Jeremy P. Loenneke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jeremy P. Loenneke has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Thomas J. Pujol
Department of Health, Human Performance, and Recreation Southeast Missouri State University Cape Girardeau MO USA
11 shared publicationsJacob M. Wilson
Department of Health Sciences and Human Performance University of Tampa Tampa FL USA
10 shared publicationsMichael G. Bemben
Department of Health and Exercise Science University of Oklahoma Norman OK USA
10 shared publicationsChristopher A. Fahs
Department of Health and Exercise Science University of Oklahoma Norman OK USA
9 shared publicationsLindy M. Rossow
Department of Health and Exercise Science University of Oklahoma Norman OK USA
9 shared publicationsTakashi Abe
Department of Health, Exercise Science, and Recreation Management, The University of Mississippi, Oxford, MS
9 shared publications
Latest Publications
- 1 June 2014
- Published by Akademiai Kiado Zrt. in Acta Physiologica Hungarica
- Vol. 101 (2) , 158-166
Blood flow restriction: Effects of cuff type on fatigue and perceptual responses to resistance exercise
Blood flow restriction (BFR) combined with low load resistance training has been shown to result in muscle hypertrophy similar to that observed with higher loads. However, not all studies have found BFR efficacious, possibly due to methodological differences. It is presently unclear whether there are differences between cuffs of similar size (5 cm) but different material (nylon vs. elastic). The purpose was to determine if there are differences in repetitions to fatigue and perceptual ratings of exertion (RPE) and discomfort between narrow elastic and narrow nylon cuffs. Sixteen males and females completed three sets of BFR knee extension exercise in a randomized cross-over design using either elastic or nylon restrictive cuffs applied at the proximal thigh. There were no differences in repetitions to fatigue (marker of blood flow) or perceptual ratings between narrow elastic and narrow nylon cuffs. This data suggests that either elastic or nylon cuffs of the same width should cause similar degrees of BFR at the same pressure during resistance exercise.
- 1 June 2014
- Published by Akademiai Kiado Zrt. in Acta Physiologica Hungarica
- Vol. 101 (2) , 158-166
Blood flow restriction: Effects of cuff type on fatigue and perceptual responses to resistance exercise
Blood flow restriction (BFR) combined with low load resistance training has been shown to result in muscle hypertrophy similar to that observed with higher loads. However, not all studies have found BFR efficacious, possibly due to methodological differences. It is presently unclear whether there are differences between cuffs of similar size (5 cm) but different material (nylon vs. elastic). The purpose was to determine if there are differences in repetitions to fatigue and perceptual ratings of exertion (RPE) and discomfort between narrow elastic and narrow nylon cuffs. Sixteen males and females completed three sets of BFR knee extension exercise in a randomized cross-over design using either elastic or nylon restrictive cuffs applied at the proximal thigh. There were no differences in repetitions to fatigue (marker of blood flow) or perceptual ratings between narrow elastic and narrow nylon cuffs. This data suggests that either elastic or nylon cuffs of the same width should cause similar degrees of BFR at the same pressure during resistance exercise.
- 1 May 2014
- Published by Elsevier in Medical Hypotheses
- Vol. 82 (5) , 623-626
Blood flow restriction pressure recommendations: The hormesis hypothesis
- 1 May 2014
- Published by Elsevier in Medical Hypotheses
- Vol. 82 (5) , 623-626
Blood flow restriction pressure recommendations: The hormesis hypothesis
- 1 April 2014
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 34 (5) , 410-412
Validity of a portable computer‐based ultrasound system for estimating adipose tissue in female gymnasts
Summary: The aim of this investigation was to determine the validity of a portable ultrasound instrument for estimating adipose tissue (AT%) compared to dual‐energyX‐ray absorptiometry (DXA) in female collegiate gymnasts. Participants had their measurements taken in the following order: urine‐specific gravity, body mass, height, ultrasound determinedAT% (1‐site and 3‐site) andDXAdeterminedAT%. The current pilot study found significant differences between estimates ofAT% (P < 0·001). Pearson's correlations betweenDXAand 1‐site and 3‐site estimates werer = 0·786 andr = 0·753, respectively. The standard error of the estimate betweenDXAand 1‐site and 3‐site estimates was 3·6% and 3·9%, respectively. However, the average deviation of individual scores from the line of identity was 6·7% for the 1‐site and 4·9% for the 3‐site, when compared with theDXAestimate. The results of this preliminary study found that the portable ultrasound was not a valid estimate ofAT% when compared with theDXAestimate in female collegiate gymnasts.
