles that research institutions, funding organizations, professional societies, and scientific publishers can play to address these challenges.
- 13 April 2012
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 10 (1) , 72
Open AccessEngaging basic scientists in translational research: identifying opportunities, overcoming obstacles
This report is based on the Federation of American Societies for Experimental Biology’s symposium, “Engaging basic Scientists in Translational Research: Identifying Opportunities, Overcoming Obstacles,” held in Chevy Chase, MD, March 24–25, 2011. Meeting participants examined the benefits of engaging basic scientists in translational research, the challenges to their participation in translational research, and the roles that research institutions, funding organizations, professional societies, and scientific publishers can play to address these challenges.
- 1 April 2012
- Vol. 24 (4) , 99-109
Vacuum-induced Suction Stimulates Increased Numbers of Blood Vessels in Healthy Dog Gingiva.
This study was designed to determine if vacuum-induced suction increased the number of blood vessels in healthy dog gingiva as a prelude to future studies testing vacuum therapy for improving local blood supply and controlling periodontal disease. The buccal gingiva of five dogs was treated with subatmospheric pressure for 5 days, with untreated tissues acting as controls. Biopsies were analyzed for vascular endothelial growth factors (VEGF) and blood vessels were counted. VEGF and vessel numbers were elevated in treatment groups compared to controls (P < 0.05). A single daily application of subatmospheric pressure might be beneficial for healing damaged or diseased gingival tissues. .
- 1 April 2012
- Vol. 24 (4) , 99-109
Vacuum-induced Suction Stimulates Increased Numbers of Blood Vessels in Healthy Dog Gingiva.
This study was designed to determine if vacuum-induced suction increased the number of blood vessels in healthy dog gingiva as a prelude to future studies testing vacuum therapy for improving local blood supply and controlling periodontal disease. The buccal gingiva of five dogs was treated with subatmospheric pressure for 5 days, with untreated tissues acting as controls. Biopsies were analyzed for vascular endothelial growth factors (VEGF) and blood vessels were counted. VEGF and vessel numbers were elevated in treatment groups compared to controls (P < 0.05). A single daily application of subatmospheric pressure might be beneficial for healing damaged or diseased gingival tissues. .
- 31 January 2012
- Published by Elsevier in Journal of Human Evolution
- Vol. 62 (1) , 165-168
Microwear, mechanics and the feeding adaptations of Australopithecus africanus
- 31 January 2012
- Published by Elsevier in Journal of Human Evolution
- Vol. 62 (1) , 165-168
Microwear, mechanics and the feeding adaptations of Australopithecus africanus
- 10 May 2011
- Published by Springer Nature in Calcified Tissue International
- Vol. 89 (1) , 43-52
Three-Dimensional Evaluation of Mandibular Bone Regenerated By Bone Transport Distraction Osteogenesis
The purpose of this study was to evaluate the structure and material properties of native mandibular bone and those of early regenerate bone, produced by bone transport distraction osteogenesis. Ten adult foxhounds were divided into two groups of five animals each. In all animals, a 3- to 4-cm defect was created on one side of the mandible. A bone transport reconstruction plate, consisting of a reconstruction plate with an attached intraoral transport unit, was utilized to stabilize the mandible and regenerate bone at a rate of 1 mm/day. After the distraction period was finished, the animals were killed at 6 and 12 weeks of consolidation. Micro-computed tomography was used to assess the morphometric and structural indices of regenerate bone and matching bone from the unoperated contralateral side. Significant new bone was formed within the defect in the 6- and 12-week groups. Significant differences (P ≤ 0.05) between mandibular regenerated and native bone were found in regard to bone volume fraction, mineral density, bone surface ratio, trabecular thickness, trabecular separation, and connectivity density, which increased from 12 to 18 weeks of consolidation. We showed that regenerated bone is still mineralizing and that native bone appears denser because of a thick outer layer of cortical bone that is not yet formed in the regenerate. However, the regenerate showed a significantly higher number of thicker trabeculae.