- 1 April 2014
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 34 (5) , 410-412
Validity of a portable computer‐based ultrasound system for estimating adipose tissue in female gymnasts
Summary: The aim of this investigation was to determine the validity of a portable ultrasound instrument for estimating adipose tissue (AT%) compared to dual‐energyX‐ray absorptiometry (DXA) in female collegiate gymnasts. Participants had their measurements taken in the following order: urine‐specific gravity, body mass, height, ultrasound determinedAT% (1‐site and 3‐site) andDXAdeterminedAT%. The current pilot study found significant differences between estimates ofAT% (P < 0·001). Pearson's correlations betweenDXAand 1‐site and 3‐site estimates werer = 0·786 andr = 0·753, respectively. The standard error of the estimate betweenDXAand 1‐site and 3‐site estimates was 3·6% and 3·9%, respectively. However, the average deviation of individual scores from the line of identity was 6·7% for the 1‐site and 4·9% for the 3‐site, when compared with theDXAestimate. The results of this preliminary study found that the portable ultrasound was not a valid estimate ofAT% when compared with theDXAestimate in female collegiate gymnasts.
- 20 March 2014
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 24 (6) , e415-422
Does blood flow restriction result in skeletal muscle damage? A critical review of available evidence
Blood flow restriction (BFR) alone or in combination with exercise has been shown to result in muscle hypertrophy and strength gain across a variety of populations. Although there are numerous studies in the literature showing beneficial muscular effects following the application of BFR, questions have been raised over whether BFR may lead to or even increase the incidence of muscle damage. The purpose of this review is to examine the proposed mechanisms behind muscle damage and critically review the available BFR literature. The available evidence does not support the hypothesis that BFR in combination with low‐intensity exercise increases the incidence of muscle damage. Instead, the available literature suggests that minimal to no muscle damage is occurring with this type of exercise. This conclusion is drawn from the following observations: (a) no prolonged decrements in muscle function; (b) no prolonged muscle swelling; (c) muscle soreness ratings similar to a submaximal low load control; and (d) no elevation in blood biomarkers of muscle damage.
- 20 March 2014
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 24 (6) , e415-422
Does blood flow restriction result in skeletal muscle damage? A critical review of available evidence
Blood flow restriction (BFR) alone or in combination with exercise has been shown to result in muscle hypertrophy and strength gain across a variety of populations. Although there are numerous studies in the literature showing beneficial muscular effects following the application of BFR, questions have been raised over whether BFR may lead to or even increase the incidence of muscle damage. The purpose of this review is to examine the proposed mechanisms behind muscle damage and critically review the available BFR literature. The available evidence does not support the hypothesis that BFR in combination with low‐intensity exercise increases the incidence of muscle damage. Instead, the available literature suggests that minimal to no muscle damage is occurring with this type of exercise. This conclusion is drawn from the following observations: (a) no prolonged decrements in muscle function; (b) no prolonged muscle swelling; (c) muscle soreness ratings similar to a submaximal low load control; and (d) no elevation in blood biomarkers of muscle damage.
- 1 October 2013
- Published by SAGE Publications in The Journal of Alternative and Complementary Medicine
- Vol. 19 (10) , 843-844
The Application of Blood Flow Restriction Training into Western Medicine: Isn't It About Time?
- 1 October 2013
- Published by SAGE Publications in The Journal of Alternative and Complementary Medicine
- Vol. 19 (10) , 843-844
The Application of Blood Flow Restriction Training into Western Medicine: Isn't It About Time?
- 1 August 2013
- Vol. 53 (4) , 409-14
Relationship between lifting performance and skeletal muscle mass in elite powerlifters.
Aim of the study was to examine the relationship between whole body skeletal muscle mass (SMM) and powerlifting performance in elite powerlifters. Twenty elite male powerlifters, including 4 world champions, volunteered. Muscle thickness (MTH) and subcutaneous fat thickness (FTH) were measured by ultrasound at 9 sites on the anterior and posterior aspects of the body. FTH was used to estimate body fat and fat-free mass and SMM was estimated from ultrasound-derived prediction equations. Best lifting performance in the squat (SQ), bench press (BP), and dead lift (DL) was recorded from competition performance. Significant strong correlations (P<0.01) were observed between absolute and relative (divided by height) SMM and performance of the SQ (r=0.93 and r=0.94, respectively), BP (r=0.88 and r=0.87), and DL (r=0.84 and r=0.85). Relative lifting performance to SMM for squat (SQ/SMM ratio) and bench press (BP/SMM ratio) were constant throughout a wide range of weight classes (56kg-145kg) and there were no significant correlation between the SMM and those performances (r=0.21 for SQ and r=0.12 for BP). However, the DL/SMM ratio was negatively correlated to DL performance (r=-0.47, P<0.05). SMM is a good predictor of powerlifting performance throughout all weight classes.
- 1 August 2013
- Vol. 53 (4) , 409-14
Relationship between lifting performance and skeletal muscle mass in elite powerlifters.
Aim of the study was to examine the relationship between whole body skeletal muscle mass (SMM) and powerlifting performance in elite powerlifters. Twenty elite male powerlifters, including 4 world champions, volunteered. Muscle thickness (MTH) and subcutaneous fat thickness (FTH) were measured by ultrasound at 9 sites on the anterior and posterior aspects of the body. FTH was used to estimate body fat and fat-free mass and SMM was estimated from ultrasound-derived prediction equations. Best lifting performance in the squat (SQ), bench press (BP), and dead lift (DL) was recorded from competition performance. Significant strong correlations (P<0.01) were observed between absolute and relative (divided by height) SMM and performance of the SQ (r=0.93 and r=0.94, respectively), BP (r=0.88 and r=0.87), and DL (r=0.84 and r=0.85). Relative lifting performance to SMM for squat (SQ/SMM ratio) and bench press (BP/SMM ratio) were constant throughout a wide range of weight classes (56kg-145kg) and there were no significant correlation between the SMM and those performances (r=0.21 for SQ and r=0.12 for BP). However, the DL/SMM ratio was negatively correlated to DL performance (r=-0.47, P<0.05). SMM is a good predictor of powerlifting performance throughout all weight classes.
- 24 July 2013
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 34 (2) , 159-162
Validity and reliability of an ultrasound system for estimating adipose tissue
Summary: When health professionals measure the fitness levels of clients, body composition is usually estimated. In field settings, body composition is commonly estimated with skinfolds or bioelectrical impedance analysis. Recently, a portable ultrasound device has been manufactured to estimate what percentage of body mass is composed of adipose tissue (AT%). A reported advantage of using ultrasound is that inter‐ and intrarater variations may be minimized when compared with the skinfold technique. Therefore, the purpose of this pilot study was twofold; 1) to determine the validity of a portable ultrasound device compared with skinfolds and 2) determine the reliability of the portable ultrasound device. Participants had their measurements taken in the following order: urine specific gravity, body mass, height, skinfolds and ultrasound determined. Participants had their urine specific gravity and ultrasound determined AT% estimates measured again 48 h later. The current pilot study found that the ultrasound was not a valid estimate of AT% when compared with the skinfold estimate (TE > 4%). In addition, the 1‐site estimate from the ultrasound was more reliable than the 3‐site estimate of AT%. These data are of importance to practitioners because it demonstrates that while the ultrasound is not a valid estimate compared with skinfolds, the 1‐site estimate may be able to track changes in AT% over time, making the ultrasound an option for assessing changes in body composition.