- 10 May 2011
- Published by Springer Nature in Calcified Tissue International
- Vol. 89 (1) , 43-52
Three-Dimensional Evaluation of Mandibular Bone Regenerated By Bone Transport Distraction Osteogenesis
The purpose of this study was to evaluate the structure and material properties of native mandibular bone and those of early regenerate bone, produced by bone transport distraction osteogenesis. Ten adult foxhounds were divided into two groups of five animals each. In all animals, a 3- to 4-cm defect was created on one side of the mandible. A bone transport reconstruction plate, consisting of a reconstruction plate with an attached intraoral transport unit, was utilized to stabilize the mandible and regenerate bone at a rate of 1 mm/day. After the distraction period was finished, the animals were killed at 6 and 12 weeks of consolidation. Micro-computed tomography was used to assess the morphometric and structural indices of regenerate bone and matching bone from the unoperated contralateral side. Significant new bone was formed within the defect in the 6- and 12-week groups. Significant differences (P ≤ 0.05) between mandibular regenerated and native bone were found in regard to bone volume fraction, mineral density, bone surface ratio, trabecular thickness, trabecular separation, and connectivity density, which increased from 12 to 18 weeks of consolidation. We showed that regenerated bone is still mineralizing and that native bone appears denser because of a thick outer layer of cortical bone that is not yet formed in the regenerate. However, the regenerate showed a significantly higher number of thicker trabeculae.
- 10 January 2011
- Published by Hindawi Limited in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 5 (7) , 551-559
Biomechanical characteristics of regenerated cortical bone in the canine mandible
To test the mechanical properties of regenerate cortical bone created using mandibular bone transport (MBT) distraction, five adult male American foxhound dogs underwent unilateral distraction of the mandible with a novel MBT device placed to linearly repair a 30–35 mm bone defect. The animals were sacrificed 12 weeks after the beginning of the consolidation period. Fourteen cylindrical specimens were taken from the inner (lingual) and outer (buccal) plates of the reconstructed mandible and 21 control specimens were removed from the contralateral aspect of the mandible. The mechanical properties of the 35 cylindrical cortical bone specimens were assessed by using a non‐destructive pulse ultrasound technique. Results showed that all of the cortical mechanical properties exhibit higher numerical values on the control side than the MBT regenerate side. In addition, both densities and the elastic moduli in the direction of maximum stiffness of the regenerate cortical bone specimens are higher on the lingual side than the buccal side. Interestingly, there is no statistical difference between elastic modulus (E1 and E2) in orthogonal directions throughout the 35 cortical specimens. The data suggest that not only is the regenerate canine cortical bone heterogeneous, but the elastic mechanical properties tend to approximate transverse isotropy at a tissue level, as opposed to control cortical bone, which is orthotropic. In addition, the elastic mechanical properties are higher not only on the control side but also in the lingual anatomical position, suggesting a stress shielding effect from the presence of the reconstruction plate. Copyright © 2011 John Wiley & Sons, Ltd.
- 10 January 2011
- Published by Hindawi Limited in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 5 (7) , 551-559
Biomechanical characteristics of regenerated cortical bone in the canine mandible
To test the mechanical properties of regenerate cortical bone created using mandibular bone transport (MBT) distraction, five adult male American foxhound dogs underwent unilateral distraction of the mandible with a novel MBT device placed to linearly repair a 30–35 mm bone defect. The animals were sacrificed 12 weeks after the beginning of the consolidation period. Fourteen cylindrical specimens were taken from the inner (lingual) and outer (buccal) plates of the reconstructed mandible and 21 control specimens were removed from the contralateral aspect of the mandible. The mechanical properties of the 35 cylindrical cortical bone specimens were assessed by using a non‐destructive pulse ultrasound technique. Results showed that all of the cortical mechanical properties exhibit higher numerical values on the control side than the MBT regenerate side. In addition, both densities and the elastic moduli in the direction of maximum stiffness of the regenerate cortical bone specimens are higher on the lingual side than the buccal side. Interestingly, there is no statistical difference between elastic modulus (E1 and E2) in orthogonal directions throughout the 35 cortical specimens. The data suggest that not only is the regenerate canine cortical bone heterogeneous, but the elastic mechanical properties tend to approximate transverse isotropy at a tissue level, as opposed to control cortical bone, which is orthotropic. In addition, the elastic mechanical properties are higher not only on the control side but also in the lingual anatomical position, suggesting a stress shielding effect from the presence of the reconstruction plate. Copyright © 2011 John Wiley & Sons, Ltd.
- 14 November 2010
- Published by Wiley in Journal of Anatomy
- Vol. 218 (1) , 26-39
Elastic anisotropy and off-axis ultrasonic velocity distribution in human cortical bone
Elastic structure in cortical bone is usually simplified as orthotropic or transversely isotropic, which allows estimates of three-dimensional technical constants from ultrasonic and density measurements. These elastic property estimates can then be used to study phenotypic changes in cortical bone structure and function, and to create finite element models of skeletal structures for studies of organismal variation and functional adaptation. This study examines assumptions of orthotropic or transversely isotropic material structure in cortical bone through the investigation of off-axis ultrasonic velocities in the cortical plane in 10 samples each from a human femur, mandible and cranium. Longitudinal ultrasonic velocities were measured twice through each bone sample by rotating the perimeter of each sample in 1 ° angular intervals between two ultrasonic transducers. The data were fit to sine curves f(x)=(A × sin(x + B) + C) and the goodness of fit was examined. All the data from the femur fit closely with the ideal sine curve model, and all three coefficients were similar among specimens, indicating similar elastic properties, anisotropies and orientations of the axes of maximum stiffness. Off-axis ultrasonic velocities in the mandible largely fit the sine curve model, although there were regional variations in the coefficients. Off-axis ultrasonic velocities from the cranial vault conformed to the sine curve model in some regions but not in others, which shows an irregular and complex pattern. We hypothesize that these variations in ultrasonic velocities reflect variations in the underlying bulk microstructure of the cortical bone, especially in the three-dimensional patterns of osteonal orientation and structure. Elastic property estimates made with ultrasonic techniques are likely valid in the femur and mandible; errors in estimates from cranial bone need to be evaluated regionally. Approximate orthotropic structure in bulk cortical bone specimens should be assessed if ultrasound is used to estimate three-dimensional elastic properties.
- 14 November 2010
- Published by Wiley in Journal of Anatomy
- Vol. 218 (1) , 26-39
Elastic anisotropy and off-axis ultrasonic velocity distribution in human cortical bone
Elastic structure in cortical bone is usually simplified as orthotropic or transversely isotropic, which allows estimates of three-dimensional technical constants from ultrasonic and density measurements. These elastic property estimates can then be used to study phenotypic changes in cortical bone structure and function, and to create finite element models of skeletal structures for studies of organismal variation and functional adaptation. This study examines assumptions of orthotropic or transversely isotropic material structure in cortical bone through the investigation of off-axis ultrasonic velocities in the cortical plane in 10 samples each from a human femur, mandible and cranium. Longitudinal ultrasonic velocities were measured twice through each bone sample by rotating the perimeter of each sample in 1 ° angular intervals between two ultrasonic transducers. The data were fit to sine curves f(x)=(A × sin(x + B) + C) and the goodness of fit was examined. All the data from the femur fit closely with the ideal sine curve model, and all three coefficients were similar among specimens, indicating similar elastic properties, anisotropies and orientations of the axes of maximum stiffness. Off-axis ultrasonic velocities in the mandible largely fit the sine curve model, although there were regional variations in the coefficients. Off-axis ultrasonic velocities from the cranial vault conformed to the sine curve model in some regions but not in others, which shows an irregular and complex pattern. We hypothesize that these variations in ultrasonic velocities reflect variations in the underlying bulk microstructure of the cortical bone, especially in the three-dimensional patterns of osteonal orientation and structure. Elastic property estimates made with ultrasonic techniques are likely valid in the femur and mandible; errors in estimates from cranial bone need to be evaluated regionally. Approximate orthotropic structure in bulk cortical bone specimens should be assessed if ultrasound is used to estimate three-dimensional elastic properties.