- 24 July 2013
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 34 (2) , 159-162
Validity and reliability of an ultrasound system for estimating adipose tissue
Summary: When health professionals measure the fitness levels of clients, body composition is usually estimated. In field settings, body composition is commonly estimated with skinfolds or bioelectrical impedance analysis. Recently, a portable ultrasound device has been manufactured to estimate what percentage of body mass is composed of adipose tissue (AT%). A reported advantage of using ultrasound is that inter‐ and intrarater variations may be minimized when compared with the skinfold technique. Therefore, the purpose of this pilot study was twofold; 1) to determine the validity of a portable ultrasound device compared with skinfolds and 2) determine the reliability of the portable ultrasound device. Participants had their measurements taken in the following order: urine specific gravity, body mass, height, skinfolds and ultrasound determined. Participants had their urine specific gravity and ultrasound determined AT% estimates measured again 48 h later. The current pilot study found that the ultrasound was not a valid estimate of AT% when compared with the skinfold estimate (TE > 4%). In addition, the 1‐site estimate from the ultrasound was more reliable than the 3‐site estimate of AT%. These data are of importance to practitioners because it demonstrates that while the ultrasound is not a valid estimate compared with skinfolds, the 1‐site estimate may be able to track changes in AT% over time, making the ultrasound an option for assessing changes in body composition.
- 18 June 2013
- Published by Taylor & Francis in Research in Sports Medicine
- Vol. 21 (3) , 286-291
Accuracy of Field Methods in Assessing Body Fat in Collegiate Baseball Players
When assessing the fitness levels of athletes, body composition is usually estimated, as it may play a role in athletic performance. Therefore, the purpose of this study was to determine the validity of bioelectrical impedance analysis (BIA) and skinfold (SKF) methods compared with dual-energy X-ray absorptiometry (DXA) for estimating percent body fat (%BF) in Division 1 collegiate baseball players (n = 35). The results of this study indicate that the field methods investigated were not valid compared with DXA for estimating %BF. In conclusion, this study does not support the use of the TBF-350, HBF-306, HBF-500, or SKF thickness for estimating %BF in collegiate baseball players. The reliability of these BIA devices remains unknown; therefore, it is currently uncertain if they may be used to track changes over time.
- 18 June 2013
- Published by Taylor & Francis in Research in Sports Medicine
- Vol. 21 (3) , 286-291
Accuracy of Field Methods in Assessing Body Fat in Collegiate Baseball Players
When assessing the fitness levels of athletes, body composition is usually estimated, as it may play a role in athletic performance. Therefore, the purpose of this study was to determine the validity of bioelectrical impedance analysis (BIA) and skinfold (SKF) methods compared with dual-energy X-ray absorptiometry (DXA) for estimating percent body fat (%BF) in Division 1 collegiate baseball players (n = 35). The results of this study indicate that the field methods investigated were not valid compared with DXA for estimating %BF. In conclusion, this study does not support the use of the TBF-350, HBF-306, HBF-500, or SKF thickness for estimating %BF in collegiate baseball players. The reliability of these BIA devices remains unknown; therefore, it is currently uncertain if they may be used to track changes over time.
- 7 June 2013
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 34 (1) , 77-81
Hypertension risk: exercise is medicine* for most but not all
Summary: Hypertension is a risk factor for heart disease, and chronic exercise is recognized as a method for reducing resting blood pressure. Recent studies report that while exercise may benefit the majority of the population, the blood pressure adaptation is not always uniform; some individuals have an adverse blood pressure response to chronic aerobic exercise programmes. The purpose of this study was to examine the individual changes in resting blood pressure in response to exercise training regimens aimed at increasing muscle mass and strength. We have also included exercise (resistance and aerobic) in combination with blood flow restriction (BFR). Of 74 individuals, 11% had an increased risk, 16% had a decreased risk and 73% had no change in risk classification following exercise. The statistical analysis found that the group that decreased risk with exercise tended to have higher baseline levels of blood pressure. However, there were little baseline differences between the group that increased risk or the group that had no change in risk, suggesting that starting values may not necessarily determine who will see a beneficial response. In conclusion, the blood pressure adaptation to resistance training and exercise with BFR is not homogeneous with some participants increasing, decreasing or staying in the same risk category following an exercise intervention. These are important findings as they would not have been noted or discussed when looking only at the group means. Future research may identify molecular predictors so that individuals at risk for adverse events can be identified prior to exercise.