- Open Access
- 16 March 2010
- Published by Wiley in The Anatomical Record
- Vol. 293 (4) , 618-629
Edentulation Alters Material Properties of Cortical Bone in the Human Craniofacial Skeleton: Functional Implications for Craniofacial Structure in Primate Evolution
Skeletal adaptations to reduced function are an important source of skeletal variation and may be indicative of environmental pressures that lead to evolutionary changes. Humans serve as a model animal to investigate the effects of loss of craniofacial function through edentulation. In the human maxilla, it is known that edentulation leads to significant changes in skeletal structure such as residual ridge resorption and loss of cortical thickness. However, little is known about changes in bone tissue structure and material properties, which are also important for understanding skeletal mechanics but are often ignored. The aims of this study were to determine cortical material properties in edentulous crania and to evaluate differences with dentate crania and thus examine the effects of loss of function on craniofacial structure. Cortical bone samples from 15 edentulous human skulls were measured for thickness and density. Elastic properties and directions of maximum stiffness were determined by using ultrasonic techniques. These data were compared to those from dentate crania reported in a previous investigation. Cortical bone from all regions of the facial skeleton of edentulous individuals is thinner than in dentate skulls. Elastic and shear moduli, and density are similar or greater in the zygoma and cranial vault of edentulous individuals, whereas these properties are less in the maxilla. Most cortical bone, especially in edentulous maxillae, has reduced directional orientation. The loss of significant occlusal loads following edentulation may contribute to the change in material properties and the loss of orientation over time during the normal process of bone remodeling. These results suggest that area‐specific cortical microstructural changes accompany bone resorption following edentulation. They also suggest that functional forces are important for maintaining bone mass throughout the craniofacial skeleton, even in areas such as the browridges, which have been thought to be little affected by function, because of low in vivo strains found there in several primate studies. Anat Rec, 293:618–629, 2010.
- 16 March 2010
- Published by Wiley in The Anatomical Record
- Vol. 293 (4) , 618-629
Open AccessEdentulation Alters Material Properties of Cortical Bone in the Human Craniofacial Skeleton: Functional Implications for Craniofacial Structure in Primate Evolution
Skeletal adaptations to reduced function are an important source of skeletal variation and may be indicative of environmental pressures that lead to evolutionary changes. Humans serve as a model animal to investigate the effects of loss of craniofacial function through edentulation. In the human maxilla, it is known that edentulation leads to significant changes in skeletal structure such as residual ridge resorption and loss of cortical thickness. However, little is known about changes in bone tissue structure and material properties, which are also important for understanding skeletal mechanics but are often ignored. The aims of this study were to determine cortical material properties in edentulous crania and to evaluate differences with dentate crania and thus examine the effects of loss of function on craniofacial structure. Cortical bone samples from 15 edentulous human skulls were measured for thickness and density. Elastic properties and directions of maximum stiffness were determined by using ultrasonic techniques. These data were compared to those from dentate crania reported in a previous investigation. Cortical bone from all regions of the facial skeleton of edentulous individuals is thinner than in dentate skulls. Elastic and shear moduli, and density are similar or greater in the zygoma and cranial vault of edentulous individuals, whereas these properties are less in the maxilla. Most cortical bone, especially in edentulous maxillae, has reduced directional orientation. The loss of significant occlusal loads following edentulation may contribute to the change in material properties and the loss of orientation over time during the normal process of bone remodeling. These results suggest that area‐specific cortical microstructural changes accompany bone resorption following edentulation. They also suggest that functional forces are important for maintaining bone mass throughout the craniofacial skeleton, even in areas such as the browridges, which have been thought to be little affected by function, because of low in vivo strains found there in several primate studies. Anat Rec, 293:618–629, 2010.