- 7 June 2013
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 34 (1) , 77-81
Hypertension risk: exercise is medicine* for most but not all
Summary: Hypertension is a risk factor for heart disease, and chronic exercise is recognized as a method for reducing resting blood pressure. Recent studies report that while exercise may benefit the majority of the population, the blood pressure adaptation is not always uniform; some individuals have an adverse blood pressure response to chronic aerobic exercise programmes. The purpose of this study was to examine the individual changes in resting blood pressure in response to exercise training regimens aimed at increasing muscle mass and strength. We have also included exercise (resistance and aerobic) in combination with blood flow restriction (BFR). Of 74 individuals, 11% had an increased risk, 16% had a decreased risk and 73% had no change in risk classification following exercise. The statistical analysis found that the group that decreased risk with exercise tended to have higher baseline levels of blood pressure. However, there were little baseline differences between the group that increased risk or the group that had no change in risk, suggesting that starting values may not necessarily determine who will see a beneficial response. In conclusion, the blood pressure adaptation to resistance training and exercise with BFR is not homogeneous with some participants increasing, decreasing or staying in the same risk category following an exercise intervention. These are important findings as they would not have been noted or discussed when looking only at the group means. Future research may identify molecular predictors so that individuals at risk for adverse events can be identified prior to exercise.
- 3 May 2013
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 33 (5) , 405-408
Reliability of field methods for estimating body fat
Summary: When health professionals measure the fitness levels of clients, body composition is usually estimated. In practice, the reliability of the measurement may be more important than the actual validity, as reliability determines how much change is needed to be considered meaningful. Therefore, the purpose of this study was to determine the reliability of two bioelectrical impedance analysis (BIA) devices (in athlete and non‐athlete mode) and compare that to 3‐site skinfold (SKF) readings. Twenty‐one college students attended the laboratory on two occasions and had their measurements taken in the following order: body mass, height, SKF, Tanita body fat‐350 (BF‐350) and Omron HBF‐306C. There were no significant pairwise differences between Visit 1 and Visit 2 for any of the estimates (P>0·05). The Pearson product correlations ranged from r = 0·933 for HBF‐350 in the athlete mode (A) to r = 0·994 for SKF. The ICC's ranged from 0·93 for HBF‐350(A) to 0·992 for SKF, and the MD's ranged from 1·8% for SKF to 5·1% for BF‐350(A). The current study found that SKF and HBF‐306C(A) were the most reliable (<2%) methods of estimating BF%, with the other methods (BF‐350, BF‐350(A), HBF‐306C) producing minimal differences greater than 2%. In conclusion, the SKF method presented with the best reliability because of its low minimal difference, suggesting this method may be the best field method to track changes over time if you have an experienced tester. However, if technical error is a concern, the practitioner may use the HBF‐306C(A) because it had a minimal difference value comparable to SKF.
- 3 May 2013
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 33 (5) , 405-408
Reliability of field methods for estimating body fat
Summary: When health professionals measure the fitness levels of clients, body composition is usually estimated. In practice, the reliability of the measurement may be more important than the actual validity, as reliability determines how much change is needed to be considered meaningful. Therefore, the purpose of this study was to determine the reliability of two bioelectrical impedance analysis (BIA) devices (in athlete and non‐athlete mode) and compare that to 3‐site skinfold (SKF) readings. Twenty‐one college students attended the laboratory on two occasions and had their measurements taken in the following order: body mass, height, SKF, Tanita body fat‐350 (BF‐350) and Omron HBF‐306C. There were no significant pairwise differences between Visit 1 and Visit 2 for any of the estimates (P>0·05). The Pearson product correlations ranged from r = 0·933 for HBF‐350 in the athlete mode (A) to r = 0·994 for SKF. The ICC's ranged from 0·93 for HBF‐350(A) to 0·992 for SKF, and the MD's ranged from 1·8% for SKF to 5·1% for BF‐350(A). The current study found that SKF and HBF‐306C(A) were the most reliable (<2%) methods of estimating BF%, with the other methods (BF‐350, BF‐350(A), HBF‐306C) producing minimal differences greater than 2%. In conclusion, the SKF method presented with the best reliability because of its low minimal difference, suggesting this method may be the best field method to track changes over time if you have an experienced tester. However, if technical error is a concern, the practitioner may use the HBF‐306C(A) because it had a minimal difference value comparable to SKF.